United Renewable Energy Co Ltd F2K395H8G is a 395.0 W STC (365.9 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 19.85% efficiency, 48.7 V Voc at 25 C, and 53.11 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 365.9 W
- Voc @ 25C
- 48.7 V
- Efficiency
- 19.85%
How Does United Renewable Energy Co Ltd F2K395H8G Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for United Renewable Energy Co Ltd F2K395H8G (Mono-c-Si) residential solar systems.
Homeowners evaluating United Renewable Energy Co Ltd F2K395H8G need 16 panels for 6 kW or 21 panels (450 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (450 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.259%/C) pushes open-circuit voltage to 53.11 V at 14 F and 54.38 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does United Renewable Energy Co Ltd F2K395H8G Fall Across Listed CEC Models?
Comparison of United Renewable Energy Co Ltd F2K395H8G (395.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define United Renewable Energy Co Ltd F2K395H8G?
Relative ranking of United Renewable Energy Co Ltd F2K395H8G across nameplate watts, 92.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F2K395H8G?
Summary of United Renewable Energy Co Ltd F2K395H8G output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.85% Aperture Efficiency
Power density 198.5 W/m2 (0.06 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.11 V at -10 C (584.2 V string) and 54.38 V at -20 C (11 max).
21 Panels = 8,295 W STC
Occupies 41.8 m2 (450 sq ft) producing 7,684 W PTC; NEC 690.8 OCPD floor is 16.08 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.7 * (1 + (-0.259/100) * (-10 - 25)) = 53.11 V | OCPD = 1.56 * 10.31 = 16.08 A
Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F2K395H8G: Voc=48.7 V, beta_Voc=-0.259%/C, Isc=10.31 A, STC=395.0 W, Area=1.99 m2.
Result: 11 panels max on 600 V (584.2 V); 21 panels for 8 kW (450 sq ft).
What Are the Published CEC Specifications for United Renewable Energy Co Ltd F2K395H8G?
Complete CEC test sheet for United Renewable Energy Co Ltd F2K395H8G including Isc (10.31 A), Voc (48.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 365.9 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.31 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.5 V / 9.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.259 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.85% (1.99 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many United Renewable Energy Co Ltd F2K395H8G Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using United Renewable Energy Co Ltd F2K395H8G.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 343 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 450 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 557 sq ft | $2,570 | $4,347 |
How Many United Renewable Energy Co Ltd F2K395H8G Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for United Renewable Energy Co Ltd F2K395H8G (48.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.38 V | 11 panels | 598.2 V | 18 panels |
| -10 C (14 F) | 53.11 V | 11 panels | 584.2 V | 18 panels |
| 0 C (32 F) | 51.85 V | 11 panels | 570.4 V | 19 panels |
| 25 C (77 F STC) | 48.7 V | 12 panels | 584.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F2K395H8G?
Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W (395.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | Tie (0 W) | 48.7 V | 20.68% | 92.5% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872F 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 48.7 V | 20.68% | 92.5% |
What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F2K395H8G?
Evaluate United Renewable Energy Co Ltd F2K395H8G (395.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F2K395H8G reaches 54.38 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 450 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (450 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F2K395H8G carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
United Renewable Energy Co Ltd F2K395H8G 8 kW Residential Fit
Needs 21 modules (450 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for United Renewable Energy Co Ltd F2K395H8G by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is United Renewable Energy Co Ltd F2K395H8G PTC wattage (365.9 W) lower than STC (395.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 365.9 W PTC (92.6% retention) across United Renewable Energy Co Ltd F2K395H8G's 1.99 m2 aperture.
Who should skip United Renewable Energy Co Ltd F2K395H8G on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 United Renewable Energy Co Ltd F2K395H8G panels (450 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.
What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd F2K395H8G?
On 1,000 V commercial inverters at -10 C (53.11 V cold Voc), United Renewable Energy Co Ltd F2K395H8G fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)