Skip to main content
WireAndSun
Calculators
CEC PV Module

United Renewable Energy Co Ltd F6E335H4F — CEC Solar Module Specifications

Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd F6E335H4F is a 335.0 W STC (302.7 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.45% efficiency, 46.8 V Voc at 25 C, and 52.86 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
302.7 W
Voc @ 25C
46.8 V
Efficiency
17.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd F6E335H4F Compare Against Peer CEC Listings?

How United Renewable Energy Co Ltd United Renewable Energy Co Ltd F6E335H4F handles rooftop heat (302.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, United Renewable Energy Co Ltd F6E335H4F exhibits 9.3 A short-circuit current, requiring a 14.51 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #13,844 of 21,677 (56.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 46.1 m2 for an 8 kW system (30 panels for 10 kW). Mid-range 46.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does United Renewable Energy Co Ltd F6E335H4F Fall Across Listed CEC Models?

Where United Renewable Energy Co Ltd F6E335H4F (335.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd F6E335H4F (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 335.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd F6E335H4F?

Percentile placement of United Renewable Energy Co Ltd F6E335H4F across power density (174.5 W/m2), thermal retention, and nameplate STC wattage.

United Renewable Energy Co Ltd F6E335H4F Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd F6E335H4F wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention90.4%Module Efficiency17.45%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F6E335H4F?

Four critical engineering numbers homeowners and solar installers check first when reviewing United Renewable Energy Co Ltd F6E335H4F specifications.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,846

17.45% Aperture Efficiency

Power density 174.5 W/m2 (2.46 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.86 V at -10 C (581.5 V string) and 54.59 V at -20 C (10 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 46.1 m2 (496 sq ft) producing 7,265 W PTC; NEC 690.8 OCPD floor is 14.51 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.8 * (1 + (-0.37/100) * (-10 - 25)) = 52.86 V | OCPD = 1.56 * 9.3 = 14.51 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F6E335H4F: Voc=46.8 V, beta_Voc=-0.37%/C, Isc=9.3 A, STC=335.0 W, Area=1.92 m2.

Result: 11 panels max on 600 V (581.5 V); 24 panels for 8 kW (496 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd F6E335H4F?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for United Renewable Energy Co Ltd F6E335H4F.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd F6E335H4F.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 302.7 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.3 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.1 V / 8.8 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.37 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.45% (1.92 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many United Renewable Energy Co Ltd F6E335H4F Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using United Renewable Energy Co Ltd F6E335H4F (335.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 372 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 496 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 620 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

All closely matched United Renewable Energy Co Ltd wattages and cosmetic trims sharing the United Renewable Energy Co Ltd F6E335H4F architecture.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd F6E335H4F wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
United Renewable Energy Co Ltd F6E325H4F 325.0 W 293.4 W 46.6 V 37.8 V 16.93%
United Renewable Energy Co Ltd F6E330H4F 330.0 W 298.0 W 46.7 V 37.95 V 17.19%
United Renewable Energy Co Ltd F6E335H4F 335.0 W 302.7 W 46.8 V 38.1 V 17.45%
United Renewable Energy Co Ltd F6E340H4F 340.0 W 309.6 W 46.9 V 38.25 V 17.71%
United Renewable Energy Co Ltd F6E345H4F 345.0 W 314.3 W 47.0 V 38.55 V 17.97%

How Many United Renewable Energy Co Ltd F6E335H4F Modules Fit in a Cold-Weather String?

Maximum series module counts for United Renewable Energy Co Ltd F6E335H4F from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.8V and beta_Voc=-0.37%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.59 V 10 panels 545.9 V 18 panels
-10 C (14 F) 52.86 V 11 panels 581.5 V 18 panels
0 C (32 F) 51.13 V 11 panels 562.4 V 19 panels
25 C (77 F STC) 46.8 V 12 panels 561.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F6E335H4F?

Alternative CEC solar modules from competing brands near United Renewable Energy Co Ltd F6E335H4F (335.0 W), including Bluesun Solar Energy Tech CoLtd BSM335P-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM335P-72
Bluesun Solar Energy Tech CoLtd
335.0 W Tie (0 W) 46.76 V 17.29% 91.4%
Centrosolar America EM72 335BW
Centrosolar America
335.0 W Tie (0 W) 46.75 V 17.42% 91.4%
Centrosolar America EM72 335SW
Centrosolar America
335.0 W Tie (0 W) 46.75 V 17.42% 91.4%
Auxin Solar AXN6M612T335
Auxin Solar
335.0 W Tie (0 W) 47.04 V 17.26% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F6E335H4F?

Evaluate United Renewable Energy Co Ltd F6E335H4F (335.0 W STC, 46.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F6E335H4F reaches 54.59 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 496 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (496 sq ft).
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F6E335H4F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd F6E335H4F 8 kW Residential Fit

Needs 24 modules (496 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM335P-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 302.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd F6E335H4F by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is United Renewable Energy Co Ltd F6E335H4F PTC wattage (302.7 W) lower than STC (335.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 302.7 W PTC (90.4% retention) across United Renewable Energy Co Ltd F6E335H4F's 1.92 m2 aperture.

Who should skip United Renewable Energy Co Ltd F6E335H4F on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 United Renewable Energy Co Ltd F6E335H4F panels (496 sq ft) leave unusable roof gaps vs. Bluesun Solar Energy Tech CoLtd BSM335P-72.

What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd F6E335H4F?

On 1,000 V commercial inverters at -10 C (52.86 V cold Voc), United Renewable Energy Co Ltd F6E335H4F fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.