Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-385DE0905 is a 385.0 W STC (362.3 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 20.16% efficiency, 40.6 V Voc at 25 C, and 43.97 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
385.0 W
PTC Wattage
362.3 W
Voc @ 25C
40.6 V
Efficiency
20.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-385DE0905 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-385DE0905 handles rooftop heat (362.3 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-385DE0905 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 201.6 W/m2 (0.25 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS3L-385MS (385.0 W), this model holds strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Mid-range 40.6 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 18.83 A overcurrent floor served by a 20 A breaker.

Where Does Trina Solar TSM-385DE0905 Fall Across Listed CEC Models?

Where Trina Solar TSM-385DE0905 (385.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-385DE0905 (385.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-38: 385.0 W

What Dataset Percentiles Define Trina Solar TSM-385DE0905?

Percentile placement of Trina Solar TSM-385DE0905 across power density (201.6 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-385DE0905 Engineering BenchmarksPercentile comparison of Trina Solar TSM-385DE0905 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage385.0 WPTC/STC Retention94.1%Module Efficiency20.16%

What Do the Dataset Ranks Show for Trina Solar TSM-385DE0905?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-385DE0905 specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #10,723 / 21,677

385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,907

20.16% Aperture Efficiency

Power density 201.6 W/m2 (0.25 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.97 V at -10 C (571.6 V string) and 44.93 V at -20 C (13 max).

8 kW Reference Array

21 Panels = 8,085 W STC

Occupies 40.1 m2 (432 sq ft) producing 7,608 W PTC; NEC 690.8 OCPD floor is 18.83 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.6 * (1 + (-0.237/100) * (-10 - 25)) = 43.97 V | OCPD = 1.56 * 12.07 = 18.83 A

Inputs from CEC Modules.csv for Trina Solar TSM-385DE0905: Voc=40.6 V, beta_Voc=-0.237%/C, Isc=12.07 A, STC=385.0 W, Area=1.91 m2.

Result: 13 panels max on 600 V (571.6 V); 21 panels for 8 kW (432 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-385DE0905?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-385DE0905.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-385DE0905.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 385.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 362.3 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 12.07 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.6 V / 11.46 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.237 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.16% (1.91 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-385DE0905 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-385DE0905 (385.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.16 kW 329 sq ft $1,542 $2,607
8 kW Class 21 8.09 kW 432 sq ft $2,025 $3,424
10 kW Class 26 10.01 kW 535 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-385DE0905 architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the Trina Solar TSM-385DE0905 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-375DE0905 375.0 W 352.7 W 40.2 V 33.2 V 19.63%
Trina Solar TSM-380DE0905 380.0 W 357.5 W 40.4 V 33.4 V 19.9%
Trina Solar TSM-385DE0905 385.0 W 362.3 W 40.6 V 33.6 V 20.16%
Trina Solar TSM-390DE0905 390.0 W 367.1 W 40.8 V 33.8 V 20.42%
Trina Solar TSM-395DE0905 395.0 W 372.0 W 41.0 V 34.0 V 20.68%

How Many Trina Solar TSM-385DE0905 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-385DE0905 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.6V and beta_Voc=-0.237%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.93 V 13 panels 584.1 V 22 panels
-10 C (14 F) 43.97 V 13 panels 571.6 V 22 panels
0 C (32 F) 43.01 V 13 panels 559.1 V 23 panels
25 C (77 F STC) 40.6 V 14 panels 568.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-385DE0905?

Alternative CEC solar modules from competing brands near Trina Solar TSM-385DE0905 (385.0 W), including CSI Solar Co Ltd CS3L-385MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3L-385MS
CSI Solar Co Ltd
385.0 W Tie (0 W) 41.4 V 21.51% 93.2%
Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC
Boviet Solar Technology Co Ltd
380.0 W -5.0 W 40.94 V 20.54% 94.2%
DualSun SAS DualSun 380M-120-01
DualSun SAS
380.0 W -5.0 W 41.3 V 21.47% 93.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W -10.0 W 41.1 V 21.07% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-385DE0905?

Evaluate Trina Solar TSM-385DE0905 (385.0 W STC, 40.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-385DE0905 reaches 44.93 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 432 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (432 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-385DE0905 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-385DE0905 8 kW Residential Fit

Needs 21 modules (432 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-385MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 362.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-385DE0905 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-385DE0905?

Multiplying Trina Solar TSM-385DE0905's 12.07 A short-circuit current by 1.56 equals 18.83 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Trina Solar TSM-385DE0905 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.97 V cold Voc at 14 F and handles 12.07 A Isc; string inverters cap Trina Solar TSM-385DE0905 at 13 panels on 600 V.

Is Trina Solar TSM-385DE0905 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-385DE0905 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.