Trina Solar TSM-550DE19 is a 550.0 W STC (510.1 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.24% efficiency, 37.9 V Voc at 25 C, and 41.42 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 550.0 W
- PTC Wattage
- 510.1 W
- Voc @ 25C
- 37.9 V
- Efficiency
- 21.24%
How Does Trina Solar TSM-550DE19 Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-550DE19: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Across 5,889 Mono-c-Si listings from Trina Solar and peers, Trina Solar TSM-550DE19 stands 140.0 W above the 410.0 W Mono-c-Si median and strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677). Sizing 6 kW (11 panels) to 10 kW (19 panels) yields $1,514-$2,616/yr in baseline US bill offset. Lower 37.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Trina Solar TSM-550DE19 Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-550DE19 (550.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define Trina Solar TSM-550DE19?
Dataset percentiles tracking Trina Solar TSM-550DE19 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for Trina Solar TSM-550DE19?
Benchmark highlights for Trina Solar TSM-550DE19 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Top 13.8% STC Output
550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.24% Aperture Efficiency
Power density 212.4 W/m2 (1.33 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.42 V at -10 C (579.9 V string) and 42.42 V at -20 C (14 max).
15 Panels = 8,250 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,652 W PTC; NEC 690.8 OCPD floor is 28.89 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.9 * (1 + (-0.265/100) * (-10 - 25)) = 41.42 V | OCPD = 1.56 * 18.52 = 28.89 A
Inputs from CEC Modules.csv for Trina Solar TSM-550DE19: Voc=37.9 V, beta_Voc=-0.265%/C, Isc=18.52 A, STC=550.0 W, Area=2.59 m2.
Result: 14 panels max on 600 V (579.9 V); 15 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-550DE19?
Official CEC datasheet figures for Trina Solar TSM-550DE19 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 510.1 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.52 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.6 V / 17.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.265 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.24% (2.59 m2) | Array roof footprint density |
| Cell Count & Technology | 55 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-550DE19 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-550DE19 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.05 kW | 307 sq ft | $1,514 | $2,561 |
| 8 kW Class | 15 | 8.25 kW | 418 sq ft | $2,065 | $3,492 |
| 10 kW Class | 19 | 10.45 kW | 530 sq ft | $2,616 | $4,423 |
How Many Trina Solar TSM-550DE19 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-550DE19 (41.42 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.42 V | 14 panels | 593.9 V | 23 panels |
| -10 C (14 F) | 41.42 V | 14 panels | 579.9 V | 24 panels |
| 0 C (32 F) | 40.41 V | 14 panels | 565.7 V | 24 panels |
| 25 C (77 F STC) | 37.9 V | 15 panels | 568.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-550DE19?
Competing CEC solar panels closest to Trina Solar TSM-550DE19 in nameplate wattage and Voc, starting with CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
550.0 W | Tie (0 W) | 37.9 V | 21.48% | 93.7% |
| CSI Solar Co Ltd CS7L-585MS-R CSI Solar Co Ltd |
585.0 W | +35.0 W | 40.7 V | 20.89% | 94.0% |
| Energate Energy Inc EG-144L550W Energate Energy Inc |
550.0 W | Tie (0 W) | 49.62 V | 21.48% | 93.8% |
| Energate Enerji retim San A EG-144L550W Energate Enerji retim San A |
550.0 W | Tie (0 W) | 49.62 V | 21.48% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-550DE19?
Evaluate Trina Solar TSM-550DE19 (550.0 W STC, 37.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-550DE19 reaches 42.42 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 418 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-550DE19 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-550DE19 8 kW Residential Fit
Needs 15 modules (418 sq ft) with a 30 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 510.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-550DE19 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-550DE19?
Multiplying Trina Solar TSM-550DE19's 18.52 A short-circuit current by 1.56 equals 28.89 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can Trina Solar TSM-550DE19 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.42 V cold Voc at 14 F and handles 18.52 A Isc; string inverters cap Trina Solar TSM-550DE19 at 14 panels on 600 V.
Is Trina Solar TSM-550DE19 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-550DE19 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)