Skip to main content
WireAndSun
Calculators
CEC PV Module

United Renewable Energy Co Ltd F6E315H4A — CEC Solar Module Specifications

Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd F6E315H4A is a 315.0 W STC (287.3 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.24% efficiency, 45.4 V Voc at 25 C, and 50.47 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
287.3 W
Voc @ 25C
45.4 V
Efficiency
16.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd F6E315H4A Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for United Renewable Energy Co Ltd F6E315H4A (Multi-c-Si) residential solar systems.

United Renewable Energy Co Ltd F6E315H4A delivers 162.4 W/m2 (3.67 percentage points below 19.91% CEC median) and typical 91.2% PTC-to-STC thermal output (287.3 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft). At -4 F (-20 C), string voltage climbs to 51.92 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with GCL System Integration Technology Co Ltd GCL-P6/72315 (315.0 W).

Where Does United Renewable Energy Co Ltd F6E315H4A Fall Across Listed CEC Models?

Comparison of United Renewable Energy Co Ltd F6E315H4A (315.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd F6E315H4A (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 315.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd F6E315H4A?

Relative ranking of United Renewable Energy Co Ltd F6E315H4A across nameplate watts, 91.2% PTC thermal ratio, and module aperture efficiency.

United Renewable Energy Co Ltd F6E315H4A Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd F6E315H4A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention91.2%Module Efficiency16.24%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F6E315H4A?

Summary of United Renewable Energy Co Ltd F6E315H4A output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,744

16.24% Aperture Efficiency

Power density 162.4 W/m2 (3.67 percentage points below 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.47 V at -10 C (555.2 V string) and 51.92 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,470 W PTC; NEC 690.8 OCPD floor is 14.12 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.4 * (1 + (-0.319/100) * (-10 - 25)) = 50.47 V | OCPD = 1.56 * 9.05 = 14.12 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F6E315H4A: Voc=45.4 V, beta_Voc=-0.319%/C, Isc=9.05 A, STC=315.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (555.2 V); 26 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd F6E315H4A?

Complete CEC test sheet for United Renewable Energy Co Ltd F6E315H4A including Isc (9.05 A), Voc (45.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd F6E315H4A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 287.3 W (91.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.05 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.8 V / 8.34 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.319 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.24% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many United Renewable Energy Co Ltd F6E315H4A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using United Renewable Energy Co Ltd F6E315H4A.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 418 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 543 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 668 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

Related United Renewable Energy Co Ltd power steps and black/silver trims consolidated into this United Renewable Energy Co Ltd F6E315H4A series guide.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd F6E315H4A wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
United Renewable Energy Co Ltd F6E310H4A 310.0 W 282.6 W 45.2 V 37.4 V 15.98%
United Renewable Energy Co Ltd F6E315H4A 315.0 W 287.3 W 45.4 V 37.8 V 16.24%
United Renewable Energy Co Ltd F6E320H4A 320.0 W 292.0 W 45.6 V 38.2 V 16.49%

How Many United Renewable Energy Co Ltd F6E315H4A Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for United Renewable Energy Co Ltd F6E315H4A (45.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.4V and beta_Voc=-0.319%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.92 V 11 panels 571.1 V 19 panels
-10 C (14 F) 50.47 V 11 panels 555.2 V 19 panels
0 C (32 F) 49.02 V 12 panels 588.2 V 20 panels
25 C (77 F STC) 45.4 V 13 panels 590.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F6E315H4A?

Four comparable CEC modules such as GCL System Integration Technology Co Ltd GCL-P6/72315 (315.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/72315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 45.6 V 16.23% 90.5%
CSI Solar Co Ltd CS6U-315P
CSI Solar Co Ltd
315.0 W Tie (0 W) 45.1 V 18.1% 92.3%
Centrosolar America EP72 315BW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
Centrosolar America EP72 315SW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F6E315H4A?

Evaluate United Renewable Energy Co Ltd F6E315H4A (315.0 W STC, 45.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F6E315H4A reaches 51.92 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F6E315H4A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd F6E315H4A 8 kW Residential Fit

Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72315.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 287.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd F6E315H4A by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many United Renewable Energy Co Ltd F6E315H4A panels fit on a 600 V winter solar string?

At -10 C (14 F), United Renewable Energy Co Ltd F6E315H4A cold Voc rises from 45.4 V to 50.47 V (beta_Voc -0.319%/C), capping a 600 V string at 11 panels (555.2 V).

How much roof area does an 8 kW array of United Renewable Energy Co Ltd F6E315H4A need?

An 8 kW DC system uses 26 United Renewable Energy Co Ltd F6E315H4A modules (8,190 W STC / 7,470 W PTC), covering roughly 543 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does United Renewable Energy Co Ltd F6E315H4A compare against GCL System Integration Technology Co Ltd GCL-P6/72315?

United Renewable Energy Co Ltd F6E315H4A outputs 315.0 W STC (45.4 V Voc, rank #15,387 of 21,677), while GCL System Integration Technology Co Ltd GCL-P6/72315 delivers 315.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.