Solartech Energy ASC-6P-72-285 — CEC Solar Module Specifications

Manufacturer: Solartech Energy Registry: CEC Verified Engineering Specification

Solartech Energy ASC-6P-72-285 is a 285.0 W STC (256.4 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.66% efficiency, 44.32 V Voc at 25 C, and 49.58 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
256.4 W
Voc @ 25C
44.32 V
Efficiency
14.66%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solartech Energy ASC-6P-72-285 Compare Against Peer CEC Listings?

How Solartech Energy Solartech Energy ASC-6P-72-285 handles rooftop heat (256.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Solartech Energy ASC-6P-72-285 exhibits 8.41 A short-circuit current, requiring a 13.12 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,598 of 21,677 (6.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 56.4 m2 for an 8 kW system (36 panels for 10 kW). Mid-range 44.32 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Solartech Energy ASC-6P-72-285 Fall Across Listed CEC Models?

Where Solartech Energy ASC-6P-72-285 (285.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solartech Energy ASC-6P-72-285 (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolartech Energy A: 285.0 W

What Dataset Percentiles Define Solartech Energy ASC-6P-72-285?

Percentile placement of Solartech Energy ASC-6P-72-285 across power density (146.6 W/m2), thermal retention, and nameplate STC wattage.

Solartech Energy ASC-6P-72-285 Engineering BenchmarksPercentile comparison of Solartech Energy ASC-6P-72-285 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention90.0%Module Efficiency14.66%

What Do the Dataset Ranks Show for Solartech Energy ASC-6P-72-285?

Four critical engineering numbers homeowners and solar installers check first when reviewing Solartech Energy ASC-6P-72-285 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,225

14.66% Aperture Efficiency

Power density 146.6 W/m2 (5.25 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.58 V at -10 C (595.0 V string) and 51.08 V at -20 C (11 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 56.4 m2 (607 sq ft) producing 7,436 W PTC; NEC 690.8 OCPD floor is 13.12 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.32 * (1 + (-0.339/100) * (-10 - 25)) = 49.58 V | OCPD = 1.56 * 8.41 = 13.12 A

Inputs from CEC Modules.csv for Solartech Energy ASC-6P-72-285: Voc=44.32 V, beta_Voc=-0.339%/C, Isc=8.41 A, STC=285.0 W, Area=1.944 m2.

Result: 12 panels max on 600 V (595.0 V); 29 panels for 8 kW (607 sq ft).

What Are the Published CEC Specifications for Solartech Energy ASC-6P-72-285?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solartech Energy ASC-6P-72-285.

Official California Energy Commission (NREL SAM) test parameters for Solartech Energy ASC-6P-72-285.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 256.4 W (90.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.41 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.02 V / 7.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.339 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.66% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Solartech Energy ASC-6P-72-285 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solartech Energy ASC-6P-72-285 (285.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 460 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 607 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 753 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Solartech Energy Series?

All closely matched Solartech Energy wattages and cosmetic trims sharing the Solartech Energy ASC-6P-72-285 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Solartech Energy ASC-6P-72-285 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solartech Energy ASC-6P-72-275 275.0 W 243.2 W 44.0 V 35.7 V 14.14%
Solartech Energy ASC-6P-72-280 280.0 W 251.8 W 44.15 V 35.78 V 14.4%
Solartech Energy ASC-6P-72-285 285.0 W 256.4 W 44.32 V 36.02 V 14.66%
Solartech Energy ASC-6P-72-290 290.0 W 261.0 W 44.46 V 36.16 V 14.92%
Solartech Energy ASC-6P-72-295 295.0 W 265.7 W 44.68 V 36.38 V 15.17%

How Many Solartech Energy ASC-6P-72-285 Modules Fit in a Cold-Weather String?

Maximum series module counts for Solartech Energy ASC-6P-72-285 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.32V and beta_Voc=-0.339%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.08 V 11 panels 561.9 V 19 panels
-10 C (14 F) 49.58 V 12 panels 595.0 V 20 panels
0 C (32 F) 48.08 V 12 panels 577.0 V 20 panels
25 C (77 F STC) 44.32 V 13 panels 576.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Solartech Energy ASC-6P-72-285?

Alternative CEC solar modules from competing brands near Solartech Energy ASC-6P-72-285 (285.0 W), including Centrosolar America DP72 285.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP72 285
Centrosolar America
285.0 W Tie (0 W) 44.32 V 14.66% 88.5%
BYD Company Limited BYD 285P6C-36
BYD Company Limited
285.0 W Tie (0 W) 44.3 V 14.69% 91.0%
CSI Solar Co Ltd CS6X-285P
CSI Solar Co Ltd
285.0 W Tie (0 W) 44.3 V 15.39% 91.8%
Advance Power API-M285
Advance Power
285.0 W Tie (0 W) 44.21 V 14.61% 89.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solartech Energy ASC-6P-72-285?

Evaluate Solartech Energy ASC-6P-72-285 (285.0 W STC, 44.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solartech Energy ASC-6P-72-285 reaches 51.08 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 607 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (607 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solartech Energy ASC-6P-72-285 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solartech Energy ASC-6P-72-285 8 kW Residential Fit

Needs 29 modules (607 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 285.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solartech Energy ASC-6P-72-285 by Solartech Energy grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Solartech Energy ASC-6P-72-285 PTC wattage (256.4 W) lower than STC (285.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 256.4 W PTC (90.0% retention) across Solartech Energy ASC-6P-72-285's 1.944 m2 aperture.

Who should skip Solartech Energy ASC-6P-72-285 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 Solartech Energy ASC-6P-72-285 panels (607 sq ft) leave unusable roof gaps vs. Centrosolar America DP72 285.

What is the 1,000 V commercial string limit for Solartech Energy ASC-6P-72-285?

On 1,000 V commercial inverters at -10 C (49.58 V cold Voc), Solartech Energy ASC-6P-72-285 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solartech Energy ASC-6P-72-285.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.