Shinsung E&G Co Ltd SSV320-120MH is a 320.0 W STC (297.1 W PTC) Mono-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 19.05% efficiency, 40.2 V Voc at 25 C, and 43.96 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 320.0 W
- PTC Wattage
- 297.1 W
- Voc @ 25C
- 40.2 V
- Efficiency
- 19.05%
How Does Shinsung E&G Co Ltd SSV320-120MH Compare Against Peer CEC Listings?
Engineering position of Shinsung E&G Co Ltd SSV320-120MH (320.0 W STC) vs. Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W across 5,889 CEC Mono-c-Si solar modules.
Ranking #14,944 across 21,677 CEC solar panels (below all-CEC median; higher than 29.0% of peers), Shinsung E&G Co Ltd SSV320-120MH operates as a compact residential or specialty off-grid module sitting 90.0 W below the 410.0 W Mono-c-Si median. Mid-range 40.2 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677), 25 panels occupy 452 sq ft and offset roughly $2,002/yr at average US rates (or $3,386/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Shinsung E&G Co Ltd SSV320-120MH Fall Across Listed CEC Models?
Plots Shinsung E&G Co Ltd SSV320-120MH at 320.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Shinsung E&G Co Ltd SSV320-120MH?
Benchmarks Shinsung E&G Co Ltd SSV320-120MH on STC wattage, thermal PTC/STC retention, and 19.05 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Shinsung E&G Co Ltd SSV320-120MH?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Shinsung E&G Co Ltd SSV320-120MH by Shinsung E&G Co Ltd.
320.0 W STC · Higher Than 29.0%
320.0 W STC (-65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.05% Aperture Efficiency
Power density 190.5 W/m2 (0.86 percentage points below 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.96 V at -10 C (571.5 V string) and 45.03 V at -20 C (13 max).
25 Panels = 8,000 W STC
Occupies 42.0 m2 (452 sq ft) producing 7,428 W PTC; NEC 690.8 OCPD floor is 15.87 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.2 * (1 + (-0.267/100) * (-10 - 25)) = 43.96 V | OCPD = 1.56 * 10.17 = 15.87 A
Inputs from CEC Modules.csv for Shinsung E&G Co Ltd SSV320-120MH: Voc=40.2 V, beta_Voc=-0.267%/C, Isc=10.17 A, STC=320.0 W, Area=1.68 m2.
Result: 13 panels max on 600 V (571.5 V); 25 panels for 8 kW (452 sq ft).
What Are the Published CEC Specifications for Shinsung E&G Co Ltd SSV320-120MH?
Laboratory test ratings recorded for Shinsung E&G Co Ltd SSV320-120MH (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 320.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 297.1 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.17 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.3 V / 9.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.267 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.05% (1.68 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Shinsung E&G Co Ltd SSV320-120MH Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (452 sq ft at 8 kW), and estimated Year-1 electric bill offset for Shinsung E&G Co Ltd SSV320-120MH.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.08 kW | 344 sq ft | $1,522 | $2,573 |
| 8 kW Class | 25 | 8.0 kW | 452 sq ft | $2,002 | $3,386 |
| 10 kW Class | 32 | 10.24 kW | 579 sq ft | $2,563 | $4,334 |
How Many Shinsung E&G Co Ltd SSV320-120MH Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Shinsung E&G Co Ltd SSV320-120MH (beta_Voc -0.267%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.03 V | 13 panels | 585.4 V | 22 panels |
| -10 C (14 F) | 43.96 V | 13 panels | 571.5 V | 22 panels |
| 0 C (32 F) | 42.88 V | 13 panels | 557.4 V | 23 panels |
| 25 C (77 F STC) | 40.2 V | 14 panels | 562.8 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Shinsung E&G Co Ltd SSV320-120MH?
Closest cross-brand CEC competitors to Shinsung E&G Co Ltd SSV320-120MH matched near 320.0 W STC and 40.2 V Voc, led by Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W Dehui Solar Power (Vietnam) CoLtd |
320.0 W | Tie (0 W) | 40.2 V | 19.88% | 92.9% |
| GCL System Integration Technology Co Ltd GCL-M6/60320 GCL System Integration Technology Co Ltd |
320.0 W | Tie (0 W) | 40.3 V | 19.63% | 91.3% |
| CSI Solar Co Ltd CS3K-320MS CSI Solar Co Ltd |
320.0 W | Tie (0 W) | 40.1 V | 20.0% | 93.2% |
| Aptos Solar Technology LLC DNA-120-MF23-320W {Blk} Aptos Solar Technology LLC |
320.0 W | Tie (0 W) | 39.92 V | 18.96% | 90.7% |
What Are the Design Limits and Best-Fit Uses for Shinsung E&G Co Ltd SSV320-120MH?
Evaluate Shinsung E&G Co Ltd SSV320-120MH (320.0 W STC, 40.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Shinsung E&G Co Ltd SSV320-120MH reaches 45.03 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 452 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (452 sq ft).
- 2026 tax credit baseline: cash residential installs of Shinsung E&G Co Ltd SSV320-120MH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Shinsung E&G Co Ltd SSV320-120MH 8 kW Residential Fit
Needs 25 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 297.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Shinsung E&G Co Ltd SSV320-120MH by Shinsung E&G Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Shinsung E&G Co Ltd SSV320-120MH panels fit on a 600 V winter solar string?
At -10 C (14 F), Shinsung E&G Co Ltd SSV320-120MH cold Voc rises from 40.2 V to 43.96 V (beta_Voc -0.267%/C), capping a 600 V string at 13 panels (571.5 V).
How much roof area does an 8 kW array of Shinsung E&G Co Ltd SSV320-120MH need?
An 8 kW DC system uses 25 Shinsung E&G Co Ltd SSV320-120MH modules (8,000 W STC / 7,428 W PTC), covering roughly 452 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does Shinsung E&G Co Ltd SSV320-120MH compare against Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W?
Shinsung E&G Co Ltd SSV320-120MH outputs 320.0 W STC (40.2 V Voc, rank #14,944 of 21,677), while Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W delivers 320.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)