TIDESOLAR PHILIPPINES CORPORATION TDM966-710G is a 710.0 W STC (669.7 W PTC) Mono-c-Si solar module ranking #135 of 21,677 CEC listings (top 0.8%; higher than 99.2% of peers). It delivers 22.83% efficiency, 48.77 V Voc at 25 C, and 52.78 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 710.0 W
- PTC Wattage
- 669.7 W
- Voc @ 25C
- 48.77 V
- Efficiency
- 22.83%
How Does TIDESOLAR PHILIPPINES CORPORATION TDM966-710G Compare Against Peer CEC Listings?
How TIDESOLAR PHILIPPINES CORPORATION TIDESOLAR PHILIPPINES CORPORATION TDM966-710G handles rooftop heat (669.7 W PTC), 8 kW sizing, and cold winter string voltage.
TIDESOLAR PHILIPPINES CORPORATION builds the TIDESOLAR PHILIPPINES CORPORATION TDM966-710G (Mono-c-Si) as a large-format commercial and ground-mount module delivering 228.3 W/m2 (2.92 percentage points above 19.91% CEC median). Compared against New East Solar Energy (Cambodia) CoLtd NESE710-66THB-G12 (710.0 W), this model holds strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677). Higher 48.77 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 28.83 A overcurrent floor served by a 30 A breaker.
Where Does TIDESOLAR PHILIPPINES CORPORATION TDM966-710G Fall Across Listed CEC Models?
Where TIDESOLAR PHILIPPINES CORPORATION TDM966-710G (710.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define TIDESOLAR PHILIPPINES CORPORATION TDM966-710G?
Percentile placement of TIDESOLAR PHILIPPINES CORPORATION TDM966-710G across power density (228.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for TIDESOLAR PHILIPPINES CORPORATION TDM966-710G?
Four critical engineering numbers homeowners and solar installers check first when reviewing TIDESOLAR PHILIPPINES CORPORATION TDM966-710G specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Top 0.8% STC Output
710.0 W STC (+325.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.83% Aperture Efficiency
Power density 228.3 W/m2 (2.92 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.78 V at -10 C (580.6 V string) and 53.93 V at -20 C (11 max).
12 Panels = 8,520 W STC
Occupies 37.3 m2 (402 sq ft) producing 8,036 W PTC; NEC 690.8 OCPD floor is 28.83 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.77 * (1 + (-0.235/100) * (-10 - 25)) = 52.78 V | OCPD = 1.56 * 18.48 = 28.83 A
Inputs from CEC Modules.csv for TIDESOLAR PHILIPPINES CORPORATION TDM966-710G: Voc=48.77 V, beta_Voc=-0.235%/C, Isc=18.48 A, STC=710.0 W, Area=3.11 m2.
Result: 11 panels max on 600 V (580.6 V); 12 panels for 8 kW (402 sq ft).
What Are the Published CEC Specifications for TIDESOLAR PHILIPPINES CORPORATION TDM966-710G?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for TIDESOLAR PHILIPPINES CORPORATION TDM966-710G.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 710.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 669.7 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.77 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.48 V / 17.54 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.83% (3.11 m2) | Array roof footprint density |
| Cell Count & Technology | 22 cells (Mono-c-Si) | Monofacial backsheet |
How Many TIDESOLAR PHILIPPINES CORPORATION TDM966-710G Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using TIDESOLAR PHILIPPINES CORPORATION TDM966-710G (710.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.39 kW | 301 sq ft | $1,599 | $2,704 |
| 8 kW Class | 12 | 8.52 kW | 402 sq ft | $2,132 | $3,606 |
| 10 kW Class | 15 | 10.65 kW | 502 sq ft | $2,666 | $4,507 |
Which Sibling Wattage & Trim Variants Belong to This TIDESOLAR PHILIPPINES CORPORATION Series?
