SEG Solar Inc SEG-435-BMB-HV — CEC Solar Module Specifications

Manufacturer: SEG Solar Inc Registry: CEC Verified Engineering Specification

SEG Solar Inc SEG-435-BMB-HV is a 435.0 W STC (411.3 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.14% efficiency, 41.01 V Voc at 25 C, and 44.45 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
411.3 W
Voc @ 25C
41.01 V
Efficiency
20.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SEG Solar Inc SEG-435-BMB-HV Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SEG Solar Inc SEG-435-BMB-HV (Mono-c-Si) residential solar systems.

Homeowners evaluating SEG Solar Inc SEG-435-BMB-HV need 14 panels for 6 kW or 19 panels (442 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.24%/C) pushes open-circuit voltage to 44.45 V at 14 F and 45.44 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does SEG Solar Inc SEG-435-BMB-HV Fall Across Listed CEC Models?

Comparison of SEG Solar Inc SEG-435-BMB-HV (435.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SEG Solar Inc SEG-435-BMB-HV (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSEG Solar Inc SEG-: 435.0 W

What Dataset Percentiles Define SEG Solar Inc SEG-435-BMB-HV?

Relative ranking of SEG Solar Inc SEG-435-BMB-HV across nameplate watts, 94.6% PTC thermal ratio, and module aperture efficiency.

SEG Solar Inc SEG-435-BMB-HV Engineering BenchmarksPercentile comparison of SEG Solar Inc SEG-435-BMB-HV wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention94.6%Module Efficiency20.14%

What Do the Dataset Ranks Show for SEG Solar Inc SEG-435-BMB-HV?

Summary of SEG Solar Inc SEG-435-BMB-HV output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,983

20.14% Aperture Efficiency

Power density 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.45 V at -10 C (577.9 V string) and 45.44 V at -20 C (13 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 41.0 m2 (442 sq ft) producing 7,815 W PTC; NEC 690.8 OCPD floor is 20.98 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.01 * (1 + (-0.24/100) * (-10 - 25)) = 44.45 V | OCPD = 1.56 * 13.45 = 20.98 A

Inputs from CEC Modules.csv for SEG Solar Inc SEG-435-BMB-HV: Voc=41.01 V, beta_Voc=-0.24%/C, Isc=13.45 A, STC=435.0 W, Area=2.16 m2.

Result: 13 panels max on 600 V (577.9 V); 19 panels for 8 kW (442 sq ft).

What Are the Published CEC Specifications for SEG Solar Inc SEG-435-BMB-HV?

Complete CEC test sheet for SEG Solar Inc SEG-435-BMB-HV including Isc (13.45 A), Voc (41.01 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SEG Solar Inc SEG-435-BMB-HV.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 411.3 W (94.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.01 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.98 V / 12.82 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.24 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.14% (2.16 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many SEG Solar Inc SEG-435-BMB-HV Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SEG Solar Inc SEG-435-BMB-HV.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 326 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 442 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 535 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This SEG Solar Inc Series?

Related SEG Solar Inc power steps and black/silver trims consolidated into this SEG Solar Inc SEG-435-BMB-HV series guide.

Sibling CEC listings grouped into the SEG Solar Inc SEG-435-BMB-HV wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SEG Solar Inc SEG-425-BMB-HV 425.0 W 401.7 W 40.82 V 33.77 V 19.68%
SEG Solar Inc SEG-430-BMB-HV 430.0 W 406.5 W 40.92 V 33.85 V 19.91%
SEG Solar Inc SEG-435-BMB-HV 435.0 W 411.3 W 41.01 V 33.98 V 20.14%
SEG Solar Inc SEG-440-BMB-HV 440.0 W 416.2 W 41.12 V 34.08 V 20.37%
SEG Solar Inc SEG-445-BMB-HV 445.0 W 421.0 W 41.22 V 34.18 V 20.6%

How Many SEG Solar Inc SEG-435-BMB-HV Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SEG Solar Inc SEG-435-BMB-HV (41.01 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.01V and beta_Voc=-0.24%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.44 V 13 panels 590.7 V 22 panels
-10 C (14 F) 44.45 V 13 panels 577.9 V 22 panels
0 C (32 F) 43.47 V 13 panels 565.1 V 23 panels
25 C (77 F STC) 41.01 V 14 panels 574.1 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to SEG Solar Inc SEG-435-BMB-HV?

Four comparable CEC modules such as CertainTeed CTM10435HC11-06 (435.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10435HC11-06
CertainTeed
435.0 W Tie (0 W) 40.95 V 20.14% 93.7%
Boviet Solar Technology Co Ltd BVM7610M-435-H-HC
Boviet Solar Technology Co Ltd
435.0 W Tie (0 W) 41.21 V 20.71% 94.0%
AE Solar GmbH AE435CMD-108BDE
AE Solar GmbH
435.0 W Tie (0 W) 40.1 V 22.31% 94.9%
DE SOLAR(S) PTE LTD DE435-108BG-182S-N/BB
DE SOLAR(S) PTE LTD
435.0 W Tie (0 W) 40.1 V 22.31% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SEG Solar Inc SEG-435-BMB-HV?

Evaluate SEG Solar Inc SEG-435-BMB-HV (435.0 W STC, 41.01 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SEG Solar Inc SEG-435-BMB-HV reaches 45.44 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SEG Solar Inc SEG-435-BMB-HV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SEG Solar Inc SEG-435-BMB-HV 8 kW Residential Fit

Needs 19 modules (442 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CTM10435HC11-06.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 411.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SEG Solar Inc SEG-435-BMB-HV by SEG Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is SEG Solar Inc SEG-435-BMB-HV PTC wattage (411.3 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 411.3 W PTC (94.6% retention) across SEG Solar Inc SEG-435-BMB-HV's 2.16 m2 aperture.

Who should skip SEG Solar Inc SEG-435-BMB-HV on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 SEG Solar Inc SEG-435-BMB-HV panels (442 sq ft) leave unusable roof gaps vs. CertainTeed CTM10435HC11-06.

What is the 1,000 V commercial string limit for SEG Solar Inc SEG-435-BMB-HV?

On 1,000 V commercial inverters at -10 C (44.45 V cold Voc), SEG Solar Inc SEG-435-BMB-HV fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SEG Solar Inc SEG-435-BMB-HV.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.