Skip to main content
WireAndSun
Calculators
CEC PV Module

SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M — CEC Solar Module Specifications

Manufacturer: SUNPLUS OPTIMUM LIMITED Registry: CEC Verified Engineering Specification

SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M is a 555.0 W STC (515.4 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 22.38% efficiency, 50.5 V Voc at 25 C, and 55.52 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
555.0 W
PTC Wattage
515.4 W
Voc @ 25C
50.5 V
Efficiency
22.38%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M (Mono-c-Si) residential solar systems.

Homeowners evaluating SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M need 11 panels for 6 kW or 15 panels (400 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.284%/C) pushes open-circuit voltage to 55.52 V at 14 F and 56.95 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M Fall Across Listed CEC Models?

Comparison of SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M (555.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M (555.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSUNPLUS OPTIMUM LI: 555.0 W

What Dataset Percentiles Define SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Relative ranking of SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M across nameplate watts, 92.9% PTC thermal ratio, and module aperture efficiency.

SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M Engineering BenchmarksPercentile comparison of SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage555.0 WPTC/STC Retention92.9%Module Efficiency22.38%

What Do the Dataset Ranks Show for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Summary of SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,550 / 21,677

Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,267

22.38% Aperture Efficiency

Power density 223.8 W/m2 (2.47 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.52 V at -10 C (555.2 V string) and 56.95 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,325 W STC

Occupies 37.2 m2 (400 sq ft) producing 7,731 W PTC; NEC 690.8 OCPD floor is 21.67 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.5 * (1 + (-0.284/100) * (-10 - 25)) = 55.52 V | OCPD = 1.56 * 13.89 = 21.67 A

Inputs from CEC Modules.csv for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M: Voc=50.5 V, beta_Voc=-0.284%/C, Isc=13.89 A, STC=555.0 W, Area=2.48 m2.

Result: 10 panels max on 600 V (555.2 V); 15 panels for 8 kW (400 sq ft).

What Are the Published CEC Specifications for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Complete CEC test sheet for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M including Isc (13.89 A), Voc (50.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 555.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 515.4 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.89 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.4 V / 13.08 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.284 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.38% (2.48 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.11 kW 294 sq ft $1,529 $2,586
8 kW Class 15 8.32 kW 400 sq ft $2,082 $3,521
10 kW Class 19 10.54 kW 507 sq ft $2,638 $4,461

Which Sibling Wattage & Trim Variants Belong to This SUNPLUS OPTIMUM LIMITED Series?

Related SUNPLUS OPTIMUM LIMITED power steps and black/silver trims consolidated into this SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M series guide.

Sibling CEC listings grouped into the SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SUNPLUS OPTIMUM LIMITED SR4-72HBD-550M 550.0 W 510.6 W 50.3 V 42.3 V 22.18%
SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M 555.0 W 515.4 W 50.5 V 42.4 V 22.38%
SUNPLUS OPTIMUM LIMITED SR4-72HBD-560M 560.0 W 520.2 W 50.7 V 42.6 V 22.58%

How Many SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M (50.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=50.5V and beta_Voc=-0.284%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.95 V 10 panels 569.5 V 17 panels
-10 C (14 F) 55.52 V 10 panels 555.2 V 18 panels
0 C (32 F) 54.09 V 11 panels 595.0 V 18 panels
25 C (77 F STC) 50.5 V 11 panels 555.5 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Four comparable CEC modules such as Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555 (555.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555
Chint New Energy Technology Co Ltd
555.0 W Tie (0 W) 50.5 V 22.38% 92.9%
ASTORIOS Holding Inc ASTR144BDG-555W-US
ASTORIOS Holding Inc
555.0 W Tie (0 W) 50.4 V 21.51% 93.7%
AXITEC AC-555MBT/144US
AXITEC
555.0 W Tie (0 W) 50.4 V 21.51% 93.6%
Energy America LLC EA-ZLK7-SHDB144-555/M
Energy America LLC
555.0 W Tie (0 W) 50.4 V 21.51% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Evaluate SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M (555.0 W STC, 50.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M reaches 56.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 400 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M 8 kW Residential Fit

Needs 15 modules (400 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 515.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M by SUNPLUS OPTIMUM LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

Why is SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M PTC wattage (515.4 W) lower than STC (555.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 515.4 W PTC (92.9% retention) across SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M's 2.48 m2 aperture.

Who should skip SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M panels (400 sq ft) leave unusable roof gaps vs. Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555.

What is the 1,000 V commercial string limit for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

On 1,000 V commercial inverters at -10 C (55.52 V cold Voc), SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.