Trina Solar TSM-390DE15H(II) is a 390.0 W STC (365.4 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 19.64% efficiency, 49.7 V Voc at 25 C, and 54.4 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 365.4 W
- Voc @ 25C
- 49.7 V
- Efficiency
- 19.64%
How Does Trina Solar TSM-390DE15H(II) Compare Against Peer CEC Listings?
Engineering position of Trina Solar TSM-390DE15H(II) (390.0 W STC) vs. ELITE Solar ET-M672BH395GL across 5,889 CEC Mono-c-Si solar modules.
Built with 48 Mono-c-Si cells, Trina Solar TSM-390DE15H(II) pairs strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677) with 49.7 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,673 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer ELITE Solar ET-M672BH395GL offers a 395.0 W alternative.
Where Does Trina Solar TSM-390DE15H(II) Fall Across Listed CEC Models?
Plots Trina Solar TSM-390DE15H(II) at 390.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Trina Solar TSM-390DE15H(II)?
Benchmarks Trina Solar TSM-390DE15H(II) on STC wattage, thermal PTC/STC retention, and 19.64 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Trina Solar TSM-390DE15H(II)?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-390DE15H(II) by Trina Solar.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.64% Aperture Efficiency
Power density 196.4 W/m2 (0.27 percentage points below 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.4 V at -10 C (598.4 V string) and 55.74 V at -20 C (10 max).
21 Panels = 8,190 W STC
Occupies 41.7 m2 (449 sq ft) producing 7,673 W PTC; NEC 690.8 OCPD floor is 15.72 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.7 * (1 + (-0.27/100) * (-10 - 25)) = 54.4 V | OCPD = 1.56 * 10.08 = 15.72 A
Inputs from CEC Modules.csv for Trina Solar TSM-390DE15H(II): Voc=49.7 V, beta_Voc=-0.27%/C, Isc=10.08 A, STC=390.0 W, Area=1.986 m2.
Result: 11 panels max on 600 V (598.4 V); 21 panels for 8 kW (449 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-390DE15H(II)?
Laboratory test ratings recorded for Trina Solar TSM-390DE15H(II) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 365.4 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.08 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.5 V / 9.64 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.27 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.64% (1.986 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-390DE15H(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (449 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-390DE15H(II).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 342 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 449 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 556 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Sibling wattage bins and frame colors grouped with Trina Solar TSM-390DE15H(II) under Trina Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-385DE15H(II) | 385.0 W | 360.6 W | 48.5 V | 40.1 V | 19.39% |
| Trina Solar TSM-390DE15H(II) | 390.0 W | 365.4 W | 49.7 V | 40.5 V | 19.64% |
| Trina Solar TSM-395DE15H(II) | 395.0 W | 370.2 W | 50.1 V | 40.8 V | 19.89% |
How Many Trina Solar TSM-390DE15H(II) Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Trina Solar TSM-390DE15H(II) (beta_Voc -0.27%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.74 V | 10 panels | 557.4 V | 17 panels |
| -10 C (14 F) | 54.4 V | 11 panels | 598.4 V | 18 panels |
| 0 C (32 F) | 53.05 V | 11 panels | 583.5 V | 18 panels |
| 25 C (77 F STC) | 49.7 V | 12 panels | 596.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-390DE15H(II)?
Closest cross-brand CEC competitors to Trina Solar TSM-390DE15H(II) matched near 390.0 W STC and 49.7 V Voc, led by ELITE Solar ET-M672BH395GL.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ELITE Solar ET-M672BH395GL ELITE Solar |
395.0 W | +5.0 W | 49.6 V | 19.36% | 93.2% |
| ELITE Solar ET-M672BH395WW ELITE Solar |
395.0 W | +5.0 W | 49.5 V | 19.85% | 93.3% |
| CSI Solar Co Ltd CS3U-390MS CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 48.2 V | 20.31% | 93.2% |
| BYD Company Limited BYD415MIK-36 BYD Company Limited |
395.0 W | +5.0 W | 50.06 V | 19.65% | 93.9% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-390DE15H(II)?
Evaluate Trina Solar TSM-390DE15H(II) (390.0 W STC, 49.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-390DE15H(II) reaches 55.74 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 449 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (449 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-390DE15H(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-390DE15H(II) 8 kW Residential Fit
Needs 21 modules (449 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ELITE Solar ET-M672BH395GL.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-390DE15H(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-390DE15H(II)?
Multiplying Trina Solar TSM-390DE15H(II)'s 10.08 A short-circuit current by 1.56 equals 15.72 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Trina Solar TSM-390DE15H(II) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.4 V cold Voc at 14 F and handles 10.08 A Isc; string inverters cap Trina Solar TSM-390DE15H(II) at 11 panels on 600 V.
Is Trina Solar TSM-390DE15H(II) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-390DE15H(II) rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)