United Renewable Energy Co Ltd F7K385H8G is a 385.0 W STC (356.4 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.35% efficiency, 48.4 V Voc at 25 C, and 52.79 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 385.0 W
- PTC Wattage
- 356.4 W
- Voc @ 25C
- 48.4 V
- Efficiency
- 19.35%
How Does United Renewable Energy Co Ltd F7K385H8G Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for United Renewable Energy Co Ltd F7K385H8G (Mono-c-Si) residential solar systems.
United Renewable Energy Co Ltd F7K385H8G delivers 193.5 W/m2 (0.56 percentage points below 19.91% CEC median) and strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (450 sq ft). At -4 F (-20 C), string voltage climbs to 54.04 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Boviet Solar Technology Co Ltd BVM6612M-385L-H (385.0 W).
Where Does United Renewable Energy Co Ltd F7K385H8G Fall Across Listed CEC Models?
Comparison of United Renewable Energy Co Ltd F7K385H8G (385.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define United Renewable Energy Co Ltd F7K385H8G?
Relative ranking of United Renewable Energy Co Ltd F7K385H8G across nameplate watts, 92.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F7K385H8G?
Summary of United Renewable Energy Co Ltd F7K385H8G output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.
385.0 W STC · Higher Than 49.1%
385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.
19.35% Aperture Efficiency
Power density 193.5 W/m2 (0.56 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.79 V at -10 C (580.7 V string) and 54.04 V at -20 C (11 max).
21 Panels = 8,085 W STC
Occupies 41.8 m2 (450 sq ft) producing 7,484 W PTC; NEC 690.8 OCPD floor is 15.79 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.4 * (1 + (-0.259/100) * (-10 - 25)) = 52.79 V | OCPD = 1.56 * 10.12 = 15.79 A
Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F7K385H8G: Voc=48.4 V, beta_Voc=-0.259%/C, Isc=10.12 A, STC=385.0 W, Area=1.99 m2.
Result: 11 panels max on 600 V (580.7 V); 21 panels for 8 kW (450 sq ft).
What Are the Published CEC Specifications for United Renewable Energy Co Ltd F7K385H8G?
Complete CEC test sheet for United Renewable Energy Co Ltd F7K385H8G including Isc (10.12 A), Voc (48.4 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 356.4 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.12 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.2 V / 9.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.259 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.35% (1.99 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many United Renewable Energy Co Ltd F7K385H8G Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using United Renewable Energy Co Ltd F7K385H8G.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.16 kW | 343 sq ft | $1,542 | $2,607 |
| 8 kW Class | 21 | 8.09 kW | 450 sq ft | $2,025 | $3,424 |
| 10 kW Class | 26 | 10.01 kW | 557 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?
Related United Renewable Energy Co Ltd power steps and black/silver trims consolidated into this United Renewable Energy Co Ltd F7K385H8G series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| United Renewable Energy Co Ltd F7K375H8G | 375.0 W | 346.9 W | 47.8 V | 39.6 V | 18.84% |
| United Renewable Energy Co Ltd F7K380H8G | 380.0 W | 351.7 W | 48.1 V | 39.9 V | 19.1% |
| United Renewable Energy Co Ltd F7K385H8G | 385.0 W | 356.4 W | 48.4 V | 40.2 V | 19.35% |
| United Renewable Energy Co Ltd F7K390H8G | 390.0 W | 361.2 W | 48.5 V | 40.3 V | 19.6% |
| United Renewable Energy Co Ltd F7K395H8G | 395.0 W | 365.9 W | 48.7 V | 40.5 V | 19.85% |
How Many United Renewable Energy Co Ltd F7K385H8G Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for United Renewable Energy Co Ltd F7K385H8G (48.4 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.04 V | 11 panels | 594.4 V | 18 panels |
| -10 C (14 F) | 52.79 V | 11 panels | 580.7 V | 18 panels |
| 0 C (32 F) | 51.53 V | 11 panels | 566.8 V | 19 panels |
| 25 C (77 F STC) | 48.4 V | 12 panels | 580.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F7K385H8G?
Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6612M-385L-H (385.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-385L-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.45 V | 18.97% | 93.5% |
| Boviet Solar Technology Co Ltd BVM6612M-385-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-385-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F7K385H8G?
Evaluate United Renewable Energy Co Ltd F7K385H8G (385.0 W STC, 48.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F7K385H8G reaches 54.04 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 450 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (450 sq ft).
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F7K385H8G carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
United Renewable Energy Co Ltd F7K385H8G 8 kW Residential Fit
Needs 21 modules (450 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-385L-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 356.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for United Renewable Energy Co Ltd F7K385H8G by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many United Renewable Energy Co Ltd F7K385H8G panels fit on a 600 V winter solar string?
At -10 C (14 F), United Renewable Energy Co Ltd F7K385H8G cold Voc rises from 48.4 V to 52.79 V (beta_Voc -0.259%/C), capping a 600 V string at 11 panels (580.7 V).
How much roof area does an 8 kW array of United Renewable Energy Co Ltd F7K385H8G need?
An 8 kW DC system uses 21 United Renewable Energy Co Ltd F7K385H8G modules (8,085 W STC / 7,484 W PTC), covering roughly 450 sq ft and saving ~$2,025/yr at 18.54 c/kWh.
How does United Renewable Energy Co Ltd F7K385H8G compare against Boviet Solar Technology Co Ltd BVM6612M-385L-H?
United Renewable Energy Co Ltd F7K385H8G outputs 385.0 W STC (48.4 V Voc, rank #10,723 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-385L-H delivers 385.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)