United Renewable Energy Co Ltd D6L345L4A is a 345.0 W STC (319.5 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.34% efficiency, 46.96 V Voc at 25 C, and 52.1 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 345.0 W
- PTC Wattage
- 319.5 W
- Voc @ 25C
- 46.96 V
- Efficiency
- 17.34%
How Does United Renewable Energy Co Ltd D6L345L4A Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for United Renewable Energy Co Ltd D6L345L4A (Mono-c-Si) residential solar systems.
Homeowners evaluating United Renewable Energy Co Ltd D6L345L4A need 18 panels for 6 kW or 24 panels (514 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (514 sq ft). Under NEC 690.7(A), beta_Voc (-0.313%/C) pushes open-circuit voltage to 52.1 V at 14 F and 53.57 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does United Renewable Energy Co Ltd D6L345L4A Fall Across Listed CEC Models?
Comparison of United Renewable Energy Co Ltd D6L345L4A (345.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define United Renewable Energy Co Ltd D6L345L4A?
Relative ranking of United Renewable Energy Co Ltd D6L345L4A across nameplate watts, 92.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for United Renewable Energy Co Ltd D6L345L4A?
Summary of United Renewable Energy Co Ltd D6L345L4A output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.
345.0 W STC · Higher Than 37.4%
345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.34% Aperture Efficiency
Power density 173.4 W/m2 (2.57 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.1 V at -10 C (573.1 V string) and 53.57 V at -20 C (11 max).
24 Panels = 8,280 W STC
Occupies 47.8 m2 (514 sq ft) producing 7,668 W PTC; NEC 690.8 OCPD floor is 15.13 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.96 * (1 + (-0.313/100) * (-10 - 25)) = 52.1 V | OCPD = 1.56 * 9.7 = 15.13 A
Inputs from CEC Modules.csv for United Renewable Energy Co Ltd D6L345L4A: Voc=46.96 V, beta_Voc=-0.313%/C, Isc=9.7 A, STC=345.0 W, Area=1.99 m2.
Result: 11 panels max on 600 V (573.1 V); 24 panels for 8 kW (514 sq ft).
What Are the Published CEC Specifications for United Renewable Energy Co Ltd D6L345L4A?
Complete CEC test sheet for United Renewable Energy Co Ltd D6L345L4A including Isc (9.7 A), Voc (46.96 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 319.5 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.96 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.97 V / 9.08 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.313 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.34% (1.99 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many United Renewable Energy Co Ltd D6L345L4A Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using United Renewable Energy Co Ltd D6L345L4A.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.21 kW | 386 sq ft | $1,554 | $2,628 |
| 8 kW Class | 24 | 8.28 kW | 514 sq ft | $2,072 | $3,504 |
| 10 kW Class | 29 | 10.01 kW | 621 sq ft | $2,505 | $4,236 |
How Many United Renewable Energy Co Ltd D6L345L4A Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for United Renewable Energy Co Ltd D6L345L4A (46.96 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.57 V | 11 panels | 589.3 V | 18 panels |
| -10 C (14 F) | 52.1 V | 11 panels | 573.1 V | 19 panels |
| 0 C (32 F) | 50.63 V | 11 panels | 556.9 V | 19 panels |
| 25 C (77 F STC) | 46.96 V | 12 panels | 563.5 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd D6L345L4A?
Four comparable CEC modules such as Auxin Solar AXN6M612B345 (345.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M612B345 Auxin Solar |
345.0 W | Tie (0 W) | 47.28 V | 17.52% | 92.9% |
| CSI Solar Co Ltd CS3U-345PB-AG CSI Solar Co Ltd |
345.0 W | Tie (0 W) | 46.4 V | 17.78% | 92.4% |
| AXITEC AC-345M/156-72S AXITEC |
345.0 W | Tie (0 W) | 47.0 V | 17.78% | 91.4% |
| GCL System Integration Technology Co Ltd GCL-P3/72H345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.88 V | 17.16% | 93.1% |
What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd D6L345L4A?
Evaluate United Renewable Energy Co Ltd D6L345L4A (345.0 W STC, 46.96 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd D6L345L4A reaches 53.57 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 514 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (514 sq ft).
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd D6L345L4A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
United Renewable Energy Co Ltd D6L345L4A 8 kW Residential Fit
Needs 24 modules (514 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612B345.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 319.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for United Renewable Energy Co Ltd D6L345L4A by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is United Renewable Energy Co Ltd D6L345L4A PTC wattage (319.5 W) lower than STC (345.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 319.5 W PTC (92.6% retention) across United Renewable Energy Co Ltd D6L345L4A's 1.99 m2 aperture.
Who should skip United Renewable Energy Co Ltd D6L345L4A on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 United Renewable Energy Co Ltd D6L345L4A panels (514 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M612B345.
What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd D6L345L4A?
On 1,000 V commercial inverters at -10 C (52.1 V cold Voc), United Renewable Energy Co Ltd D6L345L4A fits up to 19 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)