Renesola America JC265M-24/Bbs is a 265.0 W STC (240.2 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.29% efficiency, 37.7 V Voc at 25 C, and 42.07 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
240.2 W
Voc @ 25C
37.7 V
Efficiency
16.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Renesola America JC265M-24/Bbs Compare Against Peer CEC Listings?

Solar engineering breakdown for Renesola America JC265M-24/Bbs: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 265.0 W STC and 240.2 W PTC, Renesola America JC265M-24/Bbs sits -120.0 W vs all-CEC median (below all-CEC median; higher than 11.7% of peers) among 21,677 listed modules. Power density reaches 162.9 W/m2 (3.62 percentage points below 19.91% CEC median). Lower 37.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer Centrosolar America TM6 265xx rates 265.0 W.

Where Does Renesola America JC265M-24/Bbs Fall Across Listed CEC Models?

Distribution marker showing Renesola America JC265M-24/Bbs (265.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Renesola America JC265M-24/Bbs (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRenesola America J: 265.0 W

What Dataset Percentiles Define Renesola America JC265M-24/Bbs?

Dataset percentiles tracking Renesola America JC265M-24/Bbs power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Renesola America JC265M-24/Bbs Engineering BenchmarksPercentile comparison of Renesola America JC265M-24/Bbs wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention90.6%Module Efficiency16.29%

What Do the Dataset Ranks Show for Renesola America JC265M-24/Bbs?

Benchmark highlights for Renesola America JC265M-24/Bbs covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,670

16.29% Aperture Efficiency

Power density 162.9 W/m2 (3.62 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.07 V at -10 C (589.0 V string) and 43.32 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,446 W PTC; NEC 690.8 OCPD floor is 14.09 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.7 * (1 + (-0.331/100) * (-10 - 25)) = 42.07 V | OCPD = 1.56 * 9.03 = 14.09 A

Inputs from CEC Modules.csv for Renesola America JC265M-24/Bbs: Voc=37.7 V, beta_Voc=-0.331%/C, Isc=9.03 A, STC=265.0 W, Area=1.627 m2.

Result: 14 panels max on 600 V (589.0 V); 31 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for Renesola America JC265M-24/Bbs?

Official CEC datasheet figures for Renesola America JC265M-24/Bbs (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Renesola America JC265M-24/Bbs.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 240.2 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.03 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.6 V / 8.66 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.331 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.29% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Renesola America JC265M-24/Bbs Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Renesola America JC265M-24/Bbs modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 403 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 543 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 665 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This Renesola America Series?

Consolidated Renesola America wattage variants sharing the Renesola America JC265M-24/Bbs mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Renesola America JC265M-24/Bbs wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Renesola America JC260M-24/Bbs 260.0 W 235.6 W 37.6 V 30.5 V 15.98%
Renesola America JC265M-24/Bbs 265.0 W 240.2 W 37.7 V 30.6 V 16.29%
Renesola America JC270M-24/Bbs 270.0 W 244.9 W 38.1 V 31.0 V 16.6%

How Many Renesola America JC265M-24/Bbs Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Renesola America JC265M-24/Bbs (42.07 V at 14 F).

Computed from Voc=37.7V and beta_Voc=-0.331%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.32 V 13 panels 563.2 V 23 panels
-10 C (14 F) 42.07 V 14 panels 589.0 V 23 panels
0 C (32 F) 40.82 V 14 panels 571.5 V 24 panels
25 C (77 F STC) 37.7 V 15 panels 565.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Renesola America JC265M-24/Bbs?

Competing CEC solar panels closest to Renesola America JC265M-24/Bbs in nameplate wattage and Voc, starting with Centrosolar America TM6 265xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TM6 265xx
Centrosolar America
265.0 W Tie (0 W) 38.0 V 16.22% 90.9%
Centrosolar America TM6S 265xx
Centrosolar America
265.0 W Tie (0 W) 38.0 V 16.22% 90.9%
GCL System Integration Technology Co Ltd GCL-P6/60265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.29% 90.5%
GCL System Integration Technology Co Ltd GCL-P6/60B265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.26% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Renesola America JC265M-24/Bbs?

Evaluate Renesola America JC265M-24/Bbs (265.0 W STC, 37.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Renesola America JC265M-24/Bbs reaches 43.32 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
  • 2026 tax credit baseline: cash residential installs of Renesola America JC265M-24/Bbs carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Renesola America JC265M-24/Bbs 8 kW Residential Fit

Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 265xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 240.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Renesola America JC265M-24/Bbs by Renesola America grounded in CEC test data and NEC 690.7/690.8 limits.

How many Renesola America JC265M-24/Bbs panels fit on a 600 V winter solar string?

At -10 C (14 F), Renesola America JC265M-24/Bbs cold Voc rises from 37.7 V to 42.07 V (beta_Voc -0.331%/C), capping a 600 V string at 14 panels (589.0 V).

How much roof area does an 8 kW array of Renesola America JC265M-24/Bbs need?

An 8 kW DC system uses 31 Renesola America JC265M-24/Bbs modules (8,215 W STC / 7,446 W PTC), covering roughly 543 sq ft and saving ~$2,055/yr at 18.54 c/kWh.

How does Renesola America JC265M-24/Bbs compare against Centrosolar America TM6 265xx?

Renesola America JC265M-24/Bbs outputs 265.0 W STC (37.7 V Voc, rank #18,880 of 21,677), while Centrosolar America TM6 265xx delivers 265.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.