Trina Solar TSM-345DEG14(II) is a 345.0 W STC (313.7 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.58% efficiency, 46.7 V Voc at 25 C, and 51.62 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 345.0 W
- PTC Wattage
- 313.7 W
- Voc @ 25C
- 46.7 V
- Efficiency
- 17.58%
How Does Trina Solar TSM-345DEG14(II) Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-345DEG14(II) (Mono-c-Si) residential solar systems.
Homeowners evaluating Trina Solar TSM-345DEG14(II) need 18 panels for 6 kW or 24 panels (507 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (507 sq ft). Under NEC 690.7(A), beta_Voc (-0.301%/C) pushes open-circuit voltage to 51.62 V at 14 F and 53.03 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Trina Solar TSM-345DEG14(II) Fall Across Listed CEC Models?
Comparison of Trina Solar TSM-345DEG14(II) (345.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Trina Solar TSM-345DEG14(II)?
Relative ranking of Trina Solar TSM-345DEG14(II) across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Trina Solar TSM-345DEG14(II)?
Summary of Trina Solar TSM-345DEG14(II) output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.
345.0 W STC · Higher Than 37.4%
345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.58% Aperture Efficiency
Power density 175.8 W/m2 (2.33 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.62 V at -10 C (567.8 V string) and 53.03 V at -20 C (11 max).
24 Panels = 8,280 W STC
Occupies 47.1 m2 (507 sq ft) producing 7,529 W PTC; NEC 690.8 OCPD floor is 14.82 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.7 * (1 + (-0.301/100) * (-10 - 25)) = 51.62 V | OCPD = 1.56 * 9.5 = 14.82 A
Inputs from CEC Modules.csv for Trina Solar TSM-345DEG14(II): Voc=46.7 V, beta_Voc=-0.301%/C, Isc=9.5 A, STC=345.0 W, Area=1.962 m2.
Result: 11 panels max on 600 V (567.8 V); 24 panels for 8 kW (507 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-345DEG14(II)?
Complete CEC test sheet for Trina Solar TSM-345DEG14(II) including Isc (9.5 A), Voc (46.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 313.7 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.4 V / 9.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.301 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.58% (1.962 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-345DEG14(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-345DEG14(II).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.21 kW | 380 sq ft | $1,554 | $2,628 |
| 8 kW Class | 24 | 8.28 kW | 507 sq ft | $2,072 | $3,504 |
| 10 kW Class | 29 | 10.01 kW | 612 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-345DEG14(II) series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-340DEG14(II) | 340.0 W | 309.0 W | 46.5 V | 38.2 V | 17.33% |
| Trina Solar TSM-345DEG14(II) | 345.0 W | 313.7 W | 46.7 V | 38.4 V | 17.58% |
How Many Trina Solar TSM-345DEG14(II) Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Trina Solar TSM-345DEG14(II) (46.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.03 V | 11 panels | 583.3 V | 18 panels |
| -10 C (14 F) | 51.62 V | 11 panels | 567.8 V | 19 panels |
| 0 C (32 F) | 50.21 V | 11 panels | 552.3 V | 19 panels |
| 25 C (77 F STC) | 46.7 V | 12 panels | 560.4 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-345DEG14(II)?
Four comparable CEC modules such as GCL System Integration Technology Co Ltd GCL-M6/72345 (345.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.8 V | 17.78% | 90.5% |
| GCL System Integration Technology Co Ltd GCL-P3/72H345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.88 V | 17.16% | 93.1% |
| AXITEC AC-345M/156-72S AXITEC |
345.0 W | Tie (0 W) | 47.0 V | 17.78% | 91.4% |
| GCL System Integration Technology Co Ltd GCL-P6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 47.3 V | 17.78% | 91.6% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-345DEG14(II)?
Evaluate Trina Solar TSM-345DEG14(II) (345.0 W STC, 46.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-345DEG14(II) reaches 53.03 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 507 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (507 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-345DEG14(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-345DEG14(II) 8 kW Residential Fit
Needs 24 modules (507 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72345.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 313.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-345DEG14(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Trina Solar TSM-345DEG14(II) PTC wattage (313.7 W) lower than STC (345.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 313.7 W PTC (90.9% retention) across Trina Solar TSM-345DEG14(II)'s 1.962 m2 aperture.
Who should skip Trina Solar TSM-345DEG14(II) on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Trina Solar TSM-345DEG14(II) panels (507 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-M6/72345.
What is the 1,000 V commercial string limit for Trina Solar TSM-345DEG14(II)?
On 1,000 V commercial inverters at -10 C (51.62 V cold Voc), Trina Solar TSM-345DEG14(II) fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-345DEG14(II).
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)