Manufacturer: SEG Solar Inc Registry: CEC Verified Engineering Specification

SEG Solar Inc SEG-BPB-265BB is a 265.0 W STC (241.7 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.16% efficiency, 37.5 V Voc at 25 C, and 41.53 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
241.7 W
Voc @ 25C
37.5 V
Efficiency
16.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SEG Solar Inc SEG-BPB-265BB Compare Against Peer CEC Listings?

Solar engineering breakdown for SEG Solar Inc SEG-BPB-265BB: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from SEG Solar Inc and peers, SEG Solar Inc SEG-BPB-265BB stands 13.8 W below the 278.8 W Multi-c-Si median and typical 91.2% PTC-to-STC thermal output (241.7 W real-world rating). Sizing 6 kW (23 panels) to 10 kW (38 panels) yields $1,524-$2,520/yr in baseline US bill offset. Lower 37.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does SEG Solar Inc SEG-BPB-265BB Fall Across Listed CEC Models?

Distribution marker showing SEG Solar Inc SEG-BPB-265BB (265.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SEG Solar Inc SEG-BPB-265BB (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSEG Solar Inc SEG-: 265.0 W

What Dataset Percentiles Define SEG Solar Inc SEG-BPB-265BB?

Dataset percentiles tracking SEG Solar Inc SEG-BPB-265BB power output, thermal retention ratio, and aperture efficiency against 21,677 models.

SEG Solar Inc SEG-BPB-265BB Engineering BenchmarksPercentile comparison of SEG Solar Inc SEG-BPB-265BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention91.2%Module Efficiency16.16%

What Do the Dataset Ranks Show for SEG Solar Inc SEG-BPB-265BB?

Benchmark highlights for SEG Solar Inc SEG-BPB-265BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,903

16.16% Aperture Efficiency

Power density 161.6 W/m2 (3.75 percentage points below 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.53 V at -10 C (581.4 V string) and 42.68 V at -20 C (14 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 50.8 m2 (547 sq ft) producing 7,493 W PTC; NEC 690.8 OCPD floor is 14.09 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.5 * (1 + (-0.307/100) * (-10 - 25)) = 41.53 V | OCPD = 1.56 * 9.03 = 14.09 A

Inputs from CEC Modules.csv for SEG Solar Inc SEG-BPB-265BB: Voc=37.5 V, beta_Voc=-0.307%/C, Isc=9.03 A, STC=265.0 W, Area=1.64 m2.

Result: 14 panels max on 600 V (581.4 V); 31 panels for 8 kW (547 sq ft).

What Are the Published CEC Specifications for SEG Solar Inc SEG-BPB-265BB?

Official CEC datasheet figures for SEG Solar Inc SEG-BPB-265BB (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for SEG Solar Inc SEG-BPB-265BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 241.7 W (91.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.03 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.3 V / 8.47 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.16% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many SEG Solar Inc SEG-BPB-265BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many SEG Solar Inc SEG-BPB-265BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 406 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 547 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 671 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This SEG Solar Inc Series?

Consolidated SEG Solar Inc wattage variants sharing the SEG Solar Inc SEG-BPB-265BB mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the SEG Solar Inc SEG-BPB-265BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SEG Solar Inc SEG-BPB-255BB 255.0 W 232.3 W 37.0 V 30.8 V 15.55%
SEG Solar Inc SEG-BPB-260BB 260.0 W 237.0 W 37.2 V 31.0 V 15.85%
SEG Solar Inc SEG-BPB-265BB 265.0 W 241.7 W 37.5 V 31.3 V 16.16%
SEG Solar Inc SEG-BPB-270BB 270.0 W 246.4 W 37.7 V 31.5 V 16.46%

How Many SEG Solar Inc SEG-BPB-265BB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on SEG Solar Inc SEG-BPB-265BB (41.53 V at 14 F).

Computed from Voc=37.5V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.68 V 14 panels 597.5 V 23 panels
-10 C (14 F) 41.53 V 14 panels 581.4 V 24 panels
0 C (32 F) 40.38 V 14 panels 565.3 V 24 panels
25 C (77 F STC) 37.5 V 16 panels 600.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to SEG Solar Inc SEG-BPB-265BB?

Competing CEC solar panels closest to SEG Solar Inc SEG-BPB-265BB in nameplate wattage and Voc, starting with Centrosolar America TM6 265xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TM6 265xx
Centrosolar America
265.0 W Tie (0 W) 38.0 V 16.22% 90.9%
Centrosolar America TM6S 265xx
Centrosolar America
265.0 W Tie (0 W) 38.0 V 16.22% 90.9%
GCL System Integration Technology Co Ltd GCL-P6/60265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.29% 90.5%
GCL System Integration Technology Co Ltd GCL-P6/60B265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.26% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SEG Solar Inc SEG-BPB-265BB?

Evaluate SEG Solar Inc SEG-BPB-265BB (265.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SEG Solar Inc SEG-BPB-265BB reaches 42.68 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (547 sq ft).
  • 2026 tax credit baseline: cash residential installs of SEG Solar Inc SEG-BPB-265BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SEG Solar Inc SEG-BPB-265BB 8 kW Residential Fit

Needs 31 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America TM6 265xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 241.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SEG Solar Inc SEG-BPB-265BB by SEG Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SEG Solar Inc SEG-BPB-265BB?

Multiplying SEG Solar Inc SEG-BPB-265BB's 9.03 A short-circuit current by 1.56 equals 14.09 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can SEG Solar Inc SEG-BPB-265BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.53 V cold Voc at 14 F and handles 9.03 A Isc; string inverters cap SEG Solar Inc SEG-BPB-265BB at 14 panels on 600 V.

Is SEG Solar Inc SEG-BPB-265BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SEG Solar Inc SEG-BPB-265BB rely on utility bill offset (~$2,055/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.