Trina Solar TSM-320PD14052 is a 320.0 W STC (292.0 W PTC) Multi-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 16.49% efficiency, 45.8 V Voc at 25 C, and 50.79 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 320.0 W
- PTC Wattage
- 292.0 W
- Voc @ 25C
- 45.8 V
- Efficiency
- 16.49%
How Does Trina Solar TSM-320PD14052 Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-320PD14052: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Across 1,407 Multi-c-Si listings from Trina Solar and peers, Trina Solar TSM-320PD14052 stands 41.2 W above the 278.8 W Multi-c-Si median and typical 91.2% PTC-to-STC thermal output (292.0 W real-world rating). Sizing 6 kW (19 panels) to 10 kW (32 panels) yields $1,522-$2,563/yr in baseline US bill offset. Mid-range 45.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Trina Solar TSM-320PD14052 Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-320PD14052 (320.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define Trina Solar TSM-320PD14052?
Dataset percentiles tracking Trina Solar TSM-320PD14052 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for Trina Solar TSM-320PD14052?
Benchmark highlights for Trina Solar TSM-320PD14052 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
320.0 W STC · Higher Than 29.0%
320.0 W STC (-65.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.49% Aperture Efficiency
Power density 164.9 W/m2 (3.42 percentage points below 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.79 V at -10 C (558.7 V string) and 52.21 V at -20 C (11 max).
25 Panels = 8,000 W STC
Occupies 48.5 m2 (522 sq ft) producing 7,300 W PTC; NEC 690.8 OCPD floor is 14.2 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.8 * (1 + (-0.311/100) * (-10 - 25)) = 50.79 V | OCPD = 1.56 * 9.1 = 14.2 A
Inputs from CEC Modules.csv for Trina Solar TSM-320PD14052: Voc=45.8 V, beta_Voc=-0.311%/C, Isc=9.1 A, STC=320.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (558.7 V); 25 panels for 8 kW (522 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-320PD14052?
Official CEC datasheet figures for Trina Solar TSM-320PD14052 (Multi-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 320.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 292.0 W (91.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.1 V / 8.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.311 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.49% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-320PD14052 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-320PD14052 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.08 kW | 397 sq ft | $1,522 | $2,573 |
| 8 kW Class | 25 | 8.0 kW | 522 sq ft | $2,002 | $3,386 |
| 10 kW Class | 32 | 10.24 kW | 668 sq ft | $2,563 | $4,334 |
How Many Trina Solar TSM-320PD14052 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-320PD14052 (50.79 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.21 V | 11 panels | 574.3 V | 19 panels |
| -10 C (14 F) | 50.79 V | 11 panels | 558.7 V | 19 panels |
| 0 C (32 F) | 49.36 V | 12 panels | 592.3 V | 20 panels |
| 25 C (77 F STC) | 45.8 V | 13 panels | 595.4 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-320PD14052?
Competing CEC solar panels closest to Trina Solar TSM-320PD14052 in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-P6/72320.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-P6/72320 GCL System Integration Technology Co Ltd |
320.0 W | Tie (0 W) | 45.8 V | 16.49% | 90.6% |
| GCL System Integration Technology Co Ltd GCL-P6/72B320 GCL System Integration Technology Co Ltd |
320.0 W | Tie (0 W) | 45.8 V | 16.49% | 90.2% |
| AXITEC AC-320P/72S AXITEC |
320.0 W | Tie (0 W) | 45.82 V | 16.58% | 92.2% |
| AXITEC AC-320P/72V AXITEC |
320.0 W | Tie (0 W) | 45.82 V | 16.58% | 92.2% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-320PD14052?
Evaluate Trina Solar TSM-320PD14052 (320.0 W STC, 45.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-320PD14052 reaches 52.21 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-320PD14052 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-320PD14052 8 kW Residential Fit
Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72320.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 292.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-320PD14052 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-320PD14052?
Multiplying Trina Solar TSM-320PD14052's 9.1 A short-circuit current by 1.56 equals 14.2 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Trina Solar TSM-320PD14052 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.79 V cold Voc at 14 F and handles 9.1 A Isc; string inverters cap Trina Solar TSM-320PD14052 at 11 panels on 600 V.
Is Trina Solar TSM-320PD14052 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-320PD14052 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)