Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd F2M395H8G-BW is a 395.0 W STC (365.7 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 19.85% efficiency, 48.7 V Voc at 25 C, and 53.1 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
365.7 W
Voc @ 25C
48.7 V
Efficiency
19.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd F2M395H8G-BW Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for United Renewable Energy Co Ltd F2M395H8G-BW (Mono-c-Si) residential solar systems.

Homeowners evaluating United Renewable Energy Co Ltd F2M395H8G-BW need 16 panels for 6 kW or 21 panels (450 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (450 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.258%/C) pushes open-circuit voltage to 53.1 V at 14 F and 54.35 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does United Renewable Energy Co Ltd F2M395H8G-BW Fall Across Listed CEC Models?

Comparison of United Renewable Energy Co Ltd F2M395H8G-BW (395.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd F2M395H8G-BW (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 395.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd F2M395H8G-BW?

Relative ranking of United Renewable Energy Co Ltd F2M395H8G-BW across nameplate watts, 92.6% PTC thermal ratio, and module aperture efficiency.

United Renewable Energy Co Ltd F2M395H8G-BW Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd F2M395H8G-BW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention92.6%Module Efficiency19.85%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F2M395H8G-BW?

Summary of United Renewable Energy Co Ltd F2M395H8G-BW output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,028

19.85% Aperture Efficiency

Power density 198.5 W/m2 (0.06 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.1 V at -10 C (584.1 V string) and 54.35 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 41.8 m2 (450 sq ft) producing 7,680 W PTC; NEC 690.8 OCPD floor is 16.08 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.258/100) * (-10 - 25)) = 53.1 V | OCPD = 1.56 * 10.31 = 16.08 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F2M395H8G-BW: Voc=48.7 V, beta_Voc=-0.258%/C, Isc=10.31 A, STC=395.0 W, Area=1.99 m2.

Result: 11 panels max on 600 V (584.1 V); 21 panels for 8 kW (450 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd F2M395H8G-BW?

Complete CEC test sheet for United Renewable Energy Co Ltd F2M395H8G-BW including Isc (10.31 A), Voc (48.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd F2M395H8G-BW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 365.7 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.5 V / 9.76 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.258 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.85% (1.99 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many United Renewable Energy Co Ltd F2M395H8G-BW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using United Renewable Energy Co Ltd F2M395H8G-BW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 343 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 450 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 557 sq ft $2,570 $4,347

How Many United Renewable Energy Co Ltd F2M395H8G-BW Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for United Renewable Energy Co Ltd F2M395H8G-BW (48.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.7V and beta_Voc=-0.258%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.35 V 11 panels 597.9 V 18 panels
-10 C (14 F) 53.1 V 11 panels 584.1 V 18 panels
0 C (32 F) 51.84 V 11 panels 570.2 V 19 panels
25 C (77 F STC) 48.7 V 12 panels 584.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F2M395H8G-BW?

Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W (395.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.26% 92.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.68% 92.5%
Dehui Solar Power (Vietnam) CoLtd DH-M872F 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W Tie (0 W) 48.7 V 20.26% 92.9%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W Tie (0 W) 48.7 V 20.68% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F2M395H8G-BW?

Evaluate United Renewable Energy Co Ltd F2M395H8G-BW (395.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F2M395H8G-BW reaches 54.35 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 450 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (450 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F2M395H8G-BW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd F2M395H8G-BW 8 kW Residential Fit

Needs 21 modules (450 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd F2M395H8G-BW by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is United Renewable Energy Co Ltd F2M395H8G-BW PTC wattage (365.7 W) lower than STC (395.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 365.7 W PTC (92.6% retention) across United Renewable Energy Co Ltd F2M395H8G-BW's 1.99 m2 aperture.

Who should skip United Renewable Energy Co Ltd F2M395H8G-BW on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 United Renewable Energy Co Ltd F2M395H8G-BW panels (450 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd F2M395H8G-BW?

On 1,000 V commercial inverters at -10 C (53.1 V cold Voc), United Renewable Energy Co Ltd F2M395H8G-BW fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.