Skip to main content
WireAndSun
Calculators
CEC PV Module

SEG Solar Inc SEG-E01A-365 — CEC Solar Module Specifications

Manufacturer: SEG Solar Inc Registry: CEC Verified Engineering Specification

SEG Solar Inc SEG-E01A-365 is a 365.0 W STC (332.4 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 17.89% efficiency, 43.9 V Voc at 25 C, and 48.51 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
332.4 W
Voc @ 25C
43.9 V
Efficiency
17.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SEG Solar Inc SEG-E01A-365 Compare Against Peer CEC Listings?

Solar engineering breakdown for SEG Solar Inc SEG-E01A-365: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from SEG Solar Inc and peers, SEG Solar Inc SEG-E01A-365 stands 45.0 W below the 410.0 W Mono-c-Si median and typical 91.1% PTC-to-STC thermal output (332.4 W real-world rating). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,554-$2,558/yr in baseline US bill offset. Mid-range 43.9 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does SEG Solar Inc SEG-E01A-365 Fall Across Listed CEC Models?

Distribution marker showing SEG Solar Inc SEG-E01A-365 (365.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SEG Solar Inc SEG-E01A-365 (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSEG Solar Inc SEG-: 365.0 W

What Dataset Percentiles Define SEG Solar Inc SEG-E01A-365?

Dataset percentiles tracking SEG Solar Inc SEG-E01A-365 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

SEG Solar Inc SEG-E01A-365 Engineering BenchmarksPercentile comparison of SEG Solar Inc SEG-E01A-365 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention91.1%Module Efficiency17.89%

What Do the Dataset Ranks Show for SEG Solar Inc SEG-E01A-365?

Benchmark highlights for SEG Solar Inc SEG-E01A-365 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,240

17.89% Aperture Efficiency

Power density 178.9 W/m2 (2.02 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.51 V at -10 C (582.1 V string) and 49.83 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 44.9 m2 (483 sq ft) producing 7,313 W PTC; NEC 690.8 OCPD floor is 16.47 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.9 * (1 + (-0.3/100) * (-10 - 25)) = 48.51 V | OCPD = 1.56 * 10.56 = 16.47 A

Inputs from CEC Modules.csv for SEG Solar Inc SEG-E01A-365: Voc=43.9 V, beta_Voc=-0.3%/C, Isc=10.56 A, STC=365.0 W, Area=2.04 m2.

Result: 12 panels max on 600 V (582.1 V); 22 panels for 8 kW (483 sq ft).

What Are the Published CEC Specifications for SEG Solar Inc SEG-E01A-365?

Official CEC datasheet figures for SEG Solar Inc SEG-E01A-365 (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for SEG Solar Inc SEG-E01A-365.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 332.4 W (91.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.8 V / 10.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.89% (2.04 m2) Array roof footprint density
Cell Count & Technology 408 cells (Mono-c-Si) Monofacial backsheet

How Many SEG Solar Inc SEG-E01A-365 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many SEG Solar Inc SEG-E01A-365 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 373 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 483 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 615 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This SEG Solar Inc Series?

Consolidated SEG Solar Inc wattage variants sharing the SEG Solar Inc SEG-E01A-365 mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the SEG Solar Inc SEG-E01A-365 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SEG Solar Inc SEG-E01A-360 360.0 W 327.7 W 43.7 V 35.6 V 17.65%
SEG Solar Inc SEG-E01A-365 365.0 W 332.4 W 43.9 V 35.8 V 17.89%
SEG Solar Inc SEG-E01A-370 370.0 W 337.1 W 44.1 V 36.0 V 18.14%

How Many SEG Solar Inc SEG-E01A-365 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on SEG Solar Inc SEG-E01A-365 (48.51 V at 14 F).

Computed from Voc=43.9V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.83 V 12 panels 598.0 V 20 panels
-10 C (14 F) 48.51 V 12 panels 582.1 V 20 panels
0 C (32 F) 47.19 V 12 panels 566.3 V 21 panels
25 C (77 F STC) 43.9 V 13 panels 570.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to SEG Solar Inc SEG-E01A-365?

Competing CEC solar panels closest to SEG Solar Inc SEG-E01A-365 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6XH-360M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6XH-360M
CSI Solar Co Ltd
360.0 W -5.0 W 45.0 V 19.46% 92.8%
EMMVEE Photovoltaic Power Private Limited E370M72-B
EMMVEE Photovoltaic Power Private Limited
370.0 W +5.0 W 45.25 V 18.56% 91.4%
Caterpillar Inc PVC365MP03HA
Caterpillar Inc
365.0 W Tie (0 W) 41.0 V 20.62% 93.5%
Bluesun Solar CoLtd BSM365M-60HPH
Bluesun Solar CoLtd
365.0 W Tie (0 W) 40.9 V 20.05% 92.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SEG Solar Inc SEG-E01A-365?

Evaluate SEG Solar Inc SEG-E01A-365 (365.0 W STC, 43.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SEG Solar Inc SEG-E01A-365 reaches 49.83 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 483 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (483 sq ft).
  • 2026 tax credit baseline: cash residential installs of SEG Solar Inc SEG-E01A-365 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SEG Solar Inc SEG-E01A-365 8 kW Residential Fit

Needs 22 modules (483 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS6XH-360M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SEG Solar Inc SEG-E01A-365 by SEG Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SEG Solar Inc SEG-E01A-365?

Multiplying SEG Solar Inc SEG-E01A-365's 10.56 A short-circuit current by 1.56 equals 16.47 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can SEG Solar Inc SEG-E01A-365 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 48.51 V cold Voc at 14 F and handles 10.56 A Isc; string inverters cap SEG Solar Inc SEG-E01A-365 at 12 panels on 600 V.

Is SEG Solar Inc SEG-E01A-365 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SEG Solar Inc SEG-E01A-365 rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.