Skip to main content
WireAndSun
Calculators
CEC PV Module

United Renewable Energy Co Ltd F7M320H7G-BB — CEC Solar Module Specifications

Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd F7M320H7G-BB is a 320.0 W STC (295.8 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 19.03% efficiency, 40.2 V Voc at 25 C, and 44.0 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
320.0 W
PTC Wattage
295.8 W
Voc @ 25C
40.2 V
Efficiency
19.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd F7M320H7G-BB Compare Against Peer CEC Listings?

How United Renewable Energy Co Ltd United Renewable Energy Co Ltd F7M320H7G-BB handles rooftop heat (295.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, United Renewable Energy Co Ltd F7M320H7G-BB exhibits 10.17 A short-circuit current, requiring a 15.87 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #14,944 of 21,677 (90.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 42.0 m2 for an 8 kW system (32 panels for 10 kW). Mid-range 40.2 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does United Renewable Energy Co Ltd F7M320H7G-BB Fall Across Listed CEC Models?

Where United Renewable Energy Co Ltd F7M320H7G-BB (320.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd F7M320H7G-BB (320.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 320.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd F7M320H7G-BB?

Percentile placement of United Renewable Energy Co Ltd F7M320H7G-BB across power density (190.4 W/m2), thermal retention, and nameplate STC wattage.

United Renewable Energy Co Ltd F7M320H7G-BB Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd F7M320H7G-BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage320.0 WPTC/STC Retention92.4%Module Efficiency19.03%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F7M320H7G-BB?

Four critical engineering numbers homeowners and solar installers check first when reviewing United Renewable Energy Co Ltd F7M320H7G-BB specifications.

Rank #14,944 / 21,677

320.0 W STC · Higher Than 29.0%

320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,371

19.03% Aperture Efficiency

Power density 190.4 W/m2 (0.88 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.0 V at -10 C (572.0 V string) and 45.08 V at -20 C (13 max).

8 kW Reference Array

25 Panels = 8,000 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,395 W PTC; NEC 690.8 OCPD floor is 15.87 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.2 * (1 + (-0.27/100) * (-10 - 25)) = 44.0 V | OCPD = 1.56 * 10.17 = 15.87 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F7M320H7G-BB: Voc=40.2 V, beta_Voc=-0.27%/C, Isc=10.17 A, STC=320.0 W, Area=1.681 m2.

Result: 13 panels max on 600 V (572.0 V); 25 panels for 8 kW (452 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd F7M320H7G-BB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for United Renewable Energy Co Ltd F7M320H7G-BB.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd F7M320H7G-BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 320.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 295.8 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.17 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.3 V / 9.61 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.27 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.03% (1.681 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many United Renewable Energy Co Ltd F7M320H7G-BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using United Renewable Energy Co Ltd F7M320H7G-BB (320.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.08 kW 344 sq ft $1,522 $2,573
8 kW Class 25 8.0 kW 452 sq ft $2,002 $3,386
10 kW Class 32 10.24 kW 579 sq ft $2,563 $4,334

Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

All closely matched United Renewable Energy Co Ltd wattages and cosmetic trims sharing the United Renewable Energy Co Ltd F7M320H7G-BB architecture.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd F7M320H7G-BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
United Renewable Energy Co Ltd F7M315H7G-BB 315.0 W 291.1 W 39.9 V 33.1 V 18.74%
United Renewable Energy Co Ltd F7M320H7G-BB 320.0 W 295.8 W 40.2 V 33.3 V 19.03%

How Many United Renewable Energy Co Ltd F7M320H7G-BB Modules Fit in a Cold-Weather String?

Maximum series module counts for United Renewable Energy Co Ltd F7M320H7G-BB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.2V and beta_Voc=-0.27%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.08 V 13 panels 586.0 V 22 panels
-10 C (14 F) 44.0 V 13 panels 572.0 V 22 panels
0 C (32 F) 42.91 V 13 panels 557.8 V 23 panels
25 C (77 F STC) 40.2 V 14 panels 562.8 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F7M320H7G-BB?

Alternative CEC solar modules from competing brands near United Renewable Energy Co Ltd F7M320H7G-BB (320.0 W), including Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W
Dehui Solar Power (Vietnam) CoLtd
320.0 W Tie (0 W) 40.2 V 19.88% 92.9%
GCL System Integration Technology Co Ltd GCL-M6/60320
GCL System Integration Technology Co Ltd
320.0 W Tie (0 W) 40.3 V 19.63% 91.3%
CSI Solar Co Ltd CS3K-320MS
CSI Solar Co Ltd
320.0 W Tie (0 W) 40.1 V 20.0% 93.2%
Aptos Solar Technology LLC DNA-120-MF23-320W {Blk}
Aptos Solar Technology LLC
320.0 W Tie (0 W) 39.92 V 18.96% 90.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F7M320H7G-BB?

Evaluate United Renewable Energy Co Ltd F7M320H7G-BB (320.0 W STC, 40.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F7M320H7G-BB reaches 45.08 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 452 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (452 sq ft).
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F7M320H7G-BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd F7M320H7G-BB 8 kW Residential Fit

Needs 25 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 295.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd F7M320H7G-BB by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is United Renewable Energy Co Ltd F7M320H7G-BB PTC wattage (295.8 W) lower than STC (320.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 295.8 W PTC (92.4% retention) across United Renewable Energy Co Ltd F7M320H7G-BB's 1.681 m2 aperture.

Who should skip United Renewable Energy Co Ltd F7M320H7G-BB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 25 United Renewable Energy Co Ltd F7M320H7G-BB panels (452 sq ft) leave unusable roof gaps vs. Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W.

What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd F7M320H7G-BB?

On 1,000 V commercial inverters at -10 C (44.0 V cold Voc), United Renewable Energy Co Ltd F7M320H7G-BB fits up to 22 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.