Manufacturer: SEG Solar Inc Registry: CEC Verified Engineering Specification

SEG Solar Inc SEG-505-BTB-HV is a 505.0 W STC (482.3 W PTC) Mono-c-Si solar module ranking #4,444 of 21,677 CEC listings (top 20.8%; higher than 79.2% of peers). It delivers 24.05% efficiency, 44.18 V Voc at 25 C, and 47.81 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
505.0 W
PTC Wattage
482.3 W
Voc @ 25C
44.18 V
Efficiency
24.05%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SEG Solar Inc SEG-505-BTB-HV Compare Against Peer CEC Listings?

Solar engineering breakdown for SEG Solar Inc SEG-505-BTB-HV: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from SEG Solar Inc and peers, SEG Solar Inc SEG-505-BTB-HV stands 95.0 W above the 410.0 W Mono-c-Si median and strong 95.5% PTC-to-STC heat retention (#102 of 21,677). Sizing 6 kW (12 panels) to 10 kW (20 panels) yields $1,517-$2,528/yr in baseline US bill offset. Mid-range 44.18 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does SEG Solar Inc SEG-505-BTB-HV Fall Across Listed CEC Models?

Distribution marker showing SEG Solar Inc SEG-505-BTB-HV (505.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SEG Solar Inc SEG-505-BTB-HV (505.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSEG Solar Inc SEG-: 505.0 W

What Dataset Percentiles Define SEG Solar Inc SEG-505-BTB-HV?

Dataset percentiles tracking SEG Solar Inc SEG-505-BTB-HV power output, thermal retention ratio, and aperture efficiency against 21,677 models.

SEG Solar Inc SEG-505-BTB-HV Engineering BenchmarksPercentile comparison of SEG Solar Inc SEG-505-BTB-HV wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage505.0 WPTC/STC Retention95.5%Module Efficiency24.05%

What Do the Dataset Ranks Show for SEG Solar Inc SEG-505-BTB-HV?

Benchmark highlights for SEG Solar Inc SEG-505-BTB-HV covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,444 / 21,677

Top 20.8% STC Output

505.0 W STC (+120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #208

24.05% Aperture Efficiency

Power density 240.5 W/m2 (4.14 percentage points above 19.91% CEC median). PTC/STC ratio: 95.5% (rank #102).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.81 V at -10 C (573.7 V string) and 48.85 V at -20 C (12 max).

8 kW Reference Array

16 Panels = 8,080 W STC

Occupies 33.6 m2 (362 sq ft) producing 7,717 W PTC; NEC 690.8 OCPD floor is 22.01 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.18 * (1 + (-0.235/100) * (-10 - 25)) = 47.81 V | OCPD = 1.56 * 14.11 = 22.01 A

Inputs from CEC Modules.csv for SEG Solar Inc SEG-505-BTB-HV: Voc=44.18 V, beta_Voc=-0.235%/C, Isc=14.11 A, STC=505.0 W, Area=2.1 m2.

Result: 12 panels max on 600 V (573.7 V); 16 panels for 8 kW (362 sq ft).

What Are the Published CEC Specifications for SEG Solar Inc SEG-505-BTB-HV?

Official CEC datasheet figures for SEG Solar Inc SEG-505-BTB-HV (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for SEG Solar Inc SEG-505-BTB-HV.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 505.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 482.3 W (95.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.18 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.11 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.55 V / 13.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.235 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 24.05% (2.1 m2) Array roof footprint density
Cell Count & Technology 20 cells (Mono-c-Si) Bifacial glass-glass

How Many SEG Solar Inc SEG-505-BTB-HV Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many SEG Solar Inc SEG-505-BTB-HV modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.06 kW 271 sq ft $1,517 $2,565
8 kW Class 16 8.08 kW 362 sq ft $2,022 $3,420
10 kW Class 20 10.1 kW 452 sq ft $2,528 $4,275

Which Sibling Wattage & Trim Variants Belong to This SEG Solar Inc Series?

Consolidated SEG Solar Inc wattage variants sharing the SEG Solar Inc SEG-505-BTB-HV mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the SEG Solar Inc SEG-505-BTB-HV wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SEG Solar Inc SEG-500-BTB-HV 500.0 W 477.4 W 44.0 V 37.38 V 23.81%
SEG Solar Inc SEG-505-BTB-HV 505.0 W 482.3 W 44.18 V 37.55 V 24.05%
SEG Solar Inc SEG-510-BTB-HV 510.0 W 487.2 W 44.38 V 37.75 V 24.29%

How Many SEG Solar Inc SEG-505-BTB-HV Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on SEG Solar Inc SEG-505-BTB-HV (47.81 V at 14 F).

Computed from Voc=44.18V and beta_Voc=-0.235%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 48.85 V 12 panels 586.2 V 20 panels
-10 C (14 F) 47.81 V 12 panels 573.7 V 20 panels
0 C (32 F) 46.78 V 12 panels 561.4 V 21 panels
25 C (77 F STC) 44.18 V 13 panels 574.3 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to SEG Solar Inc SEG-505-BTB-HV?

Competing CEC solar panels closest to SEG Solar Inc SEG-505-BTB-HV in nameplate wattage and Voc, starting with Hyperion Solar HY-DH132P8-505.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hyperion Solar HY-DH132P8-505
Hyperion Solar
505.0 W Tie (0 W) 45.72 V 21.31% 93.0%
Hyperion Solar HY-DH132P8-505-B
Hyperion Solar
505.0 W Tie (0 W) 45.72 V 21.31% 93.0%
Hyperion Solar HY-DH132P8-505-T
Hyperion Solar
505.0 W Tie (0 W) 45.72 V 21.31% 93.0%
Aptos Solar Technology LLC DNA-132-BF10-500W
Aptos Solar Technology LLC
500.0 W -5.0 W 45.6 V 21.1% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SEG Solar Inc SEG-505-BTB-HV?

Evaluate SEG Solar Inc SEG-505-BTB-HV (505.0 W STC, 44.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SEG Solar Inc SEG-505-BTB-HV reaches 48.85 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 362 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (362 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SEG Solar Inc SEG-505-BTB-HV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SEG Solar Inc SEG-505-BTB-HV 8 kW Residential Fit

Needs 16 modules (362 sq ft) with a 25 A string OCPD, offsetting ~$2,022/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Hyperion Solar HY-DH132P8-505.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 482.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SEG Solar Inc SEG-505-BTB-HV by SEG Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SEG Solar Inc SEG-505-BTB-HV?

Multiplying SEG Solar Inc SEG-505-BTB-HV's 14.11 A short-circuit current by 1.56 equals 22.01 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can SEG Solar Inc SEG-505-BTB-HV pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 47.81 V cold Voc at 14 F and handles 14.11 A Isc; string inverters cap SEG Solar Inc SEG-505-BTB-HV at 12 panels on 600 V.

Is SEG Solar Inc SEG-505-BTB-HV eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SEG Solar Inc SEG-505-BTB-HV rely on utility bill offset (~$2,022/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.