Trina Solar TSM-320PD1408S — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-320PD1408S is a 320.0 W STC (292.0 W PTC) Multi-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 16.49% efficiency, 45.8 V Voc at 25 C, and 50.79 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
320.0 W
PTC Wattage
292.0 W
Voc @ 25C
45.8 V
Efficiency
16.49%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-320PD1408S Compare Against Peer CEC Listings?

Solar engineering breakdown for Trina Solar TSM-320PD1408S: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Measured at 320.0 W STC and 292.0 W PTC, Trina Solar TSM-320PD1408S sits -65.0 W vs all-CEC median (below all-CEC median; higher than 29.0% of peers) among 21,677 listed modules. Power density reaches 164.9 W/m2 (3.42 percentage points below 19.91% CEC median). Mid-range 45.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-P6/72320 rates 320.0 W.

Where Does Trina Solar TSM-320PD1408S Fall Across Listed CEC Models?

Distribution marker showing Trina Solar TSM-320PD1408S (320.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-320PD1408S (320.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-32: 320.0 W

What Dataset Percentiles Define Trina Solar TSM-320PD1408S?

Dataset percentiles tracking Trina Solar TSM-320PD1408S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Trina Solar TSM-320PD1408S Engineering BenchmarksPercentile comparison of Trina Solar TSM-320PD1408S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage320.0 WPTC/STC Retention91.2%Module Efficiency16.49%

What Do the Dataset Ranks Show for Trina Solar TSM-320PD1408S?

Benchmark highlights for Trina Solar TSM-320PD1408S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #14,944 / 21,677

320.0 W STC · Higher Than 29.0%

320.0 W STC (-65.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,316

16.49% Aperture Efficiency

Power density 164.9 W/m2 (3.42 percentage points below 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.79 V at -10 C (558.7 V string) and 52.21 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,000 W STC

Occupies 48.5 m2 (522 sq ft) producing 7,300 W PTC; NEC 690.8 OCPD floor is 14.2 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.8 * (1 + (-0.311/100) * (-10 - 25)) = 50.79 V | OCPD = 1.56 * 9.1 = 14.2 A

Inputs from CEC Modules.csv for Trina Solar TSM-320PD1408S: Voc=45.8 V, beta_Voc=-0.311%/C, Isc=9.1 A, STC=320.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (558.7 V); 25 panels for 8 kW (522 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-320PD1408S?

Official CEC datasheet figures for Trina Solar TSM-320PD1408S (Multi-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-320PD1408S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 320.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 292.0 W (91.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.1 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.1 V / 8.63 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.311 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.49% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-320PD1408S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Trina Solar TSM-320PD1408S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.08 kW 397 sq ft $1,522 $2,573
8 kW Class 25 8.0 kW 522 sq ft $2,002 $3,386
10 kW Class 32 10.24 kW 668 sq ft $2,563 $4,334

How Many Trina Solar TSM-320PD1408S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-320PD1408S (50.79 V at 14 F).

Computed from Voc=45.8V and beta_Voc=-0.311%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.21 V 11 panels 574.3 V 19 panels
-10 C (14 F) 50.79 V 11 panels 558.7 V 19 panels
0 C (32 F) 49.36 V 12 panels 592.3 V 20 panels
25 C (77 F STC) 45.8 V 13 panels 595.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-320PD1408S?

Competing CEC solar panels closest to Trina Solar TSM-320PD1408S in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/72320.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/72320
GCL System Integration Technology Co Ltd
320.0 W Tie (0 W) 45.8 V 16.49% 90.6%
GCL System Integration Technology Co Ltd GCL-P6/72B320
GCL System Integration Technology Co Ltd
320.0 W Tie (0 W) 45.8 V 16.49% 90.2%
AXITEC AC-320P/72S
AXITEC
320.0 W Tie (0 W) 45.82 V 16.58% 92.2%
AXITEC AC-320P/72V
AXITEC
320.0 W Tie (0 W) 45.82 V 16.58% 92.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-320PD1408S?

Evaluate Trina Solar TSM-320PD1408S (320.0 W STC, 45.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-320PD1408S reaches 52.21 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-320PD1408S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-320PD1408S 8 kW Residential Fit

Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72320.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 292.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-320PD1408S by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-320PD1408S panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-320PD1408S cold Voc rises from 45.8 V to 50.79 V (beta_Voc -0.311%/C), capping a 600 V string at 11 panels (558.7 V).

How much roof area does an 8 kW array of Trina Solar TSM-320PD1408S need?

An 8 kW DC system uses 25 Trina Solar TSM-320PD1408S modules (8,000 W STC / 7,300 W PTC), covering roughly 522 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does Trina Solar TSM-320PD1408S compare against GCL System Integration Technology Co Ltd GCL-P6/72320?

Trina Solar TSM-320PD1408S outputs 320.0 W STC (45.8 V Voc, rank #14,944 of 21,677), while GCL System Integration Technology Co Ltd GCL-P6/72320 delivers 320.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.