Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-270DE061MT8(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-270DE061MT8(II) is a 270.0 W STC (249.6 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.67% efficiency, 33.0 V Voc at 25 C, and 36.06 V cold Voc at -10 C (16 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
249.6 W
Voc @ 25C
33.0 V
Efficiency
16.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-270DE061MT8(II) Compare Against Peer CEC Listings?

Solar engineering breakdown for Trina Solar TSM-270DE061MT8(II): PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 270.0 W STC and 249.6 W PTC, Trina Solar TSM-270DE061MT8(II) sits -115.0 W vs all-CEC median (below all-CEC median; higher than 12.9% of peers) among 21,677 listed modules. Power density reaches 166.7 W/m2 (3.24 percentage points below 19.91% CEC median). Lower 33.0 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 27 panels in series. Alternative peer CSI Solar Co Ltd CS6PH-260P rates 260.0 W.

Where Does Trina Solar TSM-270DE061MT8(II) Fall Across Listed CEC Models?

Distribution marker showing Trina Solar TSM-270DE061MT8(II) (270.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-270DE061MT8(II) (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-27: 270.0 W

What Dataset Percentiles Define Trina Solar TSM-270DE061MT8(II)?

Dataset percentiles tracking Trina Solar TSM-270DE061MT8(II) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Trina Solar TSM-270DE061MT8(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-270DE061MT8(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention92.4%Module Efficiency16.67%

What Do the Dataset Ranks Show for Trina Solar TSM-270DE061MT8(II)?

Benchmark highlights for Trina Solar TSM-270DE061MT8(II) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,034

16.67% Aperture Efficiency

Power density 166.7 W/m2 (3.24 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

16 Panels Max @ -10 C (600 V)

Cold Voc reaches 36.06 V at -10 C (577.0 V string) and 36.94 V at -20 C (16 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 48.6 m2 (523 sq ft) producing 7,488 W PTC; NEC 690.8 OCPD floor is 16.27 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.0 * (1 + (-0.265/100) * (-10 - 25)) = 36.06 V | OCPD = 1.56 * 10.43 = 16.27 A

Inputs from CEC Modules.csv for Trina Solar TSM-270DE061MT8(II): Voc=33.0 V, beta_Voc=-0.265%/C, Isc=10.43 A, STC=270.0 W, Area=1.62 m2.

Result: 16 panels max on 600 V (577.0 V); 30 panels for 8 kW (523 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-270DE061MT8(II)?

Official CEC datasheet figures for Trina Solar TSM-270DE061MT8(II) (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-270DE061MT8(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 249.6 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 33.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.43 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 27.4 V / 9.87 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.265 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.67% (1.62 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-270DE061MT8(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Trina Solar TSM-270DE061MT8(II) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 401 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 523 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 663 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Consolidated Trina Solar wattage variants sharing the Trina Solar TSM-270DE061MT8(II) mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Trina Solar TSM-270DE061MT8(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-265DE061MT8(II) 265.0 W 244.8 W 32.8 V 27.1 V 16.36%
Trina Solar TSM-270DE061MT8(II) 270.0 W 249.6 W 33.0 V 27.4 V 16.67%

How Many Trina Solar TSM-270DE061MT8(II) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-270DE061MT8(II) (36.06 V at 14 F).

Computed from Voc=33.0V and beta_Voc=-0.265%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 36.94 V 16 panels 591.0 V 27 panels
-10 C (14 F) 36.06 V 16 panels 577.0 V 27 panels
0 C (32 F) 35.19 V 17 panels 598.2 V 28 panels
25 C (77 F STC) 33.0 V 18 panels 594.0 V 30 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-270DE061MT8(II)?

Competing CEC solar panels closest to Trina Solar TSM-270DE061MT8(II) in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6PH-260P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6PH-260P
CSI Solar Co Ltd
260.0 W -10.0 W 34.6 V 16.77% 92.8%
CSI Solar Co Ltd CS6PH-280P
CSI Solar Co Ltd
280.0 W +10.0 W 35.4 V 18.06% 93.0%
GermanSolar USA Inc GSP-270W
GermanSolar USA Inc
270.0 W Tie (0 W) 37.92 V 16.27% 92.0%
GCL System Integration Technology Co Ltd GCL-P6/60270
GCL System Integration Technology Co Ltd
270.0 W Tie (0 W) 38.3 V 16.6% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-270DE061MT8(II)?

Evaluate Trina Solar TSM-270DE061MT8(II) (270.0 W STC, 33.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-270DE061MT8(II) reaches 36.94 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (523 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-270DE061MT8(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-270DE061MT8(II) 8 kW Residential Fit

Needs 30 modules (523 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare CSI Solar Co Ltd CS6PH-260P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 249.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-270DE061MT8(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-270DE061MT8(II) panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-270DE061MT8(II) cold Voc rises from 33.0 V to 36.06 V (beta_Voc -0.265%/C), capping a 600 V string at 16 panels (577.0 V).

How much roof area does an 8 kW array of Trina Solar TSM-270DE061MT8(II) need?

An 8 kW DC system uses 30 Trina Solar TSM-270DE061MT8(II) modules (8,100 W STC / 7,488 W PTC), covering roughly 523 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Trina Solar TSM-270DE061MT8(II) compare against CSI Solar Co Ltd CS6PH-260P?

Trina Solar TSM-270DE061MT8(II) outputs 270.0 W STC (33.0 V Voc, rank #18,572 of 21,677), while CSI Solar Co Ltd CS6PH-260P delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.