Trina Solar TSM-260PD0508D is a 260.0 W STC (236.9 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.07% efficiency, 37.9 V Voc at 25 C, and 42.54 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 236.9 W
- Voc @ 25C
- 37.9 V
- Efficiency
- 16.07%
How Does Trina Solar TSM-260PD0508D Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-260PD0508D: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Across 1,407 Multi-c-Si listings from Trina Solar and peers, Trina Solar TSM-260PD0508D stands 18.8 W below the 278.8 W Multi-c-Si median and typical 91.1% PTC-to-STC thermal output (236.9 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Lower 37.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Trina Solar TSM-260PD0508D Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-260PD0508D (260.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define Trina Solar TSM-260PD0508D?
Dataset percentiles tracking Trina Solar TSM-260PD0508D power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for Trina Solar TSM-260PD0508D?
Benchmark highlights for Trina Solar TSM-260PD0508D covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.07% Aperture Efficiency
Power density 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.54 V at -10 C (595.6 V string) and 43.87 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 50.2 m2 (540 sq ft) producing 7,344 W PTC; NEC 690.8 OCPD floor is 13.53 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.9 * (1 + (-0.35/100) * (-10 - 25)) = 42.54 V | OCPD = 1.56 * 8.67 = 13.53 A
Inputs from CEC Modules.csv for Trina Solar TSM-260PD0508D: Voc=37.9 V, beta_Voc=-0.35%/C, Isc=8.67 A, STC=260.0 W, Area=1.618 m2.
Result: 14 panels max on 600 V (595.6 V); 31 panels for 8 kW (540 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-260PD0508D?
Official CEC datasheet figures for Trina Solar TSM-260PD0508D (Multi-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 236.9 W (91.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.67 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.7 V / 8.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.35 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.07% (1.618 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-260PD0508D Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-260PD0508D modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 418 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 540 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 679 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Consolidated Trina Solar wattage variants sharing the Trina Solar TSM-260PD0508D mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-250PD0508D | 250.0 W | 227.5 W | 37.6 V | 31.0 V | 15.45% |
| Trina Solar TSM-255PD0508D | 255.0 W | 232.2 W | 37.7 V | 31.4 V | 15.76% |
| Trina Solar TSM-260PD0508D | 260.0 W | 236.9 W | 37.9 V | 31.7 V | 16.07% |
| Trina Solar TSM-265PD0508D | 265.0 W | 243.2 W | 38.3 V | 30.8 V | 16.37% |
| Trina Solar TSM-270PD0508D | 270.0 W | 242.7 W | 38.4 V | 30.9 V | 16.5% |
How Many Trina Solar TSM-260PD0508D Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-260PD0508D (42.54 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.87 V | 13 panels | 570.3 V | 22 panels |
| -10 C (14 F) | 42.54 V | 14 panels | 595.6 V | 23 panels |
| 0 C (32 F) | 41.22 V | 14 panels | 577.1 V | 24 panels |
| 25 C (77 F STC) | 37.9 V | 15 panels | 568.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-260PD0508D?
Competing CEC solar panels closest to Trina Solar TSM-260PD0508D in nameplate wattage and Voc, starting with Centrosolar America TP6 260xx.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America TP6 260xx Centrosolar America |
260.0 W | Tie (0 W) | 37.9 V | 15.92% | 90.1% |
| Centrosolar America TP6S 260xx Centrosolar America |
260.0 W | Tie (0 W) | 37.9 V | 15.92% | 90.1% |
| GCL System Integration Technology Co Ltd GCL-P6/60260 GCL System Integration Technology Co Ltd |
260.0 W | Tie (0 W) | 37.9 V | 15.98% | 90.5% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
260.0 W | Tie (0 W) | 38.0 V | 16.01% | 88.5% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-260PD0508D?
Evaluate Trina Solar TSM-260PD0508D (260.0 W STC, 37.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-260PD0508D reaches 43.87 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 540 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (540 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-260PD0508D carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-260PD0508D 8 kW Residential Fit
Needs 31 modules (540 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TP6 260xx.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 236.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-260PD0508D by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-260PD0508D?
Multiplying Trina Solar TSM-260PD0508D's 8.67 A short-circuit current by 1.56 equals 13.53 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Trina Solar TSM-260PD0508D pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.54 V cold Voc at 14 F and handles 8.67 A Isc; string inverters cap Trina Solar TSM-260PD0508D at 14 panels on 600 V.
Is Trina Solar TSM-260PD0508D eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-260PD0508D rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)