Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-345DEG1440(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-345DEG1440(II) is a 345.0 W STC (313.7 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.58% efficiency, 46.7 V Voc at 25 C, and 51.62 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
345.0 W
PTC Wattage
313.7 W
Voc @ 25C
46.7 V
Efficiency
17.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-345DEG1440(II) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-345DEG1440(II) (Mono-c-Si) residential solar systems.

Trina Solar TSM-345DEG1440(II) delivers 175.8 W/m2 (2.33 percentage points below 19.91% CEC median) and typical 90.9% PTC-to-STC thermal output (313.7 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (507 sq ft). At -4 F (-20 C), string voltage climbs to 53.03 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with GCL System Integration Technology Co Ltd GCL-M6/72345 (345.0 W).

Where Does Trina Solar TSM-345DEG1440(II) Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-345DEG1440(II) (345.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-345DEG1440(II) (345.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-34: 345.0 W

What Dataset Percentiles Define Trina Solar TSM-345DEG1440(II)?

Relative ranking of Trina Solar TSM-345DEG1440(II) across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency.

Trina Solar TSM-345DEG1440(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-345DEG1440(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage345.0 WPTC/STC Retention90.9%Module Efficiency17.58%

What Do the Dataset Ranks Show for Trina Solar TSM-345DEG1440(II)?

Summary of Trina Solar TSM-345DEG1440(II) output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.

Rank #13,309 / 21,677

345.0 W STC · Higher Than 37.4%

345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,678

17.58% Aperture Efficiency

Power density 175.8 W/m2 (2.33 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.62 V at -10 C (567.8 V string) and 53.03 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,280 W STC

Occupies 47.1 m2 (507 sq ft) producing 7,529 W PTC; NEC 690.8 OCPD floor is 14.82 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.7 * (1 + (-0.301/100) * (-10 - 25)) = 51.62 V | OCPD = 1.56 * 9.5 = 14.82 A

Inputs from CEC Modules.csv for Trina Solar TSM-345DEG1440(II): Voc=46.7 V, beta_Voc=-0.301%/C, Isc=9.5 A, STC=345.0 W, Area=1.962 m2.

Result: 11 panels max on 600 V (567.8 V); 24 panels for 8 kW (507 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-345DEG1440(II)?

Complete CEC test sheet for Trina Solar TSM-345DEG1440(II) including Isc (9.5 A), Voc (46.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-345DEG1440(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 345.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 313.7 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.4 V / 9.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.301 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.58% (1.962 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-345DEG1440(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-345DEG1440(II).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.21 kW 380 sq ft $1,554 $2,628
8 kW Class 24 8.28 kW 507 sq ft $2,072 $3,504
10 kW Class 29 10.01 kW 612 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-345DEG1440(II) series guide.

Sibling CEC listings grouped into the Trina Solar TSM-345DEG1440(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-340DEG1440(II) 340.0 W 309.0 W 46.5 V 38.2 V 17.33%
Trina Solar TSM-345DEG1440(II) 345.0 W 313.7 W 46.7 V 38.4 V 17.58%

How Many Trina Solar TSM-345DEG1440(II) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-345DEG1440(II) (46.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=46.7V and beta_Voc=-0.301%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.03 V 11 panels 583.3 V 18 panels
-10 C (14 F) 51.62 V 11 panels 567.8 V 19 panels
0 C (32 F) 50.21 V 11 panels 552.3 V 19 panels
25 C (77 F STC) 46.7 V 12 panels 560.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-345DEG1440(II)?

Four comparable CEC modules such as GCL System Integration Technology Co Ltd GCL-M6/72345 (345.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/72345
GCL System Integration Technology Co Ltd
345.0 W Tie (0 W) 46.8 V 17.78% 90.5%
GCL System Integration Technology Co Ltd GCL-P3/72H345
GCL System Integration Technology Co Ltd
345.0 W Tie (0 W) 46.88 V 17.16% 93.1%
AXITEC AC-345M/156-72S
AXITEC
345.0 W Tie (0 W) 47.0 V 17.78% 91.4%
GCL System Integration Technology Co Ltd GCL-P6/72345
GCL System Integration Technology Co Ltd
345.0 W Tie (0 W) 47.3 V 17.78% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-345DEG1440(II)?

Evaluate Trina Solar TSM-345DEG1440(II) (345.0 W STC, 46.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-345DEG1440(II) reaches 53.03 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 507 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (507 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-345DEG1440(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-345DEG1440(II) 8 kW Residential Fit

Needs 24 modules (507 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72345.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 313.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-345DEG1440(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-345DEG1440(II) panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-345DEG1440(II) cold Voc rises from 46.7 V to 51.62 V (beta_Voc -0.301%/C), capping a 600 V string at 11 panels (567.8 V).

How much roof area does an 8 kW array of Trina Solar TSM-345DEG1440(II) need?

An 8 kW DC system uses 24 Trina Solar TSM-345DEG1440(II) modules (8,280 W STC / 7,529 W PTC), covering roughly 507 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

How does Trina Solar TSM-345DEG1440(II) compare against GCL System Integration Technology Co Ltd GCL-M6/72345?

Trina Solar TSM-345DEG1440(II) outputs 345.0 W STC (46.7 V Voc, rank #13,309 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/72345 delivers 345.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.