Manufacturer: Renesola America Registry: CEC Verified Engineering Specification

Renesola America JC315M-24/Azs is a 315.0 W STC (285.5 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.23% efficiency, 45.4 V Voc at 25 C, and 50.66 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
285.5 W
Voc @ 25C
45.4 V
Efficiency
16.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Renesola America JC315M-24/Azs Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Renesola America JC315M-24/Azs (Multi-c-Si) residential solar systems.

Renesola America JC315M-24/Azs delivers 162.4 W/m2 (3.68 percentage points below 19.91% CEC median) and typical 90.6% PTC-to-STC thermal output (285.5 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft). At -4 F (-20 C), string voltage climbs to 52.16 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with GCL System Integration Technology Co Ltd GCL-P6/72315 (315.0 W).

Where Does Renesola America JC315M-24/Azs Fall Across Listed CEC Models?

Comparison of Renesola America JC315M-24/Azs (315.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Renesola America JC315M-24/Azs (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRenesola America J: 315.0 W

What Dataset Percentiles Define Renesola America JC315M-24/Azs?

Relative ranking of Renesola America JC315M-24/Azs across nameplate watts, 90.6% PTC thermal ratio, and module aperture efficiency.

Renesola America JC315M-24/Azs Engineering BenchmarksPercentile comparison of Renesola America JC315M-24/Azs wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention90.6%Module Efficiency16.23%

What Do the Dataset Ranks Show for Renesola America JC315M-24/Azs?

Summary of Renesola America JC315M-24/Azs output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,776

16.23% Aperture Efficiency

Power density 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.66 V at -10 C (557.3 V string) and 52.16 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,423 W PTC; NEC 690.8 OCPD floor is 13.85 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.4 * (1 + (-0.331/100) * (-10 - 25)) = 50.66 V | OCPD = 1.56 * 8.88 = 13.85 A

Inputs from CEC Modules.csv for Renesola America JC315M-24/Azs: Voc=45.4 V, beta_Voc=-0.331%/C, Isc=8.88 A, STC=315.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (557.3 V); 26 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for Renesola America JC315M-24/Azs?

Complete CEC test sheet for Renesola America JC315M-24/Azs including Isc (8.88 A), Voc (45.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Renesola America JC315M-24/Azs.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 285.5 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.88 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.3 V / 8.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.331 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.23% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Renesola America JC315M-24/Azs Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Renesola America JC315M-24/Azs.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 418 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 543 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 668 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Renesola America Series?

Related Renesola America power steps and black/silver trims consolidated into this Renesola America JC315M-24/Azs series guide.

Sibling CEC listings grouped into the Renesola America JC315M-24/Azs wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Renesola America JC310M-24/Azs 310.0 W 280.9 W 45.0 V 37.0 V 15.98%
Renesola America JC315M-24/Azs 315.0 W 285.5 W 45.4 V 37.3 V 16.23%
Renesola America JC320M-24/Azs 320.0 W 290.2 W 45.6 V 37.4 V 16.49%

How Many Renesola America JC315M-24/Azs Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Renesola America JC315M-24/Azs (45.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.4V and beta_Voc=-0.331%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.16 V 11 panels 573.8 V 19 panels
-10 C (14 F) 50.66 V 11 panels 557.3 V 19 panels
0 C (32 F) 49.16 V 12 panels 589.9 V 20 panels
25 C (77 F STC) 45.4 V 13 panels 590.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Renesola America JC315M-24/Azs?

Four comparable CEC modules such as GCL System Integration Technology Co Ltd GCL-P6/72315 (315.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/72315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 45.6 V 16.23% 90.5%
CSI Solar Co Ltd CS6U-315P
CSI Solar Co Ltd
315.0 W Tie (0 W) 45.1 V 18.1% 92.3%
Centrosolar America EP72 315BW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
Centrosolar America EP72 315SW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Renesola America JC315M-24/Azs?

Evaluate Renesola America JC315M-24/Azs (315.0 W STC, 45.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Renesola America JC315M-24/Azs reaches 52.16 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
  • 2026 tax credit baseline: cash residential installs of Renesola America JC315M-24/Azs carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Renesola America JC315M-24/Azs 8 kW Residential Fit

Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72315.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 285.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Renesola America JC315M-24/Azs by Renesola America grounded in CEC test data and NEC 690.7/690.8 limits.

How many Renesola America JC315M-24/Azs panels fit on a 600 V winter solar string?

At -10 C (14 F), Renesola America JC315M-24/Azs cold Voc rises from 45.4 V to 50.66 V (beta_Voc -0.331%/C), capping a 600 V string at 11 panels (557.3 V).

How much roof area does an 8 kW array of Renesola America JC315M-24/Azs need?

An 8 kW DC system uses 26 Renesola America JC315M-24/Azs modules (8,190 W STC / 7,423 W PTC), covering roughly 543 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Renesola America JC315M-24/Azs compare against GCL System Integration Technology Co Ltd GCL-P6/72315?

Renesola America JC315M-24/Azs outputs 315.0 W STC (45.4 V Voc, rank #15,387 of 21,677), while GCL System Integration Technology Co Ltd GCL-P6/72315 delivers 315.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.