SUNPLUS OPTIMUM INC SR4-54HTB-435M is a 435.0 W STC (405.6 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 23.02% efficiency, 39.2 V Voc at 25 C, and 42.9 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 435.0 W
- PTC Wattage
- 405.6 W
- Voc @ 25C
- 39.2 V
- Efficiency
- 23.02%
How Does SUNPLUS OPTIMUM INC SR4-54HTB-435M Compare Against Peer CEC Listings?
How SUNPLUS OPTIMUM INC SUNPLUS OPTIMUM INC SR4-54HTB-435M handles rooftop heat (405.6 W PTC), 8 kW sizing, and cold winter string voltage.
SUNPLUS OPTIMUM INC builds the SUNPLUS OPTIMUM INC SR4-54HTB-435M (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 230.2 W/m2 (3.11 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435 (435.0 W), this model holds strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Lower 39.2 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.75 A overcurrent floor served by a 25 A breaker.
Where Does SUNPLUS OPTIMUM INC SR4-54HTB-435M Fall Across Listed CEC Models?
Where SUNPLUS OPTIMUM INC SR4-54HTB-435M (435.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define SUNPLUS OPTIMUM INC SR4-54HTB-435M?
Percentile placement of SUNPLUS OPTIMUM INC SR4-54HTB-435M across power density (230.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for SUNPLUS OPTIMUM INC SR4-54HTB-435M?
Four critical engineering numbers homeowners and solar installers check first when reviewing SUNPLUS OPTIMUM INC SR4-54HTB-435M specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Top 33.5% STC Output
435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.02% Aperture Efficiency
Power density 230.2 W/m2 (3.11 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.9 V at -10 C (557.7 V string) and 43.96 V at -20 C (13 max).
19 Panels = 8,265 W STC
Occupies 35.9 m2 (387 sq ft) producing 7,706 W PTC; NEC 690.8 OCPD floor is 21.75 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.2 * (1 + (-0.27/100) * (-10 - 25)) = 42.9 V | OCPD = 1.56 * 13.94 = 21.75 A
Inputs from CEC Modules.csv for SUNPLUS OPTIMUM INC SR4-54HTB-435M: Voc=39.2 V, beta_Voc=-0.27%/C, Isc=13.94 A, STC=435.0 W, Area=1.89 m2.
Result: 13 panels max on 600 V (557.7 V); 19 panels for 8 kW (387 sq ft).
What Are the Published CEC Specifications for SUNPLUS OPTIMUM INC SR4-54HTB-435M?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SUNPLUS OPTIMUM INC SR4-54HTB-435M.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 405.6 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.94 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.2 V / 13.51 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.27 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.02% (1.89 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many SUNPLUS OPTIMUM INC SR4-54HTB-435M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SUNPLUS OPTIMUM INC SR4-54HTB-435M (435.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.09 kW | 285 sq ft | $1,524 | $2,577 |
| 8 kW Class | 19 | 8.27 kW | 387 sq ft | $2,070 | $3,500 |
| 10 kW Class | 23 | 10.01 kW | 468 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This SUNPLUS OPTIMUM INC Series?
All closely matched SUNPLUS OPTIMUM INC wattages and cosmetic trims sharing the SUNPLUS OPTIMUM INC SR4-54HTB-435M architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SUNPLUS OPTIMUM INC SR4-54HTB-425M | 425.0 W | 396.0 W | 38.8 V | 31.8 V | 22.49% |
| SUNPLUS OPTIMUM INC SR4-54HTB-430M | 430.0 W | 400.8 W | 39.0 V | 32.0 V | 22.75% |
| SUNPLUS OPTIMUM INC SR4-54HTB-435M | 435.0 W | 405.6 W | 39.2 V | 32.2 V | 23.02% |
| SUNPLUS OPTIMUM INC SR4-54HTB-440M | 440.0 W | 410.4 W | 39.4 V | 32.4 V | 23.28% |
| SUNPLUS OPTIMUM INC SR4-54HTB-445M | 445.0 W | 415.2 W | 39.6 V | 32.6 V | 23.54% |
How Many SUNPLUS OPTIMUM INC SR4-54HTB-435M Modules Fit in a Cold-Weather String?
Maximum series module counts for SUNPLUS OPTIMUM INC SR4-54HTB-435M from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.96 V | 13 panels | 571.5 V | 22 panels |
| -10 C (14 F) | 42.9 V | 13 panels | 557.7 V | 23 panels |
| 0 C (32 F) | 41.85 V | 14 panels | 585.9 V | 23 panels |
| 25 C (77 F STC) | 39.2 V | 15 panels | 588.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to SUNPLUS OPTIMUM INC SR4-54HTB-435M?
Alternative CEC solar modules from competing brands near SUNPLUS OPTIMUM INC SR4-54HTB-435M (435.0 W), including Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435 Elin Energy (Sirius PV) |
435.0 W | Tie (0 W) | 39.1 V | 22.42% | 95.0% |
| Elin Energy (Sirius PV) ELNSM54M-HC-N-435 Elin Energy (Sirius PV) |
435.0 W | Tie (0 W) | 39.1 V | 22.42% | 95.0% |
| Auxin Solar AXN10M435B Auxin Solar |
435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.2% |
| Auxin Solar AXN10M435W Auxin Solar |
435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.3% |
What Are the Design Limits and Best-Fit Uses for SUNPLUS OPTIMUM INC SR4-54HTB-435M?
Evaluate SUNPLUS OPTIMUM INC SR4-54HTB-435M (435.0 W STC, 39.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SUNPLUS OPTIMUM INC SR4-54HTB-435M reaches 43.96 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 387 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (387 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SUNPLUS OPTIMUM INC SR4-54HTB-435M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SUNPLUS OPTIMUM INC SR4-54HTB-435M 8 kW Residential Fit
Needs 19 modules (387 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 405.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SUNPLUS OPTIMUM INC SR4-54HTB-435M by SUNPLUS OPTIMUM INC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for SUNPLUS OPTIMUM INC SR4-54HTB-435M?
Multiplying SUNPLUS OPTIMUM INC SR4-54HTB-435M's 13.94 A short-circuit current by 1.56 equals 21.75 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can SUNPLUS OPTIMUM INC SR4-54HTB-435M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.9 V cold Voc at 14 F and handles 13.94 A Isc; string inverters cap SUNPLUS OPTIMUM INC SR4-54HTB-435M at 13 panels on 600 V.
Is SUNPLUS OPTIMUM INC SR4-54HTB-435M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SUNPLUS OPTIMUM INC SR4-54HTB-435M rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)