United Renewable Energy Co Ltd D6M285B3AME is a 285.0 W STC (254.1 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 17.52% efficiency, 39.12 V Voc at 25 C, and 43.91 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 254.1 W
- Voc @ 25C
- 39.12 V
- Efficiency
- 17.52%
How Does United Renewable Energy Co Ltd D6M285B3AME Compare Against Peer CEC Listings?
How United Renewable Energy Co Ltd United Renewable Energy Co Ltd D6M285B3AME handles rooftop heat (254.1 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, United Renewable Energy Co Ltd D6M285B3AME exhibits 9.62 A short-circuit current, requiring a 15.01 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #17,598 of 21,677 (125.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 47.2 m2 for an 8 kW system (36 panels for 10 kW). Lower 39.12 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does United Renewable Energy Co Ltd D6M285B3AME Fall Across Listed CEC Models?
Where United Renewable Energy Co Ltd D6M285B3AME (285.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define United Renewable Energy Co Ltd D6M285B3AME?
Percentile placement of United Renewable Energy Co Ltd D6M285B3AME across power density (175.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for United Renewable Energy Co Ltd D6M285B3AME?
Four critical engineering numbers homeowners and solar installers check first when reviewing United Renewable Energy Co Ltd D6M285B3AME specifications.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.52% Aperture Efficiency
Power density 175.2 W/m2 (2.39 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.91 V at -10 C (570.8 V string) and 45.28 V at -20 C (13 max).
29 Panels = 8,265 W STC
Occupies 47.2 m2 (508 sq ft) producing 7,369 W PTC; NEC 690.8 OCPD floor is 15.01 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.12 * (1 + (-0.35/100) * (-10 - 25)) = 43.91 V | OCPD = 1.56 * 9.62 = 15.01 A
Inputs from CEC Modules.csv for United Renewable Energy Co Ltd D6M285B3AME: Voc=39.12 V, beta_Voc=-0.35%/C, Isc=9.62 A, STC=285.0 W, Area=1.627 m2.
Result: 13 panels max on 600 V (570.8 V); 29 panels for 8 kW (508 sq ft).
What Are the Published CEC Specifications for United Renewable Energy Co Ltd D6M285B3AME?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for United Renewable Energy Co Ltd D6M285B3AME.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 254.1 W (89.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.12 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.5 V / 9.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.35 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.52% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many United Renewable Energy Co Ltd D6M285B3AME Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using United Renewable Energy Co Ltd D6M285B3AME (285.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 385 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 508 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 630 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?
All closely matched United Renewable Energy Co Ltd wattages and cosmetic trims sharing the United Renewable Energy Co Ltd D6M285B3AME architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| United Renewable Energy Co Ltd D6M275B3AME | 275.0 W | 248.4 W | 38.99 V | 31.27 V | 16.9% |
| United Renewable Energy Co Ltd D6M280B3AME | 280.0 W | 253.1 W | 39.04 V | 31.33 V | 17.21% |
| United Renewable Energy Co Ltd D6M285B3AME | 285.0 W | 254.1 W | 39.12 V | 31.5 V | 17.52% |
| United Renewable Energy Co Ltd D6M290B3AME | 290.0 W | 258.7 W | 39.18 V | 31.61 V | 17.83% |
| United Renewable Energy Co Ltd D6M295B3AME | 295.0 W | 263.4 W | 39.27 V | 31.86 V | 18.13% |
How Many United Renewable Energy Co Ltd D6M285B3AME Modules Fit in a Cold-Weather String?
Maximum series module counts for United Renewable Energy Co Ltd D6M285B3AME from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.28 V | 13 panels | 588.6 V | 22 panels |
| -10 C (14 F) | 43.91 V | 13 panels | 570.8 V | 22 panels |
| 0 C (32 F) | 42.54 V | 14 panels | 595.6 V | 23 panels |
| 25 C (77 F STC) | 39.12 V | 15 panels | 586.8 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd D6M285B3AME?
Alternative CEC solar modules from competing brands near United Renewable Energy Co Ltd D6M285B3AME (285.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-285W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-285W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
285.0 W | Tie (0 W) | 39.18 V | 17.69% | 91.4% |
| Centrosolar America EM60 285BW Centrosolar America |
285.0 W | Tie (0 W) | 39.18 V | 17.69% | 91.4% |
| Centrosolar America EM60 285SW Centrosolar America |
285.0 W | Tie (0 W) | 39.18 V | 17.69% | 91.4% |
| Boviet Solar Technology Co Ltd BVM6610P-285 Boviet Solar Technology Co Ltd |
285.0 W | Tie (0 W) | 39.0 V | 17.52% | 92.5% |
What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd D6M285B3AME?
Evaluate United Renewable Energy Co Ltd D6M285B3AME (285.0 W STC, 39.12 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd D6M285B3AME reaches 45.28 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 508 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (508 sq ft).
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd D6M285B3AME carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
United Renewable Energy Co Ltd D6M285B3AME 8 kW Residential Fit
Needs 29 modules (508 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-285W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 254.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for United Renewable Energy Co Ltd D6M285B3AME by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is United Renewable Energy Co Ltd D6M285B3AME PTC wattage (254.1 W) lower than STC (285.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 254.1 W PTC (89.2% retention) across United Renewable Energy Co Ltd D6M285B3AME's 1.627 m2 aperture.
Who should skip United Renewable Energy Co Ltd D6M285B3AME on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 United Renewable Energy Co Ltd D6M285B3AME panels (508 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-285W.
What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd D6M285B3AME?
On 1,000 V commercial inverters at -10 C (43.91 V cold Voc), United Renewable Energy Co Ltd D6M285B3AME fits up to 22 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)