Sunpal Power Co Ltd SP535M-72HB is a 535.0 W STC (502.8 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 20.74% efficiency, 49.48 V Voc at 25 C, and 53.98 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 535.0 W
- PTC Wattage
- 502.8 W
- Voc @ 25C
- 49.48 V
- Efficiency
- 20.74%
How Does Sunpal Power Co Ltd SP535M-72HB Compare Against Peer CEC Listings?
Solar engineering breakdown for Sunpal Power Co Ltd SP535M-72HB: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Sunpal Power Co Ltd and peers, Sunpal Power Co Ltd SP535M-72HB stands 125.0 W above the 410.0 W Mono-c-Si median and strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677). Sizing 6 kW (12 panels) to 10 kW (19 panels) yields $1,607-$2,543/yr in baseline US bill offset. Higher 49.48 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Sunpal Power Co Ltd SP535M-72HB Fall Across Listed CEC Models?
Distribution marker showing Sunpal Power Co Ltd SP535M-72HB (535.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Sunpal Power Co Ltd SP535M-72HB?
Dataset percentiles tracking Sunpal Power Co Ltd SP535M-72HB power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Sunpal Power Co Ltd SP535M-72HB?
Benchmark highlights for Sunpal Power Co Ltd SP535M-72HB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 17.5% STC Output
535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.74% Aperture Efficiency
Power density 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.98 V at -10 C (593.8 V string) and 55.27 V at -20 C (10 max).
15 Panels = 8,025 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,542 W PTC; NEC 690.8 OCPD floor is 21.45 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.48 * (1 + (-0.26/100) * (-10 - 25)) = 53.98 V | OCPD = 1.56 * 13.75 = 21.45 A
Inputs from CEC Modules.csv for Sunpal Power Co Ltd SP535M-72HB: Voc=49.48 V, beta_Voc=-0.26%/C, Isc=13.75 A, STC=535.0 W, Area=2.58 m2.
Result: 11 panels max on 600 V (593.8 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Sunpal Power Co Ltd SP535M-72HB?
Official CEC datasheet figures for Sunpal Power Co Ltd SP535M-72HB (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 535.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 502.8 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.48 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.77 V / 13.13 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.26 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.74% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Sunpal Power Co Ltd SP535M-72HB Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Sunpal Power Co Ltd SP535M-72HB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.42 kW | 333 sq ft | $1,607 | $2,717 |
| 8 kW Class | 15 | 8.03 kW | 417 sq ft | $2,010 | $3,398 |
| 10 kW Class | 19 | 10.16 kW | 528 sq ft | $2,543 | $4,300 |
Which Sibling Wattage & Trim Variants Belong to This Sunpal Power Co Ltd Series?
Consolidated Sunpal Power Co Ltd wattage variants sharing the Sunpal Power Co Ltd SP535M-72HB mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Sunpal Power Co Ltd SP525M-72HB | 525.0 W | 493.1 W | 49.28 V | 40.59 V | 20.35% |
| Sunpal Power Co Ltd SP530M-72HB | 530.0 W | 497.9 W | 49.38 V | 40.68 V | 20.54% |
| Sunpal Power Co Ltd SP535M-72HB | 535.0 W | 502.8 W | 49.48 V | 40.77 V | 20.74% |
| Sunpal Power Co Ltd SP540M-72HB | 540.0 W | 507.6 W | 49.58 V | 40.86 V | 20.93% |
| Sunpal Power Co Ltd SP545M-72HB | 545.0 W | 512.4 W | 49.68 V | 40.95 V | 21.12% |
How Many Sunpal Power Co Ltd SP535M-72HB Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Sunpal Power Co Ltd SP535M-72HB (53.98 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.27 V | 10 panels | 552.7 V | 18 panels |
| -10 C (14 F) | 53.98 V | 11 panels | 593.8 V | 18 panels |
| 0 C (32 F) | 52.7 V | 11 panels | 579.7 V | 18 panels |
| 25 C (77 F STC) | 49.48 V | 12 panels | 593.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Sunpal Power Co Ltd SP535M-72HB?
Competing CEC solar panels closest to Sunpal Power Co Ltd SP535M-72HB in nameplate wattage and Voc, starting with Heliene 144HC-535 M10 SL.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Heliene 144HC-535 M10 SL Heliene |
535.0 W | Tie (0 W) | 49.47 V | 21.49% | 93.5% |
| Chint New Energy Technology Co Ltd CHSM72M-HC-535 Chint New Energy Technology Co Ltd |
535.0 W | Tie (0 W) | 49.5 V | 21.57% | 92.6% |
| ELITE Solar ET-M772BH535GL ELITE Solar |
535.0 W | Tie (0 W) | 49.45 V | 20.9% | 94.1% |
| Hyperion Solar HY-WH144P8-535 Hyperion Solar |
535.0 W | Tie (0 W) | 49.45 V | 20.74% | 92.8% |
What Are the Design Limits and Best-Fit Uses for Sunpal Power Co Ltd SP535M-72HB?
Evaluate Sunpal Power Co Ltd SP535M-72HB (535.0 W STC, 49.48 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Sunpal Power Co Ltd SP535M-72HB reaches 55.27 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Sunpal Power Co Ltd SP535M-72HB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Sunpal Power Co Ltd SP535M-72HB 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Heliene 144HC-535 M10 SL.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 502.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Sunpal Power Co Ltd SP535M-72HB by Sunpal Power Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Sunpal Power Co Ltd SP535M-72HB?
Multiplying Sunpal Power Co Ltd SP535M-72HB's 13.75 A short-circuit current by 1.56 equals 21.45 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Sunpal Power Co Ltd SP535M-72HB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.98 V cold Voc at 14 F and handles 13.75 A Isc; string inverters cap Sunpal Power Co Ltd SP535M-72HB at 11 panels on 600 V.
Is Sunpal Power Co Ltd SP535M-72HB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sunpal Power Co Ltd SP535M-72HB rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)