Skip to main content
WireAndSun
Calculators
CEC PV Module

Translucent Solar LLC SK9609MHVC-U-410 — CEC Solar Module Specifications

Manufacturer: Translucent Solar LLC Registry: CEC Verified Engineering Specification

Translucent Solar LLC SK9609MHVC-U-410 is a 410.0 W STC (384.3 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.14 V Voc at 25 C, and 41.12 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
384.3 W
Voc @ 25C
37.14 V
Efficiency
21.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Translucent Solar LLC SK9609MHVC-U-410 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Translucent Solar LLC SK9609MHVC-U-410 (Mono-c-Si) residential solar systems.

Translucent Solar LLC SK9609MHVC-U-410 delivers 211.3 W/m2 (1.22 percentage points above 19.91% CEC median) and strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 42.25 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with BYD Company Limited BYD410MLK-27 (410.0 W).

Where Does Translucent Solar LLC SK9609MHVC-U-410 Fall Across Listed CEC Models?

Comparison of Translucent Solar LLC SK9609MHVC-U-410 (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Translucent Solar LLC SK9609MHVC-U-410 (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTranslucent Solar : 410.0 W

What Dataset Percentiles Define Translucent Solar LLC SK9609MHVC-U-410?

Relative ranking of Translucent Solar LLC SK9609MHVC-U-410 across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency.

Translucent Solar LLC SK9609MHVC-U-410 Engineering BenchmarksPercentile comparison of Translucent Solar LLC SK9609MHVC-U-410 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.7%Module Efficiency21.13%

What Do the Dataset Ranks Show for Translucent Solar LLC SK9609MHVC-U-410?

Summary of Translucent Solar LLC SK9609MHVC-U-410 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,767

21.13% Aperture Efficiency

Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.12 V at -10 C (575.7 V string) and 42.25 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,686 W PTC; NEC 690.8 OCPD floor is 21.72 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.14 * (1 + (-0.306/100) * (-10 - 25)) = 41.12 V | OCPD = 1.56 * 13.92 = 21.72 A

Inputs from CEC Modules.csv for Translucent Solar LLC SK9609MHVC-U-410: Voc=37.14 V, beta_Voc=-0.306%/C, Isc=13.92 A, STC=410.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (575.7 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for Translucent Solar LLC SK9609MHVC-U-410?

Complete CEC test sheet for Translucent Solar LLC SK9609MHVC-U-410 including Isc (13.92 A), Voc (37.14 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Translucent Solar LLC SK9609MHVC-U-410.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 384.3 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.14 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.92 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.62 V / 13.39 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.306 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.13% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Translucent Solar LLC SK9609MHVC-U-410 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Translucent Solar LLC SK9609MHVC-U-410.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 313 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 418 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 522 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Translucent Solar LLC Series?

Related Translucent Solar LLC power steps and black/silver trims consolidated into this Translucent Solar LLC SK9609MHVC-U-410 series guide.

Sibling CEC listings grouped into the Translucent Solar LLC SK9609MHVC-U-410 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Translucent Solar LLC SK9609MHVC-U-400 400.0 W 374.7 W 36.98 V 30.42 V 20.62%
Translucent Solar LLC SK9609MHVC-U-405 405.0 W 379.5 W 37.06 V 30.52 V 20.88%
Translucent Solar LLC SK9609MHVC-U-410 410.0 W 384.3 W 37.14 V 30.62 V 21.13%
Translucent Solar LLC SK9609MHVC-U-415 415.0 W 389.1 W 37.31 V 30.79 V 21.39%

How Many Translucent Solar LLC SK9609MHVC-U-410 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Translucent Solar LLC SK9609MHVC-U-410 (37.14 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.14V and beta_Voc=-0.306%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.25 V 14 panels 591.5 V 23 panels
-10 C (14 F) 41.12 V 14 panels 575.7 V 24 panels
0 C (32 F) 39.98 V 15 panels 599.7 V 25 panels
25 C (77 F STC) 37.14 V 16 panels 594.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Translucent Solar LLC SK9609MHVC-U-410?

Four comparable CEC modules such as BYD Company Limited BYD410MLK-27 (410.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD410MLK-27
BYD Company Limited
410.0 W Tie (0 W) 37.14 V 21.13% 92.7%
CSI Solar Co Ltd CS6R-410MS-HL {Wht}
CSI Solar Co Ltd
410.0 W Tie (0 W) 37.2 V 21.03% 94.2%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
Dehui Solar Power (Vietnam) CoLtd DH-M154W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Translucent Solar LLC SK9609MHVC-U-410?

Evaluate Translucent Solar LLC SK9609MHVC-U-410 (410.0 W STC, 37.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Translucent Solar LLC SK9609MHVC-U-410 reaches 42.25 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Translucent Solar LLC SK9609MHVC-U-410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Translucent Solar LLC SK9609MHVC-U-410 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare BYD Company Limited BYD410MLK-27.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Translucent Solar LLC SK9609MHVC-U-410 by Translucent Solar LLC grounded in CEC test data and NEC 690.7/690.8 limits.

How many Translucent Solar LLC SK9609MHVC-U-410 panels fit on a 600 V winter solar string?

At -10 C (14 F), Translucent Solar LLC SK9609MHVC-U-410 cold Voc rises from 37.14 V to 41.12 V (beta_Voc -0.306%/C), capping a 600 V string at 14 panels (575.7 V).

How much roof area does an 8 kW array of Translucent Solar LLC SK9609MHVC-U-410 need?

An 8 kW DC system uses 20 Translucent Solar LLC SK9609MHVC-U-410 modules (8,200 W STC / 7,686 W PTC), covering roughly 418 sq ft and saving ~$2,052/yr at 18.54 c/kWh.

How does Translucent Solar LLC SK9609MHVC-U-410 compare against BYD Company Limited BYD410MLK-27?

Translucent Solar LLC SK9609MHVC-U-410 outputs 410.0 W STC (37.14 V Voc, rank #8,539 of 21,677), while BYD Company Limited BYD410MLK-27 delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.