Manufacturer: Solar Power (SPI) Registry: CEC Verified Engineering Specification

Solar Power (SPI) ES310PBFW is a 310.0 W STC (281.4 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 16.07% efficiency, 46.1 V Voc at 25 C, and 51.33 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
281.4 W
Voc @ 25C
46.1 V
Efficiency
16.07%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solar Power (SPI) ES310PBFW Compare Against Peer CEC Listings?

Engineering position of Solar Power (SPI) ES310PBFW (310.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612P-310 across 1,407 CEC Multi-c-Si solar modules.

Built with 72 Multi-c-Si cells, Solar Power (SPI) ES310PBFW pairs typical 90.8% PTC-to-STC thermal output (281.4 W real-world rating) with 46.1 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,316 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6612P-310 offers a 310.0 W alternative.

Where Does Solar Power (SPI) ES310PBFW Fall Across Listed CEC Models?

Plots Solar Power (SPI) ES310PBFW at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solar Power (SPI) ES310PBFW (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolar Power (SPI) : 310.0 W

What Dataset Percentiles Define Solar Power (SPI) ES310PBFW?

Benchmarks Solar Power (SPI) ES310PBFW on STC wattage, thermal PTC/STC retention, and 16.07 aperture conversion efficiency against CEC peers.

Solar Power (SPI) ES310PBFW Engineering BenchmarksPercentile comparison of Solar Power (SPI) ES310PBFW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention90.8%Module Efficiency16.07%

What Do the Dataset Ranks Show for Solar Power (SPI) ES310PBFW?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Solar Power (SPI) ES310PBFW by Solar Power (SPI).

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,013

16.07% Aperture Efficiency

Power density 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.33 V at -10 C (564.6 V string) and 52.82 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 50.2 m2 (540 sq ft) producing 7,316 W PTC; NEC 690.8 OCPD floor is 13.49 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.1 * (1 + (-0.324/100) * (-10 - 25)) = 51.33 V | OCPD = 1.56 * 8.65 = 13.49 A

Inputs from CEC Modules.csv for Solar Power (SPI) ES310PBFW: Voc=46.1 V, beta_Voc=-0.324%/C, Isc=8.65 A, STC=310.0 W, Area=1.929 m2.

Result: 11 panels max on 600 V (564.6 V); 26 panels for 8 kW (540 sq ft).

What Are the Published CEC Specifications for Solar Power (SPI) ES310PBFW?

Laboratory test ratings recorded for Solar Power (SPI) ES310PBFW (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Solar Power (SPI) ES310PBFW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 281.4 W (90.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.65 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.8 V / 8.21 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.07% (1.929 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Solar Power (SPI) ES310PBFW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (540 sq ft at 8 kW), and estimated Year-1 electric bill offset for Solar Power (SPI) ES310PBFW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 415 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 540 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 685 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Solar Power (SPI) Series?

Sibling wattage bins and frame colors grouped with Solar Power (SPI) ES310PBFW under Solar Power (SPI) to prevent duplicate spec pages.

Sibling CEC listings grouped into the Solar Power (SPI) ES310PBFW wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solar Power (SPI) ES300PBFW 300.0 W 272.1 W 45.4 V 37.1 V 15.56%
Solar Power (SPI) ES305PBFW 305.0 W 276.8 W 45.8 V 37.4 V 15.81%
Solar Power (SPI) ES310PBFW 310.0 W 281.4 W 46.1 V 37.8 V 16.07%
Solar Power (SPI) ES315PBFW 315.0 W 286.1 W 46.4 V 38.2 V 16.33%

How Many Solar Power (SPI) ES310PBFW Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Solar Power (SPI) ES310PBFW (beta_Voc -0.324%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=46.1V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.82 V 11 panels 581.0 V 18 panels
-10 C (14 F) 51.33 V 11 panels 564.6 V 19 panels
0 C (32 F) 49.83 V 12 panels 598.0 V 20 panels
25 C (77 F STC) 46.1 V 13 panels 599.3 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Solar Power (SPI) ES310PBFW?

Closest cross-brand CEC competitors to Solar Power (SPI) ES310PBFW matched near 310.0 W STC and 46.1 V Voc, led by Boviet Solar Technology Co Ltd BVM6612P-310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612P-310
Boviet Solar Technology Co Ltd
310.0 W Tie (0 W) 45.8 V 15.98% 90.3%
Centrosolar America CP72 310-C1
Centrosolar America
310.0 W Tie (0 W) 45.8 V 15.98% 90.3%
BYD Company Limited BYD 310P6C-36
BYD Company Limited
310.0 W Tie (0 W) 45.79 V 15.98% 91.2%
BYD Company Limited BYD310P6K-36
BYD Company Limited
310.0 W Tie (0 W) 45.79 V 15.98% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solar Power (SPI) ES310PBFW?

Evaluate Solar Power (SPI) ES310PBFW (310.0 W STC, 46.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solar Power (SPI) ES310PBFW reaches 52.82 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 540 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (540 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solar Power (SPI) ES310PBFW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solar Power (SPI) ES310PBFW 8 kW Residential Fit

Needs 26 modules (540 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solar Power (SPI) ES310PBFW by Solar Power (SPI) grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Solar Power (SPI) ES310PBFW?

Multiplying Solar Power (SPI) ES310PBFW's 8.65 A short-circuit current by 1.56 equals 13.49 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Solar Power (SPI) ES310PBFW pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.33 V cold Voc at 14 F and handles 8.65 A Isc; string inverters cap Solar Power (SPI) ES310PBFW at 11 panels on 600 V.

Is Solar Power (SPI) ES310PBFW eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solar Power (SPI) ES310PBFW rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.