Skip to main content
WireAndSun
Calculators
CEC PV Module

SEG Solar Inc SEG-410-BMD-TB — CEC Solar Module Specifications

Manufacturer: SEG Solar Inc Registry: CEC Verified Engineering Specification

SEG Solar Inc SEG-410-BMD-TB is a 410.0 W STC (383.9 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 20.92% efficiency, 37.32 V Voc at 25 C, and 40.53 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
383.9 W
Voc @ 25C
37.32 V
Efficiency
20.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SEG Solar Inc SEG-410-BMD-TB Compare Against Peer CEC Listings?

How SEG Solar Inc SEG Solar Inc SEG-410-BMD-TB handles rooftop heat (383.9 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, SEG Solar Inc SEG-410-BMD-TB exhibits 13.8 A short-circuit current, requiring a 21.53 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #8,539 of 21,677 (equal to the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.2 m2 for an 8 kW system (25 panels for 10 kW). Lower 37.32 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does SEG Solar Inc SEG-410-BMD-TB Fall Across Listed CEC Models?

Where SEG Solar Inc SEG-410-BMD-TB (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SEG Solar Inc SEG-410-BMD-TB (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSEG Solar Inc SEG-: 410.0 W

What Dataset Percentiles Define SEG Solar Inc SEG-410-BMD-TB?

Percentile placement of SEG Solar Inc SEG-410-BMD-TB across power density (209.2 W/m2), thermal retention, and nameplate STC wattage.

SEG Solar Inc SEG-410-BMD-TB Engineering BenchmarksPercentile comparison of SEG Solar Inc SEG-410-BMD-TB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.6%Module Efficiency20.92%

What Do the Dataset Ranks Show for SEG Solar Inc SEG-410-BMD-TB?

Four critical engineering numbers homeowners and solar installers check first when reviewing SEG Solar Inc SEG-410-BMD-TB specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,759

20.92% Aperture Efficiency

Power density 209.2 W/m2 (1.01 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.53 V at -10 C (567.4 V string) and 41.45 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 39.2 m2 (422 sq ft) producing 7,678 W PTC; NEC 690.8 OCPD floor is 21.53 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.32 * (1 + (-0.246/100) * (-10 - 25)) = 40.53 V | OCPD = 1.56 * 13.8 = 21.53 A

Inputs from CEC Modules.csv for SEG Solar Inc SEG-410-BMD-TB: Voc=37.32 V, beta_Voc=-0.246%/C, Isc=13.8 A, STC=410.0 W, Area=1.96 m2.

Result: 14 panels max on 600 V (567.4 V); 20 panels for 8 kW (422 sq ft).

What Are the Published CEC Specifications for SEG Solar Inc SEG-410-BMD-TB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SEG Solar Inc SEG-410-BMD-TB.

Official California Energy Commission (NREL SAM) test parameters for SEG Solar Inc SEG-410-BMD-TB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 383.9 W (93.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.8 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.05 V / 13.21 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.246 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.92% (1.96 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many SEG Solar Inc SEG-410-BMD-TB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SEG Solar Inc SEG-410-BMD-TB (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 316 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 422 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 527 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This SEG Solar Inc Series?

All closely matched SEG Solar Inc wattages and cosmetic trims sharing the SEG Solar Inc SEG-410-BMD-TB architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the SEG Solar Inc SEG-410-BMD-TB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SEG Solar Inc SEG-400-BMD-TB 400.0 W 374.3 W 37.12 V 30.81 V 20.41%
SEG Solar Inc SEG-405-BMD-TB 405.0 W 379.1 W 37.22 V 30.93 V 20.66%
SEG Solar Inc SEG-410-BMD-TB 410.0 W 383.9 W 37.32 V 31.05 V 20.92%
SEG Solar Inc SEG-415-BMD-TB 415.0 W 388.7 W 37.42 V 31.17 V 21.17%
SEG Solar Inc SEG-420-BMD-TB 420.0 W 395.3 W 37.52 V 31.28 V 21.43%

How Many SEG Solar Inc SEG-410-BMD-TB Modules Fit in a Cold-Weather String?

Maximum series module counts for SEG Solar Inc SEG-410-BMD-TB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.32V and beta_Voc=-0.246%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.45 V 14 panels 580.3 V 24 panels
-10 C (14 F) 40.53 V 14 panels 567.4 V 24 panels
0 C (32 F) 39.62 V 15 panels 594.3 V 25 panels
25 C (77 F STC) 37.32 V 16 panels 597.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to SEG Solar Inc SEG-410-BMD-TB?

Alternative CEC solar modules from competing brands near SEG Solar Inc SEG-410-BMD-TB (410.0 W), including Aptos Solar Technology LLC DNA-108-MF10-410W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-108-MF10-410W
Aptos Solar Technology LLC
410.0 W Tie (0 W) 37.32 V 21.03% 93.8%
CertainTeed CTM10410HC11-06
CertainTeed
410.0 W Tie (0 W) 37.32 V 21.03% 93.8%
Elin Energy (Sirius PV) ELNSM54M-HC-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.3%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SEG Solar Inc SEG-410-BMD-TB?

Evaluate SEG Solar Inc SEG-410-BMD-TB (410.0 W STC, 37.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SEG Solar Inc SEG-410-BMD-TB reaches 41.45 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 422 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (422 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SEG Solar Inc SEG-410-BMD-TB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SEG Solar Inc SEG-410-BMD-TB 8 kW Residential Fit

Needs 20 modules (422 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-410W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SEG Solar Inc SEG-410-BMD-TB by SEG Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is SEG Solar Inc SEG-410-BMD-TB PTC wattage (383.9 W) lower than STC (410.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 383.9 W PTC (93.6% retention) across SEG Solar Inc SEG-410-BMD-TB's 1.96 m2 aperture.

Who should skip SEG Solar Inc SEG-410-BMD-TB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 SEG Solar Inc SEG-410-BMD-TB panels (422 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-108-MF10-410W.

What is the 1,000 V commercial string limit for SEG Solar Inc SEG-410-BMD-TB?

On 1,000 V commercial inverters at -10 C (40.53 V cold Voc), SEG Solar Inc SEG-410-BMD-TB fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SEG Solar Inc SEG-410-BMD-TB.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.