Manufacturer: Solarspace Technology Co Ltd Registry: CEC Verified Engineering Specification

Solarspace Technology Co Ltd SS8-54HSB-395M is a 395.0 W STC (377.0 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 29.92% efficiency, 36.98 V Voc at 25 C, and 40.06 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
377.0 W
Voc @ 25C
36.98 V
Efficiency
29.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solarspace Technology Co Ltd SS8-54HSB-395M Compare Against Peer CEC Listings?

Solar engineering breakdown for Solarspace Technology Co Ltd SS8-54HSB-395M: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Solarspace Technology Co Ltd and peers, Solarspace Technology Co Ltd SS8-54HSB-395M stands 15.0 W below the 410.0 W Mono-c-Si median and strong 95.4% PTC-to-STC heat retention (#141 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,582-$2,570/yr in baseline US bill offset. Lower 36.98 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Solarspace Technology Co Ltd SS8-54HSB-395M Fall Across Listed CEC Models?

Distribution marker showing Solarspace Technology Co Ltd SS8-54HSB-395M (395.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solarspace Technology Co Ltd SS8-54HSB-395M (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolarspace Technol: 395.0 W

What Dataset Percentiles Define Solarspace Technology Co Ltd SS8-54HSB-395M?

Dataset percentiles tracking Solarspace Technology Co Ltd SS8-54HSB-395M power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Solarspace Technology Co Ltd SS8-54HSB-395M Engineering BenchmarksPercentile comparison of Solarspace Technology Co Ltd SS8-54HSB-395M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention95.4%Module Efficiency29.92%

What Do the Dataset Ranks Show for Solarspace Technology Co Ltd SS8-54HSB-395M?

Benchmark highlights for Solarspace Technology Co Ltd SS8-54HSB-395M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18

29.92% Aperture Efficiency

Power density 299.2 W/m2 (10.01 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.06 V at -10 C (560.8 V string) and 40.94 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 27.7 m2 (298 sq ft) producing 7,917 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.98 * (1 + (-0.238/100) * (-10 - 25)) = 40.06 V | OCPD = 1.56 * 13.7 = 21.37 A

Inputs from CEC Modules.csv for Solarspace Technology Co Ltd SS8-54HSB-395M: Voc=36.98 V, beta_Voc=-0.238%/C, Isc=13.7 A, STC=395.0 W, Area=1.32 m2.

Result: 14 panels max on 600 V (560.8 V); 21 panels for 8 kW (298 sq ft).

What Are the Published CEC Specifications for Solarspace Technology Co Ltd SS8-54HSB-395M?

Official CEC datasheet figures for Solarspace Technology Co Ltd SS8-54HSB-395M (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Solarspace Technology Co Ltd SS8-54HSB-395M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 377.0 W (95.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.98 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.7 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.84 V / 12.81 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.238 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 29.92% (1.32 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Solarspace Technology Co Ltd SS8-54HSB-395M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Solarspace Technology Co Ltd SS8-54HSB-395M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 227 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 298 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 369 sq ft $2,570 $4,347

How Many Solarspace Technology Co Ltd SS8-54HSB-395M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Solarspace Technology Co Ltd SS8-54HSB-395M (40.06 V at 14 F).

Computed from Voc=36.98V and beta_Voc=-0.238%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 40.94 V 14 panels 573.2 V 24 panels
-10 C (14 F) 40.06 V 14 panels 560.8 V 24 panels
0 C (32 F) 39.18 V 15 panels 587.7 V 25 panels
25 C (77 F STC) 36.98 V 16 panels 591.7 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Solarspace Technology Co Ltd SS8-54HSB-395M?

Competing CEC solar panels closest to Solarspace Technology Co Ltd SS8-54HSB-395M in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-108-MF10-395W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-108-MF10-395W
Aptos Solar Technology LLC
395.0 W Tie (0 W) 36.98 V 20.26% 93.7%
CertainTeed CTM10395HC11-06
CertainTeed
395.0 W Tie (0 W) 36.98 V 20.26% 93.7%
Changzhou EGing Photovoltaic Technology Co Ltd EG-395M54-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
395.0 W Tie (0 W) 37.0 V 20.26% 93.7%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
395.0 W Tie (0 W) 36.94 V 20.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solarspace Technology Co Ltd SS8-54HSB-395M?

Evaluate Solarspace Technology Co Ltd SS8-54HSB-395M (395.0 W STC, 36.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solarspace Technology Co Ltd SS8-54HSB-395M reaches 40.94 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 298 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (298 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Solarspace Technology Co Ltd SS8-54HSB-395M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solarspace Technology Co Ltd SS8-54HSB-395M 8 kW Residential Fit

Needs 21 modules (298 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-395W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 377.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solarspace Technology Co Ltd SS8-54HSB-395M by Solarspace Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Solarspace Technology Co Ltd SS8-54HSB-395M?

Multiplying Solarspace Technology Co Ltd SS8-54HSB-395M's 13.7 A short-circuit current by 1.56 equals 21.37 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Solarspace Technology Co Ltd SS8-54HSB-395M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.06 V cold Voc at 14 F and handles 13.7 A Isc; string inverters cap Solarspace Technology Co Ltd SS8-54HSB-395M at 14 panels on 600 V.

Is Solarspace Technology Co Ltd SS8-54HSB-395M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solarspace Technology Co Ltd SS8-54HSB-395M rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.