Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 is a 455.0 W STC (422.4 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.03% efficiency, 41.5 V Voc at 25 C, and 45.92 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 422.4 W
- Voc @ 25C
- 41.5 V
- Efficiency
- 21.03%
How Does Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 Compare Against Peer CEC Listings?
Engineering position of Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 (455.0 W STC) vs. ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS across 5,889 CEC Mono-c-Si solar modules.
Ranking #5,417 across 21,677 CEC solar panels (top 26.2%; higher than 73.8% of peers), Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 operates as a modern high-density residential and light-commercial module sitting 45.0 W above the 410.0 W Mono-c-Si median. Mid-range 41.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677), 18 panels occupy 419 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 Fall Across Listed CEC Models?
Plots Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455?
Benchmarks Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 on STC wattage, thermal PTC/STC retention, and 21.03 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 by Suzhou Talesun Solar Technologies Co Ltd.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.92 V at -10 C (597.0 V string) and 47.18 V at -20 C (12 max).
18 Panels = 8,190 W STC
Occupies 39.0 m2 (419 sq ft) producing 7,603 W PTC; NEC 690.8 OCPD floor is 21.75 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.5 * (1 + (-0.304/100) * (-10 - 25)) = 45.92 V | OCPD = 1.56 * 13.94 = 21.75 A
Inputs from CEC Modules.csv for Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455: Voc=41.5 V, beta_Voc=-0.304%/C, Isc=13.94 A, STC=455.0 W, Area=2.164 m2.
Result: 13 panels max on 600 V (597.0 V); 18 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455?
Laboratory test ratings recorded for Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 422.4 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.94 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.87 V / 13.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.304 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (2.164 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (419 sq ft at 8 kW), and estimated Year-1 electric bill offset for Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 326 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 419 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 512 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Suzhou Talesun Solar Technologies Co Ltd Series?
Sibling wattage bins and frame colors grouped with Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 under Suzhou Talesun Solar Technologies Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-450 | 450.0 W | 417.7 W | 41.33 V | 34.7 V | 20.79% |
| Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 | 455.0 W | 422.4 W | 41.5 V | 34.87 V | 21.03% |
| Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-460 | 460.0 W | 427.2 W | 41.67 V | 35.04 V | 21.26% |
How Many Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 (beta_Voc -0.304%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.18 V | 12 panels | 566.2 V | 21 panels |
| -10 C (14 F) | 45.92 V | 13 panels | 597.0 V | 21 panels |
| 0 C (32 F) | 44.65 V | 13 panels | 580.4 V | 22 panels |
| 25 C (77 F STC) | 41.5 V | 14 panels | 581.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455?
Closest cross-brand CEC competitors to Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 matched near 455.0 W STC and 41.5 V Voc, led by ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
455.0 W | Tie (0 W) | 41.5 V | 21.26% | 92.7% |
| Aptos Solar Technology LLC DNA-120-BF10-455W Aptos Solar Technology LLC |
455.0 W | Tie (0 W) | 41.51 V | 21.26% | 92.7% |
| Dehui Solar Power (Vietnam) CoLtd DH-M160T 455W Dehui Solar Power (Vietnam) CoLtd |
455.0 W | Tie (0 W) | 41.51 V | 21.26% | 92.7% |
| Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos1 Aptos Solar Technology LLC |
455.0 W | Tie (0 W) | 41.65 V | 21.26% | 94.4% |
What Are the Design Limits and Best-Fit Uses for Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455?
Evaluate Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 (455.0 W STC, 41.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 reaches 47.18 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 8 kW Residential Fit
Needs 18 modules (419 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 422.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 by Suzhou Talesun Solar Technologies Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 panels fit on a 600 V winter solar string?
At -10 C (14 F), Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 cold Voc rises from 41.5 V to 45.92 V (beta_Voc -0.304%/C), capping a 600 V string at 13 panels (597.0 V).
How much roof area does an 8 kW array of Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 need?
An 8 kW DC system uses 18 Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 modules (8,190 W STC / 7,603 W PTC), covering roughly 419 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 compare against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS?
Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455 outputs 455.0 W STC (41.5 V Voc, rank #5,417 of 21,677), while ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS delivers 455.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)