Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-395DEG15M(II) is a 395.0 W STC (372.6 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 19.65% efficiency, 48.7 V Voc at 25 C, and 53.13 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
372.6 W
Voc @ 25C
48.7 V
Efficiency
19.65%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-395DEG15M(II) Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-395DEG15M(II) handles rooftop heat (372.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Trina Solar TSM-395DEG15M(II) exhibits 10.37 A short-circuit current, requiring a 16.18 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 42.2 m2 for an 8 kW system (26 panels for 10 kW). Higher 48.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Trina Solar TSM-395DEG15M(II) Fall Across Listed CEC Models?

Where Trina Solar TSM-395DEG15M(II) (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-395DEG15M(II) (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-39: 395.0 W

What Dataset Percentiles Define Trina Solar TSM-395DEG15M(II)?

Percentile placement of Trina Solar TSM-395DEG15M(II) across power density (196.5 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-395DEG15M(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-395DEG15M(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention94.3%Module Efficiency19.65%

What Do the Dataset Ranks Show for Trina Solar TSM-395DEG15M(II)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-395DEG15M(II) specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,653

19.65% Aperture Efficiency

Power density 196.5 W/m2 (0.26 percentage points below 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.13 V at -10 C (584.4 V string) and 54.4 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 42.2 m2 (454 sq ft) producing 7,825 W PTC; NEC 690.8 OCPD floor is 16.18 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.26/100) * (-10 - 25)) = 53.13 V | OCPD = 1.56 * 10.37 = 16.18 A

Inputs from CEC Modules.csv for Trina Solar TSM-395DEG15M(II): Voc=48.7 V, beta_Voc=-0.26%/C, Isc=10.37 A, STC=395.0 W, Area=2.01 m2.

Result: 11 panels max on 600 V (584.4 V); 21 panels for 8 kW (454 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-395DEG15M(II)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-395DEG15M(II).

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-395DEG15M(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 372.6 W (94.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.37 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.1 V / 9.86 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.26 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.65% (2.01 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-395DEG15M(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-395DEG15M(II) (395.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 346 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 454 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 563 sq ft $2,570 $4,347

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-395DEG15M(II) architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Trina Solar TSM-395DEG15M(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-390DEG15M(II) 390.0 W 367.8 W 48.5 V 40.0 V 19.4%
Trina Solar TSM-395DEG15M(II) 395.0 W 372.6 W 48.7 V 40.1 V 19.65%

How Many Trina Solar TSM-395DEG15M(II) Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-395DEG15M(II) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.7V and beta_Voc=-0.26%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.4 V 11 panels 598.4 V 18 panels
-10 C (14 F) 53.13 V 11 panels 584.4 V 18 panels
0 C (32 F) 51.87 V 11 panels 570.6 V 19 panels
25 C (77 F STC) 48.7 V 12 panels 584.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-395DEG15M(II)?

Alternative CEC solar modules from competing brands near Trina Solar TSM-395DEG15M(II) (395.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.26% 92.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.68% 92.5%
Dehui Solar Power (Vietnam) CoLtd DH-M872F 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W Tie (0 W) 48.7 V 20.26% 92.9%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W Tie (0 W) 48.7 V 20.68% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-395DEG15M(II)?

Evaluate Trina Solar TSM-395DEG15M(II) (395.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-395DEG15M(II) reaches 54.4 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 454 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (454 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-395DEG15M(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-395DEG15M(II) 8 kW Residential Fit

Needs 21 modules (454 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 372.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-395DEG15M(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-395DEG15M(II) PTC wattage (372.6 W) lower than STC (395.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 372.6 W PTC (94.3% retention) across Trina Solar TSM-395DEG15M(II)'s 2.01 m2 aperture.

Who should skip Trina Solar TSM-395DEG15M(II) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Trina Solar TSM-395DEG15M(II) panels (454 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

What is the 1,000 V commercial string limit for Trina Solar TSM-395DEG15M(II)?

On 1,000 V commercial inverters at -10 C (53.13 V cold Voc), Trina Solar TSM-395DEG15M(II) fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-395DEG15M(II).

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.