Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-260PD0500M — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-260PD0500M is a 260.0 W STC (236.9 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.07% efficiency, 37.9 V Voc at 25 C, and 42.54 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
236.9 W
Voc @ 25C
37.9 V
Efficiency
16.07%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-260PD0500M Compare Against Peer CEC Listings?

Engineering position of Trina Solar TSM-260PD0500M (260.0 W STC) vs. Centrosolar America TP6 260xx across 1,407 CEC Multi-c-Si solar modules.

Ranking #19,146 across 21,677 CEC solar panels (below all-CEC median; higher than 10.4% of peers), Trina Solar TSM-260PD0500M operates as a compact residential or specialty off-grid module sitting 18.8 W below the 278.8 W Multi-c-Si median. Lower 37.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 91.1% PTC-to-STC thermal output (236.9 W real-world rating), 31 panels occupy 540 sq ft and offset roughly $2,017/yr at average US rates (or $3,411/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-260PD0500M Fall Across Listed CEC Models?

Plots Trina Solar TSM-260PD0500M at 260.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-260PD0500M (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-26: 260.0 W

What Dataset Percentiles Define Trina Solar TSM-260PD0500M?

Benchmarks Trina Solar TSM-260PD0500M on STC wattage, thermal PTC/STC retention, and 16.07 aperture conversion efficiency against CEC peers.

Trina Solar TSM-260PD0500M Engineering BenchmarksPercentile comparison of Trina Solar TSM-260PD0500M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention91.1%Module Efficiency16.07%

What Do the Dataset Ranks Show for Trina Solar TSM-260PD0500M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-260PD0500M by Trina Solar.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,013

16.07% Aperture Efficiency

Power density 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.54 V at -10 C (595.6 V string) and 43.87 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 50.2 m2 (540 sq ft) producing 7,344 W PTC; NEC 690.8 OCPD floor is 13.53 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.9 * (1 + (-0.35/100) * (-10 - 25)) = 42.54 V | OCPD = 1.56 * 8.67 = 13.53 A

Inputs from CEC Modules.csv for Trina Solar TSM-260PD0500M: Voc=37.9 V, beta_Voc=-0.35%/C, Isc=8.67 A, STC=260.0 W, Area=1.618 m2.

Result: 14 panels max on 600 V (595.6 V); 31 panels for 8 kW (540 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-260PD0500M?

Laboratory test ratings recorded for Trina Solar TSM-260PD0500M (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-260PD0500M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 236.9 W (91.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.67 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.7 V / 8.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.35 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.07% (1.618 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-260PD0500M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (540 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-260PD0500M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 418 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 540 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 679 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Sibling wattage bins and frame colors grouped with Trina Solar TSM-260PD0500M under Trina Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Trina Solar TSM-260PD0500M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-250PD0500M 250.0 W 227.5 W 37.6 V 31.0 V 15.45%
Trina Solar TSM-255PD0500M 255.0 W 232.2 W 37.7 V 31.4 V 15.76%
Trina Solar TSM-260PD0500M 260.0 W 236.9 W 37.9 V 31.7 V 16.07%
Trina Solar TSM-265PD0500M 265.0 W 243.2 W 38.3 V 30.8 V 16.37%
Trina Solar TSM-270PD0500M 270.0 W 242.7 W 38.4 V 30.9 V 16.5%

How Many Trina Solar TSM-260PD0500M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Trina Solar TSM-260PD0500M (beta_Voc -0.35%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.9V and beta_Voc=-0.35%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.87 V 13 panels 570.3 V 22 panels
-10 C (14 F) 42.54 V 14 panels 595.6 V 23 panels
0 C (32 F) 41.22 V 14 panels 577.1 V 24 panels
25 C (77 F STC) 37.9 V 15 panels 568.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-260PD0500M?

Closest cross-brand CEC competitors to Trina Solar TSM-260PD0500M matched near 260.0 W STC and 37.9 V Voc, led by Centrosolar America TP6 260xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TP6 260xx
Centrosolar America
260.0 W Tie (0 W) 37.9 V 15.92% 90.1%
Centrosolar America TP6S 260xx
Centrosolar America
260.0 W Tie (0 W) 37.9 V 15.92% 90.1%
GCL System Integration Technology Co Ltd GCL-P6/60260
GCL System Integration Technology Co Ltd
260.0 W Tie (0 W) 37.9 V 15.98% 90.5%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
260.0 W Tie (0 W) 38.0 V 16.01% 88.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-260PD0500M?

Evaluate Trina Solar TSM-260PD0500M (260.0 W STC, 37.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-260PD0500M reaches 43.87 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 540 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (540 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-260PD0500M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-260PD0500M 8 kW Residential Fit

Needs 31 modules (540 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TP6 260xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 236.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-260PD0500M by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-260PD0500M panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-260PD0500M cold Voc rises from 37.9 V to 42.54 V (beta_Voc -0.35%/C), capping a 600 V string at 14 panels (595.6 V).

How much roof area does an 8 kW array of Trina Solar TSM-260PD0500M need?

An 8 kW DC system uses 31 Trina Solar TSM-260PD0500M modules (8,060 W STC / 7,344 W PTC), covering roughly 540 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Trina Solar TSM-260PD0500M compare against Centrosolar America TP6 260xx?

Trina Solar TSM-260PD0500M outputs 260.0 W STC (37.9 V Voc, rank #19,146 of 21,677), while Centrosolar America TP6 260xx delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.