Manufacturer: Sonali Energees Registry: CEC Verified Engineering Specification

Sonali Energees SS 315 is a 315.0 W STC (288.4 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.43% efficiency, 45.72 V Voc at 25 C, and 51.02 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
288.4 W
Voc @ 25C
45.72 V
Efficiency
16.43%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sonali Energees SS 315 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Sonali Energees SS 315 (Multi-c-Si) residential solar systems.

Homeowners evaluating Sonali Energees SS 315 need 20 panels for 6 kW or 26 panels (536 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (536 sq ft). Under NEC 690.7(A), beta_Voc (-0.331%/C) pushes open-circuit voltage to 51.02 V at 14 F and 52.53 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Sonali Energees SS 315 Fall Across Listed CEC Models?

Comparison of Sonali Energees SS 315 (315.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sonali Energees SS 315 (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSonali Energees SS: 315.0 W

What Dataset Percentiles Define Sonali Energees SS 315?

Relative ranking of Sonali Energees SS 315 across nameplate watts, 91.6% PTC thermal ratio, and module aperture efficiency.

Sonali Energees SS 315 Engineering BenchmarksPercentile comparison of Sonali Energees SS 315 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention91.6%Module Efficiency16.43%

What Do the Dataset Ranks Show for Sonali Energees SS 315?

Summary of Sonali Energees SS 315 output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,493

16.43% Aperture Efficiency

Power density 164.3 W/m2 (3.48 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.02 V at -10 C (561.2 V string) and 52.53 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 49.8 m2 (536 sq ft) producing 7,498 W PTC; NEC 690.8 OCPD floor is 13.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.72 * (1 + (-0.331/100) * (-10 - 25)) = 51.02 V | OCPD = 1.56 * 8.59 = 13.4 A

Inputs from CEC Modules.csv for Sonali Energees SS 315: Voc=45.72 V, beta_Voc=-0.331%/C, Isc=8.59 A, STC=315.0 W, Area=1.917 m2.

Result: 11 panels max on 600 V (561.2 V); 26 panels for 8 kW (536 sq ft).

What Are the Published CEC Specifications for Sonali Energees SS 315?

Complete CEC test sheet for Sonali Energees SS 315 including Isc (8.59 A), Voc (45.72 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Sonali Energees SS 315.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 288.4 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.72 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.1 V / 8.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.331 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.43% (1.917 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Sonali Energees SS 315 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Sonali Energees SS 315.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 413 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 536 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 660 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Sonali Energees Series?

Related Sonali Energees power steps and black/silver trims consolidated into this Sonali Energees SS 315 series guide.

Sibling CEC listings grouped into the Sonali Energees SS 315 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Sonali Energees SS 300 300.0 W 274.4 W 44.64 V 37.58 V 15.65%
Sonali Energees SS 310 310.0 W 283.7 W 45.36 V 37.9 V 16.17%
Sonali Energees SS 315 315.0 W 288.4 W 45.72 V 38.1 V 16.43%
Sonali Energees SS 320 320.0 W 293.1 W 46.08 V 38.3 V 16.69%

How Many Sonali Energees SS 315 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Sonali Energees SS 315 (45.72 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.72V and beta_Voc=-0.331%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.53 V 11 panels 577.8 V 19 panels
-10 C (14 F) 51.02 V 11 panels 561.2 V 19 panels
0 C (32 F) 49.5 V 12 panels 594.0 V 20 panels
25 C (77 F STC) 45.72 V 13 panels 594.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Sonali Energees SS 315?

Four comparable CEC modules such as Centrosolar America EP72 315BW (315.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America EP72 315BW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
Centrosolar America EP72 315SW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
GCL System Integration Technology Co Ltd GCL-P6/72315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 45.6 V 16.23% 90.5%
Boviet Solar Technology Co Ltd BVM6612M-315
Boviet Solar Technology Co Ltd
315.0 W Tie (0 W) 46.1 V 16.23% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sonali Energees SS 315?

Evaluate Sonali Energees SS 315 (315.0 W STC, 45.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sonali Energees SS 315 reaches 52.53 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 536 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (536 sq ft).
  • 2026 tax credit baseline: cash residential installs of Sonali Energees SS 315 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sonali Energees SS 315 8 kW Residential Fit

Needs 26 modules (536 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EP72 315BW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sonali Energees SS 315 by Sonali Energees grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Sonali Energees SS 315 PTC wattage (288.4 W) lower than STC (315.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 288.4 W PTC (91.6% retention) across Sonali Energees SS 315's 1.917 m2 aperture.

Who should skip Sonali Energees SS 315 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 Sonali Energees SS 315 panels (536 sq ft) leave unusable roof gaps vs. Centrosolar America EP72 315BW.

What is the 1,000 V commercial string limit for Sonali Energees SS 315?

On 1,000 V commercial inverters at -10 C (51.02 V cold Voc), Sonali Energees SS 315 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Sonali Energees SS 315.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.