Trina Solar TSM-170DA01 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-170DA01 is a 170.0 W STC (153.8 W PTC) Mono-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 13.47% efficiency, 43.6 V Voc at 25 C, and 48.48 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
170.0 W
PTC Wattage
153.8 W
Voc @ 25C
43.6 V
Efficiency
13.47%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-170DA01 Compare Against Peer CEC Listings?

Engineering position of Trina Solar TSM-170DA01 (170.0 W STC) vs. Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-170 across 5,889 CEC Mono-c-Si solar modules.

Ranking #21,323 across 21,677 CEC solar panels (below all-CEC median; higher than 1.5% of peers), Trina Solar TSM-170DA01 operates as a compact residential or specialty off-grid module sitting 240.0 W below the 410.0 W Mono-c-Si median. Mid-range 43.6 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With typical 90.5% PTC-to-STC thermal output (153.8 W real-world rating), 48 panels occupy 652 sq ft and offset roughly $2,042/yr at average US rates (or $3,454/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-170DA01 Fall Across Listed CEC Models?

Plots Trina Solar TSM-170DA01 at 170.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-170DA01 (170.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-17: 170.0 W

What Dataset Percentiles Define Trina Solar TSM-170DA01?

Benchmarks Trina Solar TSM-170DA01 on STC wattage, thermal PTC/STC retention, and 13.47 aperture conversion efficiency against CEC peers.

Trina Solar TSM-170DA01 Engineering BenchmarksPercentile comparison of Trina Solar TSM-170DA01 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage170.0 WPTC/STC Retention90.5%Module Efficiency13.47%

What Do the Dataset Ranks Show for Trina Solar TSM-170DA01?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-170DA01 by Trina Solar.

Rank #21,323 / 21,677

170.0 W STC · Higher Than 1.5%

170.0 W STC (-215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,228

13.47% Aperture Efficiency

Power density 134.7 W/m2 (6.44 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.48 V at -10 C (581.8 V string) and 49.88 V at -20 C (12 max).

8 kW Reference Array

48 Panels = 8,160 W STC

Occupies 60.6 m2 (652 sq ft) producing 7,382 W PTC; NEC 690.8 OCPD floor is 8.19 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.6 * (1 + (-0.32/100) * (-10 - 25)) = 48.48 V | OCPD = 1.56 * 5.25 = 8.19 A

Inputs from CEC Modules.csv for Trina Solar TSM-170DA01: Voc=43.6 V, beta_Voc=-0.32%/C, Isc=5.25 A, STC=170.0 W, Area=1.262 m2.

Result: 12 panels max on 600 V (581.8 V); 48 panels for 8 kW (652 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-170DA01?

Laboratory test ratings recorded for Trina Solar TSM-170DA01 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-170DA01.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 170.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 153.8 W (90.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.25 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.8 V / 4.76 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.47% (1.262 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-170DA01 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (652 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-170DA01.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 36 6.12 kW 489 sq ft $1,532 $2,590
8 kW Class 48 8.16 kW 652 sq ft $2,042 $3,454
10 kW Class 59 10.03 kW 801 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Sibling wattage bins and frame colors grouped with Trina Solar TSM-170DA01 under Trina Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Trina Solar TSM-170DA01 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-165DA01 165.0 W 149.2 W 43.2 V 35.6 V 13.07%
Trina Solar TSM-170DA01 170.0 W 153.8 W 43.6 V 35.8 V 13.47%

How Many Trina Solar TSM-170DA01 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Trina Solar TSM-170DA01 (beta_Voc -0.32%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=43.6V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.88 V 12 panels 598.6 V 20 panels
-10 C (14 F) 48.48 V 12 panels 581.8 V 20 panels
0 C (32 F) 47.09 V 12 panels 565.1 V 21 panels
25 C (77 F STC) 43.6 V 13 panels 566.8 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-170DA01?

Closest cross-brand CEC competitors to Trina Solar TSM-170DA01 matched near 170.0 W STC and 43.6 V Voc, led by Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-170.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-170
Jinzhou Jinmao Photovoltaic Technology
170.0 W Tie (0 W) 43.75 V 13.32% 86.4%
Jiangyin Hareon Power HR-170W/24V
Jiangyin Hareon Power
170.0 W Tie (0 W) 43.8 V 13.32% 89.8%
Suntech Power STP170S-24/Ad+
Suntech Power
170.0 W Tie (0 W) 43.8 V 13.32% 89.1%
Suntech Power STP170S-24/Adb+
Suntech Power
170.0 W Tie (0 W) 43.8 V 13.32% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-170DA01?

Evaluate Trina Solar TSM-170DA01 (170.0 W STC, 43.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-170DA01 reaches 49.88 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 48 panels for an 8 kW build require 652 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (652 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-170DA01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-170DA01 8 kW Residential Fit

Needs 48 modules (652 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-170.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 153.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-170DA01 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-170DA01 panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-170DA01 cold Voc rises from 43.6 V to 48.48 V (beta_Voc -0.32%/C), capping a 600 V string at 12 panels (581.8 V).

How much roof area does an 8 kW array of Trina Solar TSM-170DA01 need?

An 8 kW DC system uses 48 Trina Solar TSM-170DA01 modules (8,160 W STC / 7,382 W PTC), covering roughly 652 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does Trina Solar TSM-170DA01 compare against Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-170?

Trina Solar TSM-170DA01 outputs 170.0 W STC (43.6 V Voc, rank #21,323 of 21,677), while Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-170 delivers 170.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.