Trina Solar CoLtd TSM-585NE19RC — CEC Solar Module Specifications

Manufacturer: Trina Solar CoLtd Registry: CEC Verified Engineering Specification

Trina Solar CoLtd TSM-585NE19RC is a 585.0 W STC (554.0 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 21.83% efficiency, 47.5 V Voc at 25 C, and 51.44 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
585.0 W
PTC Wattage
554.0 W
Voc @ 25C
47.5 V
Efficiency
21.83%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar CoLtd TSM-585NE19RC Compare Against Peer CEC Listings?

How Trina Solar CoLtd Trina Solar CoLtd TSM-585NE19RC handles rooftop heat (554.0 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar CoLtd builds the Trina Solar CoLtd TSM-585NE19RC (Mono-c-Si) as a large-format commercial and ground-mount module delivering 218.3 W/m2 (1.92 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS62-66TB-590H (590.0 W), this model holds strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677). Mid-range 47.5 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 24.46 A overcurrent floor served by a 25 A breaker.

Where Does Trina Solar CoLtd TSM-585NE19RC Fall Across Listed CEC Models?

Where Trina Solar CoLtd TSM-585NE19RC (585.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar CoLtd TSM-585NE19RC (585.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar CoLtd : 585.0 W

What Dataset Percentiles Define Trina Solar CoLtd TSM-585NE19RC?

Percentile placement of Trina Solar CoLtd TSM-585NE19RC across power density (218.3 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar CoLtd TSM-585NE19RC Engineering BenchmarksPercentile comparison of Trina Solar CoLtd TSM-585NE19RC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage585.0 WPTC/STC Retention94.7%Module Efficiency21.83%

What Do the Dataset Ranks Show for Trina Solar CoLtd TSM-585NE19RC?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar CoLtd TSM-585NE19RC specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #1,751 / 21,677

Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,538

21.83% Aperture Efficiency

Power density 218.3 W/m2 (1.92 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.44 V at -10 C (565.8 V string) and 52.57 V at -20 C (11 max).

8 kW Reference Array

14 Panels = 8,190 W STC

Occupies 37.5 m2 (404 sq ft) producing 7,756 W PTC; NEC 690.8 OCPD floor is 24.46 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.5 * (1 + (-0.237/100) * (-10 - 25)) = 51.44 V | OCPD = 1.56 * 15.68 = 24.46 A

Inputs from CEC Modules.csv for Trina Solar CoLtd TSM-585NE19RC: Voc=47.5 V, beta_Voc=-0.237%/C, Isc=15.68 A, STC=585.0 W, Area=2.68 m2.

Result: 11 panels max on 600 V (565.8 V); 14 panels for 8 kW (404 sq ft).

What Are the Published CEC Specifications for Trina Solar CoLtd TSM-585NE19RC?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar CoLtd TSM-585NE19RC.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar CoLtd TSM-585NE19RC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 585.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 554.0 W (94.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 15.68 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.5 V / 14.82 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.237 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.83% (2.68 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many Trina Solar CoLtd TSM-585NE19RC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar CoLtd TSM-585NE19RC (585.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.43 kW 317 sq ft $1,609 $2,721
8 kW Class 14 8.19 kW 404 sq ft $2,050 $3,466
10 kW Class 18 10.53 kW 519 sq ft $2,636 $4,457

Which Sibling Wattage & Trim Variants Belong to This Trina Solar CoLtd Series?

All closely matched Trina Solar CoLtd wattages and cosmetic trims sharing the Trina Solar CoLtd TSM-585NE19RC architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Trina Solar CoLtd TSM-585NE19RC wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar CoLtd TSM-575NE19RC 575.0 W 544.4 W 46.9 V 38.9 V 21.46%
Trina Solar CoLtd TSM-580NE19RC 580.0 W 549.2 W 47.2 V 39.2 V 21.64%
Trina Solar CoLtd TSM-585NE19RC 585.0 W 554.0 W 47.5 V 39.5 V 21.83%
Trina Solar CoLtd TSM-590NE19RC 590.0 W 558.9 W 47.8 V 39.7 V 22.01%
Trina Solar CoLtd TSM-595NE19RC 595.0 W 563.7 W 48.1 V 40.0 V 22.2%

How Many Trina Solar CoLtd TSM-585NE19RC Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar CoLtd TSM-585NE19RC from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.5V and beta_Voc=-0.237%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.57 V 11 panels 578.3 V 19 panels
-10 C (14 F) 51.44 V 11 panels 565.8 V 19 panels
0 C (32 F) 50.31 V 11 panels 553.4 V 19 panels
25 C (77 F STC) 47.5 V 12 panels 570.0 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar CoLtd TSM-585NE19RC?

Alternative CEC solar modules from competing brands near Trina Solar CoLtd TSM-585NE19RC (585.0 W), including CSI Solar Co Ltd CS62-66TB-590H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS62-66TB-590H
CSI Solar Co Ltd
590.0 W +5.0 W 47.2 V 22.52% 95.0%
CSI Solar Co Ltd CS62-66TB-590HR
CSI Solar Co Ltd
590.0 W +5.0 W 48.5 V 22.52% 94.6%
CSI Solar Co Ltd CS62-66TB-595HP
CSI Solar Co Ltd
595.0 W +10.0 W 47.4 V 22.71% 95.0%
Boviet Solar Technology Co Ltd BVM8611M-595R-H-HC-BF
Boviet Solar Technology Co Ltd
595.0 W +10.0 W 47.65 V 23.61% 95.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar CoLtd TSM-585NE19RC?

Evaluate Trina Solar CoLtd TSM-585NE19RC (585.0 W STC, 47.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar CoLtd TSM-585NE19RC reaches 52.57 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 404 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Trina Solar CoLtd TSM-585NE19RC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar CoLtd TSM-585NE19RC 8 kW Residential Fit

Needs 14 modules (404 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS62-66TB-590H.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 554.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar CoLtd TSM-585NE19RC by Trina Solar CoLtd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar CoLtd TSM-585NE19RC?

Multiplying Trina Solar CoLtd TSM-585NE19RC's 15.68 A short-circuit current by 1.56 equals 24.46 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Trina Solar CoLtd TSM-585NE19RC pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.44 V cold Voc at 14 F and handles 15.68 A Isc; string inverters cap Trina Solar CoLtd TSM-585NE19RC at 11 panels on 600 V.

Is Trina Solar CoLtd TSM-585NE19RC eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar CoLtd TSM-585NE19RC rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.