RSI Holding RSI-6M-260M-60 is a 260.0 W STC (235.6 W PTC) Mono-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.15% efficiency, 37.4 V Voc at 25 C, and 41.77 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 235.6 W
- Voc @ 25C
- 37.4 V
- Efficiency
- 16.15%
How Does RSI Holding RSI-6M-260M-60 Compare Against Peer CEC Listings?
Engineering position of RSI Holding RSI-6M-260M-60 (260.0 W STC) vs. Anhui Rinengzhongtian Semiconductor Development QJM260-60 across 5,889 CEC Mono-c-Si solar modules.
Ranking #19,146 across 21,677 CEC solar panels (below all-CEC median; higher than 10.4% of peers), RSI Holding RSI-6M-260M-60 operates as a compact residential or specialty off-grid module sitting 150.0 W below the 410.0 W Mono-c-Si median. Lower 37.4 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 90.6% PTC-to-STC thermal output (235.6 W real-world rating), 31 panels occupy 537 sq ft and offset roughly $2,017/yr at average US rates (or $3,411/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does RSI Holding RSI-6M-260M-60 Fall Across Listed CEC Models?
Plots RSI Holding RSI-6M-260M-60 at 260.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define RSI Holding RSI-6M-260M-60?
Benchmarks RSI Holding RSI-6M-260M-60 on STC wattage, thermal PTC/STC retention, and 16.15 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for RSI Holding RSI-6M-260M-60?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for RSI Holding RSI-6M-260M-60 by RSI Holding.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.15% Aperture Efficiency
Power density 161.5 W/m2 (3.76 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.77 V at -10 C (584.8 V string) and 43.02 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 49.9 m2 (537 sq ft) producing 7,304 W PTC; NEC 690.8 OCPD floor is 14.4 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.4 * (1 + (-0.334/100) * (-10 - 25)) = 41.77 V | OCPD = 1.56 * 9.23 = 14.4 A
Inputs from CEC Modules.csv for RSI Holding RSI-6M-260M-60: Voc=37.4 V, beta_Voc=-0.334%/C, Isc=9.23 A, STC=260.0 W, Area=1.61 m2.
Result: 14 panels max on 600 V (584.8 V); 31 panels for 8 kW (537 sq ft).
What Are the Published CEC Specifications for RSI Holding RSI-6M-260M-60?
Laboratory test ratings recorded for RSI Holding RSI-6M-260M-60 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 235.6 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.23 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.7 V / 8.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.334 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.15% (1.61 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many RSI Holding RSI-6M-260M-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (537 sq ft at 8 kW), and estimated Year-1 electric bill offset for RSI Holding RSI-6M-260M-60.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 416 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 537 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 676 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This RSI Holding Series?
Sibling wattage bins and frame colors grouped with RSI Holding RSI-6M-260M-60 under RSI Holding to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| RSI Holding RSI-6M-250M-60 | 250.0 W | 226.3 W | 37.1 V | 31.1 V | 15.53% |
| RSI Holding RSI-6M-255M-60 | 255.0 W | 231.0 W | 37.2 V | 31.3 V | 15.84% |
| RSI Holding RSI-6M-260M-60 | 260.0 W | 235.6 W | 37.4 V | 31.7 V | 16.15% |
| RSI Holding RSI-6M-265M-60 | 265.0 W | 240.3 W | 38.1 V | 31.8 V | 16.46% |
| RSI Holding RSI-6M-270M-60 | 270.0 W | 244.9 W | 38.3 V | 31.9 V | 16.77% |
How Many RSI Holding RSI-6M-260M-60 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for RSI Holding RSI-6M-260M-60 (beta_Voc -0.334%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.02 V | 13 panels | 559.3 V | 23 panels |
| -10 C (14 F) | 41.77 V | 14 panels | 584.8 V | 23 panels |
| 0 C (32 F) | 40.52 V | 14 panels | 567.3 V | 24 panels |
| 25 C (77 F STC) | 37.4 V | 16 panels | 598.4 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to RSI Holding RSI-6M-260M-60?
Closest cross-brand CEC competitors to RSI Holding RSI-6M-260M-60 matched near 260.0 W STC and 37.4 V Voc, led by Anhui Rinengzhongtian Semiconductor Development QJM260-60.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJM260-60 Anhui Rinengzhongtian Semiconductor Development |
260.0 W | Tie (0 W) | 37.39 V | 15.98% | 90.2% |
| Gintung Energy ASEC-260G6S6A Gintung Energy |
260.0 W | Tie (0 W) | 37.42 V | 16.14% | 87.7% |
| CSI Solar Co Ltd CS6P-260P CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.5 V | 16.79% | 92.0% |
| CSI Solar Co Ltd CS6P-260PX CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.5 V | 16.79% | 92.0% |
What Are the Design Limits and Best-Fit Uses for RSI Holding RSI-6M-260M-60?
Evaluate RSI Holding RSI-6M-260M-60 (260.0 W STC, 37.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), RSI Holding RSI-6M-260M-60 reaches 43.02 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 537 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (537 sq ft).
- 2026 tax credit baseline: cash residential installs of RSI Holding RSI-6M-260M-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
RSI Holding RSI-6M-260M-60 8 kW Residential Fit
Needs 31 modules (537 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM260-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 235.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for RSI Holding RSI-6M-260M-60 by RSI Holding grounded in CEC test data and NEC 690.7/690.8 limits.
How many RSI Holding RSI-6M-260M-60 panels fit on a 600 V winter solar string?
At -10 C (14 F), RSI Holding RSI-6M-260M-60 cold Voc rises from 37.4 V to 41.77 V (beta_Voc -0.334%/C), capping a 600 V string at 14 panels (584.8 V).
How much roof area does an 8 kW array of RSI Holding RSI-6M-260M-60 need?
An 8 kW DC system uses 31 RSI Holding RSI-6M-260M-60 modules (8,060 W STC / 7,304 W PTC), covering roughly 537 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does RSI Holding RSI-6M-260M-60 compare against Anhui Rinengzhongtian Semiconductor Development QJM260-60?
RSI Holding RSI-6M-260M-60 outputs 260.0 W STC (37.4 V Voc, rank #19,146 of 21,677), while Anhui Rinengzhongtian Semiconductor Development QJM260-60 delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)