Trina Solar TSM-470DEG15VC20(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-470DEG15VC20(II) is a 470.0 W STC (442.1 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 20.17% efficiency, 43.1 V Voc at 25 C, and 46.58 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
470.0 W
PTC Wattage
442.1 W
Voc @ 25C
43.1 V
Efficiency
20.17%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-470DEG15VC20(II) Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-470DEG15VC20(II) handles rooftop heat (442.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Trina Solar TSM-470DEG15VC20(II) exhibits 13.68 A short-circuit current, requiring a 21.34 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #4,967 of 21,677 (60.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 41.9 m2 for an 8 kW system (22 panels for 10 kW). Mid-range 43.1 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Trina Solar TSM-470DEG15VC20(II) Fall Across Listed CEC Models?

Where Trina Solar TSM-470DEG15VC20(II) (470.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-470DEG15VC20(II) (470.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-47: 470.0 W

What Dataset Percentiles Define Trina Solar TSM-470DEG15VC20(II)?

Percentile placement of Trina Solar TSM-470DEG15VC20(II) across power density (201.7 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-470DEG15VC20(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-470DEG15VC20(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage470.0 WPTC/STC Retention94.1%Module Efficiency20.17%

What Do the Dataset Ranks Show for Trina Solar TSM-470DEG15VC20(II)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-470DEG15VC20(II) specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #4,967 / 21,677

Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,881

20.17% Aperture Efficiency

Power density 201.7 W/m2 (0.26 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.58 V at -10 C (559.0 V string) and 47.58 V at -20 C (12 max).

8 kW Reference Array

18 Panels = 8,460 W STC

Occupies 41.9 m2 (451 sq ft) producing 7,958 W PTC; NEC 690.8 OCPD floor is 21.34 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.1 * (1 + (-0.231/100) * (-10 - 25)) = 46.58 V | OCPD = 1.56 * 13.68 = 21.34 A

Inputs from CEC Modules.csv for Trina Solar TSM-470DEG15VC20(II): Voc=43.1 V, beta_Voc=-0.231%/C, Isc=13.68 A, STC=470.0 W, Area=2.33 m2.

Result: 12 panels max on 600 V (559.0 V); 18 panels for 8 kW (451 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-470DEG15VC20(II)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-470DEG15VC20(II).

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-470DEG15VC20(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 470.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 442.1 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.68 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.9 V / 13.09 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.231 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.17% (2.33 m2) Array roof footprint density
Cell Count & Technology 126 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-470DEG15VC20(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-470DEG15VC20(II) (470.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.11 kW 326 sq ft $1,529 $2,586
8 kW Class 18 8.46 kW 451 sq ft $2,117 $3,580
10 kW Class 22 10.34 kW 552 sq ft $2,588 $4,376

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-470DEG15VC20(II) architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Trina Solar TSM-470DEG15VC20(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-465DEG15VC20(II) 465.0 W 437.3 W 43.0 V 35.8 V 19.96%
Trina Solar TSM-470DEG15VC20(II) 470.0 W 442.1 W 43.1 V 35.9 V 20.17%

How Many Trina Solar TSM-470DEG15VC20(II) Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-470DEG15VC20(II) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.1V and beta_Voc=-0.231%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.58 V 12 panels 571.0 V 21 panels
-10 C (14 F) 46.58 V 12 panels 559.0 V 21 panels
0 C (32 F) 45.59 V 13 panels 592.7 V 21 panels
25 C (77 F STC) 43.1 V 13 panels 560.3 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-470DEG15VC20(II)?

Alternative CEC solar modules from competing brands near Trina Solar TSM-470DEG15VC20(II) (470.0 W), including Auxin Solar AXN10M470W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN10M470W
Auxin Solar
470.0 W Tie (0 W) 43.78 V 21.86% 92.0%
Aptos Solar Technology LLC DNA-120-BFN10-470W-DG
Aptos Solar Technology LLC
470.0 W Tie (0 W) 42.38 V 21.76% 94.9%
CSI Solar Co Ltd CS61-60TM-470H
CSI Solar Co Ltd
470.0 W Tie (0 W) 42.0 V 21.46% 94.6%
Auxin Solar AXN10M465B
Auxin Solar
465.0 W -5.0 W 43.72 V 21.63% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-470DEG15VC20(II)?

Evaluate Trina Solar TSM-470DEG15VC20(II) (470.0 W STC, 43.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-470DEG15VC20(II) reaches 47.58 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 451 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (451 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-470DEG15VC20(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-470DEG15VC20(II) 8 kW Residential Fit

Needs 18 modules (451 sq ft) with a 25 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN10M470W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 442.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-470DEG15VC20(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-470DEG15VC20(II) PTC wattage (442.1 W) lower than STC (470.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 442.1 W PTC (94.1% retention) across Trina Solar TSM-470DEG15VC20(II)'s 2.33 m2 aperture.

Who should skip Trina Solar TSM-470DEG15VC20(II) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Trina Solar TSM-470DEG15VC20(II) panels (451 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M470W.

What is the 1,000 V commercial string limit for Trina Solar TSM-470DEG15VC20(II)?

On 1,000 V commercial inverters at -10 C (46.58 V cold Voc), Trina Solar TSM-470DEG15VC20(II) fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-470DEG15VC20(II).

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.