Trina Solar TSM-320PDG14 is a 320.0 W STC (285.1 W PTC) Multi-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 16.31% efficiency, 45.9 V Voc at 25 C, and 51.68 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 320.0 W
- PTC Wattage
- 285.1 W
- Voc @ 25C
- 45.9 V
- Efficiency
- 16.31%
How Does Trina Solar TSM-320PDG14 Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-320PDG14: PTC thermal retention, roof footprint, and cold Voc string bounds. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Across 1,407 Multi-c-Si listings from Trina Solar and peers, Trina Solar TSM-320PDG14 stands 41.2 W above the 278.8 W Multi-c-Si median and typical 89.1% PTC-to-STC thermal output (285.1 W real-world rating). Sizing 6 kW (19 panels) to 10 kW (32 panels) yields $1,522-$2,563/yr in baseline US bill offset. Mid-range 45.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Trina Solar TSM-320PDG14 Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-320PDG14 (320.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define Trina Solar TSM-320PDG14?
Dataset percentiles tracking Trina Solar TSM-320PDG14 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for Trina Solar TSM-320PDG14?
Benchmark highlights for Trina Solar TSM-320PDG14 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
320.0 W STC · Higher Than 29.0%
320.0 W STC (-65.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.31% Aperture Efficiency
Power density 163.1 W/m2 (3.60 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.68 V at -10 C (568.5 V string) and 53.34 V at -20 C (11 max).
25 Panels = 8,000 W STC
Occupies 49.0 m2 (528 sq ft) producing 7,128 W PTC; NEC 690.8 OCPD floor is 14.15 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.9 * (1 + (-0.36/100) * (-10 - 25)) = 51.68 V | OCPD = 1.56 * 9.07 = 14.15 A
Inputs from CEC Modules.csv for Trina Solar TSM-320PDG14: Voc=45.9 V, beta_Voc=-0.36%/C, Isc=9.07 A, STC=320.0 W, Area=1.962 m2.
Result: 11 panels max on 600 V (568.5 V); 25 panels for 8 kW (528 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-320PDG14?
Official CEC datasheet figures for Trina Solar TSM-320PDG14 (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 320.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 285.1 W (89.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.2 V / 8.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.31% (1.962 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-320PDG14 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-320PDG14 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.08 kW | 401 sq ft | $1,522 | $2,573 |
| 8 kW Class | 25 | 8.0 kW | 528 sq ft | $2,002 | $3,386 |
| 10 kW Class | 32 | 10.24 kW | 676 sq ft | $2,563 | $4,334 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Consolidated Trina Solar wattage variants sharing the Trina Solar TSM-320PDG14 mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-315PDG14 | 315.0 W | 280.5 W | 45.6 V | 37.1 V | 16.05% |
| Trina Solar TSM-320PDG14 | 320.0 W | 285.1 W | 45.9 V | 37.2 V | 16.31% |
How Many Trina Solar TSM-320PDG14 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-320PDG14 (51.68 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.34 V | 11 panels | 586.7 V | 18 panels |
| -10 C (14 F) | 51.68 V | 11 panels | 568.5 V | 19 panels |
| 0 C (32 F) | 50.03 V | 11 panels | 550.3 V | 19 panels |
| 25 C (77 F STC) | 45.9 V | 13 panels | 596.7 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-320PDG14?
Competing CEC solar panels closest to Trina Solar TSM-320PDG14 in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
320.0 W | Tie (0 W) | 45.94 V | 16.64% | 91.2% |
| AXITEC AC-320P/72S AXITEC |
320.0 W | Tie (0 W) | 45.82 V | 16.58% | 92.2% |
| AXITEC AC-320P/72V AXITEC |
320.0 W | Tie (0 W) | 45.82 V | 16.58% | 92.2% |
| AXITEC AC-320P/72X AXITEC |
320.0 W | Tie (0 W) | 45.82 V | 16.58% | 90.7% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-320PDG14?
Evaluate Trina Solar TSM-320PDG14 (320.0 W STC, 45.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-320PDG14 reaches 53.34 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 528 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (528 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-320PDG14 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-320PDG14 8 kW Residential Fit
Needs 25 modules (528 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 285.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-320PDG14 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-320PDG14?
Multiplying Trina Solar TSM-320PDG14's 9.07 A short-circuit current by 1.56 equals 14.15 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Trina Solar TSM-320PDG14 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.68 V cold Voc at 14 F and handles 9.07 A Isc; string inverters cap Trina Solar TSM-320PDG14 at 11 panels on 600 V.
Is Trina Solar TSM-320PDG14 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-320PDG14 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)