Skip to main content
WireAndSun
Calculators
CEC PV Module

Rayzon Solar Limited RS525144MBC — CEC Solar Module Specifications

Manufacturer: Rayzon Solar Limited Registry: CEC Verified Engineering Specification

Rayzon Solar Limited RS525144MBC is a 525.0 W STC (492.7 W PTC) Mono-c-Si solar module ranking #4,047 of 21,677 CEC listings (top 19.4%; higher than 80.6% of peers). It delivers 20.51% efficiency, 48.98 V Voc at 25 C, and 52.82 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
525.0 W
PTC Wattage
492.7 W
Voc @ 25C
48.98 V
Efficiency
20.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Rayzon Solar Limited RS525144MBC Compare Against Peer CEC Listings?

Solar engineering breakdown for Rayzon Solar Limited RS525144MBC: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Rayzon Solar Limited and peers, Rayzon Solar Limited RS525144MBC stands 115.0 W above the 410.0 W Mono-c-Si median and strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Sizing 6 kW (12 panels) to 10 kW (20 panels) yields $1,577-$2,628/yr in baseline US bill offset. Higher 48.98 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Rayzon Solar Limited RS525144MBC Fall Across Listed CEC Models?

Distribution marker showing Rayzon Solar Limited RS525144MBC (525.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Rayzon Solar Limited RS525144MBC (525.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRayzon Solar Limit: 525.0 W

What Dataset Percentiles Define Rayzon Solar Limited RS525144MBC?

Dataset percentiles tracking Rayzon Solar Limited RS525144MBC power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Rayzon Solar Limited RS525144MBC Engineering BenchmarksPercentile comparison of Rayzon Solar Limited RS525144MBC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage525.0 WPTC/STC Retention93.8%Module Efficiency20.51%

What Do the Dataset Ranks Show for Rayzon Solar Limited RS525144MBC?

Benchmark highlights for Rayzon Solar Limited RS525144MBC covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,047 / 21,677

Top 19.4% STC Output

525.0 W STC (+140.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,487

20.51% Aperture Efficiency

Power density 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.82 V at -10 C (581.0 V string) and 53.92 V at -20 C (11 max).

8 kW Reference Array

16 Panels = 8,400 W STC

Occupies 41.0 m2 (441 sq ft) producing 7,883 W PTC; NEC 690.8 OCPD floor is 20.53 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.98 * (1 + (-0.224/100) * (-10 - 25)) = 52.82 V | OCPD = 1.56 * 13.16 = 20.53 A

Inputs from CEC Modules.csv for Rayzon Solar Limited RS525144MBC: Voc=48.98 V, beta_Voc=-0.224%/C, Isc=13.16 A, STC=525.0 W, Area=2.56 m2.

Result: 11 panels max on 600 V (581.0 V); 16 panels for 8 kW (441 sq ft).

What Are the Published CEC Specifications for Rayzon Solar Limited RS525144MBC?

Official CEC datasheet figures for Rayzon Solar Limited RS525144MBC (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for Rayzon Solar Limited RS525144MBC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 525.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 492.7 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.98 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.16 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.93 V / 12.56 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.224 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.51% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Rayzon Solar Limited RS525144MBC Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Rayzon Solar Limited RS525144MBC modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.3 kW 331 sq ft $1,577 $2,666
8 kW Class 16 8.4 kW 441 sq ft $2,102 $3,555
10 kW Class 20 10.5 kW 551 sq ft $2,628 $4,444

How Many Rayzon Solar Limited RS525144MBC Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Rayzon Solar Limited RS525144MBC (52.82 V at 14 F).

Computed from Voc=48.98V and beta_Voc=-0.224%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.92 V 11 panels 593.1 V 18 panels
-10 C (14 F) 52.82 V 11 panels 581.0 V 18 panels
0 C (32 F) 51.72 V 11 panels 568.9 V 19 panels
25 C (77 F STC) 48.98 V 12 panels 587.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Rayzon Solar Limited RS525144MBC?

Competing CEC solar panels closest to Rayzon Solar Limited RS525144MBC in nameplate wattage and Voc, starting with AXITEC AC-520MH/144VB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-520MH/144VB
AXITEC
520.0 W -5.0 W 49.0 V 20.31% 93.7%
ELITE Solar ET-M772BH520BB
ELITE Solar
520.0 W -5.0 W 49.0 V 20.31% 93.7%
Chint New Energy Technology Co Ltd CHSM72M-HC-520
Chint New Energy Technology Co Ltd
520.0 W -5.0 W 48.9 V 20.97% 92.5%
IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-520/M
IMPERIAL STAR SOLAR(CAMBODIA) CO LTD
520.0 W -5.0 W 48.88 V 20.31% 93.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Rayzon Solar Limited RS525144MBC?

Evaluate Rayzon Solar Limited RS525144MBC (525.0 W STC, 48.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Rayzon Solar Limited RS525144MBC reaches 53.92 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 441 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Rayzon Solar Limited RS525144MBC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Rayzon Solar Limited RS525144MBC 8 kW Residential Fit

Needs 16 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-520MH/144VB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 492.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Rayzon Solar Limited RS525144MBC by Rayzon Solar Limited grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Rayzon Solar Limited RS525144MBC?

Multiplying Rayzon Solar Limited RS525144MBC's 13.16 A short-circuit current by 1.56 equals 20.53 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Rayzon Solar Limited RS525144MBC pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.82 V cold Voc at 14 F and handles 13.16 A Isc; string inverters cap Rayzon Solar Limited RS525144MBC at 11 panels on 600 V.

Is Rayzon Solar Limited RS525144MBC eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Rayzon Solar Limited RS525144MBC rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.