Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 is a 540.0 W STC (503.6 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 20.84% efficiency, 49.6 V Voc at 25 C, and 54.44 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 540.0 W
- PTC Wattage
- 503.6 W
- Voc @ 25C
- 49.6 V
- Efficiency
- 20.84%
How Does Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 Compare Against Peer CEC Listings?
How Suzhou Talesun Solar Technologies Co Ltd Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 handles rooftop heat (503.6 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 exhibits 13.86 A short-circuit current, requiring a 21.62 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #3,265 of 21,677 (130.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.9 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.6 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 Fall Across Listed CEC Models?
Where Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 (540.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540?
Percentile placement of Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 across power density (208.4 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540?
Four critical engineering numbers homeowners and solar installers check first when reviewing Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 specifications.
Top 16.3% STC Output
540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.84% Aperture Efficiency
Power density 208.4 W/m2 (0.93 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.44 V at -10 C (598.8 V string) and 55.83 V at -20 C (10 max).
15 Panels = 8,100 W STC
Occupies 38.9 m2 (418 sq ft) producing 7,554 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.6 * (1 + (-0.279/100) * (-10 - 25)) = 54.44 V | OCPD = 1.56 * 13.86 = 21.62 A
Inputs from CEC Modules.csv for Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540: Voc=49.6 V, beta_Voc=-0.279%/C, Isc=13.86 A, STC=540.0 W, Area=2.591 m2.
Result: 11 panels max on 600 V (598.8 V); 15 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 503.6 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.64 V / 12.97 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.84% (2.591 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 (540.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.48 kW | 335 sq ft | $1,622 | $2,742 |
| 8 kW Class | 15 | 8.1 kW | 418 sq ft | $2,027 | $3,428 |
| 10 kW Class | 19 | 10.26 kW | 530 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Suzhou Talesun Solar Technologies Co Ltd Series?
All closely matched Suzhou Talesun Solar Technologies Co Ltd wattages and cosmetic trims sharing the Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-530 | 530.0 W | 494.0 W | 49.32 V | 41.32 V | 20.46% |
| Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-535 | 535.0 W | 498.8 W | 49.46 V | 41.48 V | 20.65% |
| Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 | 540.0 W | 503.6 W | 49.6 V | 41.64 V | 20.84% |
| Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-545 | 545.0 W | 508.4 W | 49.76 V | 41.8 V | 21.03% |
How Many Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 Modules Fit in a Cold-Weather String?
Maximum series module counts for Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.83 V | 10 panels | 558.3 V | 17 panels |
| -10 C (14 F) | 54.44 V | 11 panels | 598.8 V | 18 panels |
| 0 C (32 F) | 53.06 V | 11 panels | 583.7 V | 18 panels |
| 25 C (77 F STC) | 49.6 V | 12 panels | 595.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540?
Alternative CEC solar modules from competing brands near Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 (540.0 W), including AMPS Solar AMPS-540P-72BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AMPS Solar AMPS-540P-72BB AMPS Solar |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 94.3% |
| AXITEC AC-540MH/144V AXITEC |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 93.6% |
| ELITE Solar ET-M772BH540WB ELITE Solar |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 93.6% |
| ELITE Solar ET-M772BH540WW ELITE Solar |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 93.6% |
What Are the Design Limits and Best-Fit Uses for Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540?
Evaluate Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 (540.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 reaches 55.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 418 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 8 kW Residential Fit
Needs 15 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-540P-72BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 503.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 by Suzhou Talesun Solar Technologies Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 PTC wattage (503.6 W) lower than STC (540.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 503.6 W PTC (93.3% retention) across Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540's 2.591 m2 aperture.
Who should skip Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 panels (418 sq ft) leave unusable roof gaps vs. AMPS Solar AMPS-540P-72BB.
What is the 1,000 V commercial string limit for Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540?
On 1,000 V commercial inverters at -10 C (54.44 V cold Voc), Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540 fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)