All closely matched TIDESOLAR PHILIPPINES CORPORATION wattages and cosmetic trims sharing the TIDESOLAR PHILIPPINES CORPORATION TDM966-710G architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| TIDESOLAR PHILIPPINES CORPORATION TDM966-700G | 700.0 W | 660.0 W | 48.37 V | 40.15 V | 22.51% |
| TIDESOLAR PHILIPPINES CORPORATION TDM966-705G | 705.0 W | 664.8 W | 48.57 V | 40.31 V | 22.67% |
| TIDESOLAR PHILIPPINES CORPORATION TDM966-710G | 710.0 W | 669.7 W | 48.77 V | 40.48 V | 22.83% |
| TIDESOLAR PHILIPPINES CORPORATION TDM966-715G | 715.0 W | 674.5 W | 48.97 V | 40.65 V | 22.99% |
| TIDESOLAR PHILIPPINES CORPORATION TDM966-720G | 720.0 W | 679.3 W | 49.17 V | 40.81 V | 23.15% |
How Many TIDESOLAR PHILIPPINES CORPORATION TDM966-710G Modules Fit in a Cold-Weather String?
Maximum series module counts for TIDESOLAR PHILIPPINES CORPORATION TDM966-710G from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.93 V | 11 panels | 593.2 V | 18 panels |
| -10 C (14 F) | 52.78 V | 11 panels | 580.6 V | 18 panels |
| 0 C (32 F) | 51.64 V | 11 panels | 568.0 V | 19 panels |
| 25 C (77 F STC) | 48.77 V | 12 panels | 585.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to TIDESOLAR PHILIPPINES CORPORATION TDM966-710G?
Alternative CEC solar modules from competing brands near TIDESOLAR PHILIPPINES CORPORATION TDM966-710G (710.0 W), including New East Solar Energy (Cambodia) CoLtd NESE710-66THB-G12.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| New East Solar Energy (Cambodia) CoLtd NESE710-66THB-G12 New East Solar Energy (Cambodia) CoLtd |
710.0 W | Tie (0 W) | 48.7 V | 23.05% | 95.1% |
| Solarspace Technology Co Ltd SS9-66HD-710N Solarspace Technology Co Ltd |
710.0 W | Tie (0 W) | 48.6 V | 23.05% | 94.7% |
| ELITE Solar ET-N866TBH710GB ELITE Solar |
710.0 W | Tie (0 W) | 48.96 V | 22.83% | 95.0% |
| ELITE Solar ET-N866TBH710GL ELITE Solar |
710.0 W | Tie (0 W) | 48.96 V | 22.83% | 95.0% |
What Are the Design Limits and Best-Fit Uses for TIDESOLAR PHILIPPINES CORPORATION TDM966-710G?
Evaluate TIDESOLAR PHILIPPINES CORPORATION TDM966-710G (710.0 W STC, 48.77 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), TIDESOLAR PHILIPPINES CORPORATION TDM966-710G reaches 53.93 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 12 panels for an 8 kW build require 402 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of TIDESOLAR PHILIPPINES CORPORATION TDM966-710G carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
TIDESOLAR PHILIPPINES CORPORATION TDM966-710G 8 kW Residential Fit
Needs 12 modules (402 sq ft) with a 30 A string OCPD, offsetting ~$2,132/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare New East Solar Energy (Cambodia) CoLtd NESE710-66THB-G12.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 669.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for TIDESOLAR PHILIPPINES CORPORATION TDM966-710G by TIDESOLAR PHILIPPINES CORPORATION grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for TIDESOLAR PHILIPPINES CORPORATION TDM966-710G?
Multiplying TIDESOLAR PHILIPPINES CORPORATION TDM966-710G's 18.48 A short-circuit current by 1.56 equals 28.83 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can TIDESOLAR PHILIPPINES CORPORATION TDM966-710G pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.78 V cold Voc at 14 F and handles 18.48 A Isc; string inverters cap TIDESOLAR PHILIPPINES CORPORATION TDM966-710G at 11 panels on 600 V.
Is TIDESOLAR PHILIPPINES CORPORATION TDM966-710G eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of TIDESOLAR PHILIPPINES CORPORATION TDM966-710G rely on utility bill offset (~$2,132/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)