Rayzon Solar Limited RS590144TGC is a 590.0 W STC (554.9 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 23.05% efficiency, 53.21 V Voc at 25 C, and 57.61 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 590.0 W
- PTC Wattage
- 554.9 W
- Voc @ 25C
- 53.21 V
- Efficiency
- 23.05%
How Does Rayzon Solar Limited RS590144TGC Compare Against Peer CEC Listings?
How Rayzon Solar Limited Rayzon Solar Limited RS590144TGC handles rooftop heat (554.9 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Rayzon Solar Limited RS590144TGC exhibits 13.83 A short-circuit current, requiring a 21.57 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #1,597 of 21,677 (180.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 35.8 m2 for an 8 kW system (17 panels for 10 kW). Higher 53.21 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Rayzon Solar Limited RS590144TGC Fall Across Listed CEC Models?
Where Rayzon Solar Limited RS590144TGC (590.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Rayzon Solar Limited RS590144TGC?
Percentile placement of Rayzon Solar Limited RS590144TGC across power density (230.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Rayzon Solar Limited RS590144TGC?
Four critical engineering numbers homeowners and solar installers check first when reviewing Rayzon Solar Limited RS590144TGC specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 8.1% STC Output
590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.05% Aperture Efficiency
Power density 230.5 W/m2 (3.14 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.61 V at -10 C (576.1 V string) and 58.86 V at -20 C (10 max).
14 Panels = 8,260 W STC
Occupies 35.8 m2 (386 sq ft) producing 7,769 W PTC; NEC 690.8 OCPD floor is 21.57 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.21 * (1 + (-0.236/100) * (-10 - 25)) = 57.61 V | OCPD = 1.56 * 13.83 = 21.57 A
Inputs from CEC Modules.csv for Rayzon Solar Limited RS590144TGC: Voc=53.21 V, beta_Voc=-0.236%/C, Isc=13.83 A, STC=590.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (576.1 V); 14 panels for 8 kW (386 sq ft).
What Are the Published CEC Specifications for Rayzon Solar Limited RS590144TGC?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Rayzon Solar Limited RS590144TGC.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 590.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 554.9 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.21 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.12 V / 13.08 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.236 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.05% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Rayzon Solar Limited RS590144TGC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Rayzon Solar Limited RS590144TGC (590.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.49 kW | 303 sq ft | $1,624 | $2,747 |
| 8 kW Class | 14 | 8.26 kW | 386 sq ft | $2,067 | $3,496 |
| 10 kW Class | 17 | 10.03 kW | 468 sq ft | $2,510 | $4,245 |
How Many Rayzon Solar Limited RS590144TGC Modules Fit in a Cold-Weather String?
Maximum series module counts for Rayzon Solar Limited RS590144TGC from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.86 V | 10 panels | 588.6 V | 16 panels |
| -10 C (14 F) | 57.61 V | 10 panels | 576.1 V | 17 panels |
| 0 C (32 F) | 56.35 V | 10 panels | 563.5 V | 17 panels |
| 25 C (77 F STC) | 53.21 V | 11 panels | 585.3 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Rayzon Solar Limited RS590144TGC?
Alternative CEC solar modules from competing brands near Rayzon Solar Limited RS590144TGC (590.0 W), including Elin Energy (Sirius PV) ELNSM78M-HC-BF-590.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM78M-HC-BF-590 Elin Energy (Sirius PV) |
590.0 W | Tie (0 W) | 53.83 V | 21.3% | 94.4% |
| Aptos Solar Technology LLC DNA-144-BFN10-590W-DG Aptos Solar Technology LLC |
590.0 W | Tie (0 W) | 52.4 V | 22.87% | 95.0% |
| BLUESUN GROUP LIMITED BSM590M10-72HNH BLUESUN GROUP LIMITED |
590.0 W | Tie (0 W) | 52.4 V | 22.87% | 95.0% |
| FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585 FS GREEN ENERGIES PRIVATE LIMITED |
585.0 W | -5.0 W | 53.1 V | 22.85% | 95.0% |
What Are the Design Limits and Best-Fit Uses for Rayzon Solar Limited RS590144TGC?
Evaluate Rayzon Solar Limited RS590144TGC (590.0 W STC, 53.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Rayzon Solar Limited RS590144TGC reaches 58.86 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Rayzon Solar Limited RS590144TGC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Rayzon Solar Limited RS590144TGC 8 kW Residential Fit
Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM78M-HC-BF-590.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 554.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Rayzon Solar Limited RS590144TGC by Rayzon Solar Limited grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Rayzon Solar Limited RS590144TGC PTC wattage (554.9 W) lower than STC (590.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 554.9 W PTC (94.1% retention) across Rayzon Solar Limited RS590144TGC's 2.56 m2 aperture.
Who should skip Rayzon Solar Limited RS590144TGC on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Rayzon Solar Limited RS590144TGC panels (386 sq ft) leave unusable roof gaps vs. Elin Energy (Sirius PV) ELNSM78M-HC-BF-590.
What is the 1,000 V commercial string limit for Rayzon Solar Limited RS590144TGC?
On 1,000 V commercial inverters at -10 C (57.61 V cold Voc), Rayzon Solar Limited RS590144TGC fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Rayzon Solar Limited RS590144TGC.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)