Trina Solar TSM-270DD061M08(II) is a 270.0 W STC (249.6 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.67% efficiency, 33.0 V Voc at 25 C, and 36.06 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 249.6 W
- Voc @ 25C
- 33.0 V
- Efficiency
- 16.67%
How Does Trina Solar TSM-270DD061M08(II) Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-270DD061M08(II) (Mono-c-Si) residential solar systems.
Trina Solar TSM-270DD061M08(II) delivers 166.7 W/m2 (3.24 percentage points below 19.91% CEC median) and strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (523 sq ft). At -4 F (-20 C), string voltage climbs to 36.94 V per unit, capping 600 V circuits at 16 panels. Compare specs directly with CSI Solar Co Ltd CS6PH-260P (260.0 W).
Where Does Trina Solar TSM-270DD061M08(II) Fall Across Listed CEC Models?
Comparison of Trina Solar TSM-270DD061M08(II) (270.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Trina Solar TSM-270DD061M08(II)?
Relative ranking of Trina Solar TSM-270DD061M08(II) across nameplate watts, 92.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Trina Solar TSM-270DD061M08(II)?
Summary of Trina Solar TSM-270DD061M08(II) output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.67% Aperture Efficiency
Power density 166.7 W/m2 (3.24 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 36.06 V at -10 C (577.0 V string) and 36.94 V at -20 C (16 max).
30 Panels = 8,100 W STC
Occupies 48.6 m2 (523 sq ft) producing 7,488 W PTC; NEC 690.8 OCPD floor is 16.27 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 33.0 * (1 + (-0.265/100) * (-10 - 25)) = 36.06 V | OCPD = 1.56 * 10.43 = 16.27 A
Inputs from CEC Modules.csv for Trina Solar TSM-270DD061M08(II): Voc=33.0 V, beta_Voc=-0.265%/C, Isc=10.43 A, STC=270.0 W, Area=1.62 m2.
Result: 16 panels max on 600 V (577.0 V); 30 panels for 8 kW (523 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-270DD061M08(II)?
Complete CEC test sheet for Trina Solar TSM-270DD061M08(II) including Isc (10.43 A), Voc (33.0 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 249.6 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 33.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.43 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 27.4 V / 9.87 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.265 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.67% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-270DD061M08(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-270DD061M08(II).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 401 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 523 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 663 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-270DD061M08(II) series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-265DD061M08(II) | 265.0 W | 244.8 W | 32.8 V | 27.1 V | 16.36% |
| Trina Solar TSM-270DD061M08(II) | 270.0 W | 249.6 W | 33.0 V | 27.4 V | 16.67% |
How Many Trina Solar TSM-270DD061M08(II) Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Trina Solar TSM-270DD061M08(II) (33.0 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 36.94 V | 16 panels | 591.0 V | 27 panels |
| -10 C (14 F) | 36.06 V | 16 panels | 577.0 V | 27 panels |
| 0 C (32 F) | 35.19 V | 17 panels | 598.2 V | 28 panels |
| 25 C (77 F STC) | 33.0 V | 18 panels | 594.0 V | 30 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-270DD061M08(II)?
Four comparable CEC modules such as CSI Solar Co Ltd CS6PH-260P (260.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6PH-260P CSI Solar Co Ltd |
260.0 W | -10.0 W | 34.6 V | 16.77% | 92.8% |
| CSI Solar Co Ltd CS6PH-280P CSI Solar Co Ltd |
280.0 W | +10.0 W | 35.4 V | 18.06% | 93.0% |
| GermanSolar USA Inc GSP-270W GermanSolar USA Inc |
270.0 W | Tie (0 W) | 37.92 V | 16.27% | 92.0% |
| GCL System Integration Technology Co Ltd GCL-P6/60270 GCL System Integration Technology Co Ltd |
270.0 W | Tie (0 W) | 38.3 V | 16.6% | 90.6% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-270DD061M08(II)?
Evaluate Trina Solar TSM-270DD061M08(II) (270.0 W STC, 33.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-270DD061M08(II) reaches 36.94 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (523 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-270DD061M08(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-270DD061M08(II) 8 kW Residential Fit
Needs 30 modules (523 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare CSI Solar Co Ltd CS6PH-260P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 249.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-270DD061M08(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Trina Solar TSM-270DD061M08(II) panels fit on a 600 V winter solar string?
At -10 C (14 F), Trina Solar TSM-270DD061M08(II) cold Voc rises from 33.0 V to 36.06 V (beta_Voc -0.265%/C), capping a 600 V string at 16 panels (577.0 V).
How much roof area does an 8 kW array of Trina Solar TSM-270DD061M08(II) need?
An 8 kW DC system uses 30 Trina Solar TSM-270DD061M08(II) modules (8,100 W STC / 7,488 W PTC), covering roughly 523 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Trina Solar TSM-270DD061M08(II) compare against CSI Solar Co Ltd CS6PH-260P?
Trina Solar TSM-270DD061M08(II) outputs 270.0 W STC (33.0 V Voc, rank #18,572 of 21,677), while CSI Solar Co Ltd CS6PH-260P delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)