Skip to main content
WireAndSun
Calculators
CEC PV Module

PT NUSA SOLAR INDONESIA NS435M10T-B54yy — CEC Solar Module Specifications

Manufacturer: PT NUSA SOLAR INDONESIA Registry: CEC Verified Engineering Specification

PT NUSA SOLAR INDONESIA NS435M10T-B54yy is a 435.0 W STC (409.0 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 22.31% efficiency, 39.64 V Voc at 25 C, and 42.98 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
409.0 W
Voc @ 25C
39.64 V
Efficiency
22.31%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT NUSA SOLAR INDONESIA NS435M10T-B54yy Compare Against Peer CEC Listings?

Solar engineering breakdown for PT NUSA SOLAR INDONESIA NS435M10T-B54yy: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 435.0 W STC and 409.0 W PTC, PT NUSA SOLAR INDONESIA NS435M10T-B54yy sits +50.0 W vs all-CEC median (top 33.5%; higher than 66.5% of peers) among 21,677 listed modules. Power density reaches 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). Lower 39.64 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer AE Solar GmbH AE435CMD-108BDE rates 435.0 W.

Where Does PT NUSA SOLAR INDONESIA NS435M10T-B54yy Fall Across Listed CEC Models?

Distribution marker showing PT NUSA SOLAR INDONESIA NS435M10T-B54yy (435.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT NUSA SOLAR INDONESIA NS435M10T-B54yy (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT NUSA SOLAR INDO: 435.0 W

What Dataset Percentiles Define PT NUSA SOLAR INDONESIA NS435M10T-B54yy?

Dataset percentiles tracking PT NUSA SOLAR INDONESIA NS435M10T-B54yy power output, thermal retention ratio, and aperture efficiency against 21,677 models.

PT NUSA SOLAR INDONESIA NS435M10T-B54yy Engineering BenchmarksPercentile comparison of PT NUSA SOLAR INDONESIA NS435M10T-B54yy wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention94.0%Module Efficiency22.31%

What Do the Dataset Ranks Show for PT NUSA SOLAR INDONESIA NS435M10T-B54yy?

Benchmark highlights for PT NUSA SOLAR INDONESIA NS435M10T-B54yy covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,379

22.31% Aperture Efficiency

Power density 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.98 V at -10 C (558.7 V string) and 43.94 V at -20 C (13 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 37.0 m2 (399 sq ft) producing 7,771 W PTC; NEC 690.8 OCPD floor is 21.76 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.64 * (1 + (-0.241/100) * (-10 - 25)) = 42.98 V | OCPD = 1.56 * 13.95 = 21.76 A

Inputs from CEC Modules.csv for PT NUSA SOLAR INDONESIA NS435M10T-B54yy: Voc=39.64 V, beta_Voc=-0.241%/C, Isc=13.95 A, STC=435.0 W, Area=1.95 m2.

Result: 13 panels max on 600 V (558.7 V); 19 panels for 8 kW (399 sq ft).

What Are the Published CEC Specifications for PT NUSA SOLAR INDONESIA NS435M10T-B54yy?

Official CEC datasheet figures for PT NUSA SOLAR INDONESIA NS435M10T-B54yy (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for PT NUSA SOLAR INDONESIA NS435M10T-B54yy.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 409.0 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.64 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.03 V / 13.17 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.241 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.31% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many PT NUSA SOLAR INDONESIA NS435M10T-B54yy Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PT NUSA SOLAR INDONESIA NS435M10T-B54yy modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 294 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 399 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 483 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This PT NUSA SOLAR INDONESIA Series?

Consolidated PT NUSA SOLAR INDONESIA wattage variants sharing the PT NUSA SOLAR INDONESIA NS435M10T-B54yy mechanical and cell layout.

Sibling CEC listings grouped into the PT NUSA SOLAR INDONESIA NS435M10T-B54yy wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PT NUSA SOLAR INDONESIA NS425M10T-B54yy 425.0 W 399.4 W 39.24 V 32.63 V 21.79%
PT NUSA SOLAR INDONESIA NS430M10T-B54yy 430.0 W 404.2 W 39.44 V 32.83 V 22.05%
PT NUSA SOLAR INDONESIA NS435M10T-B54yy 435.0 W 409.0 W 39.64 V 33.03 V 22.31%
PT NUSA SOLAR INDONESIA NS440M10T-B54yy 440.0 W 413.8 W 39.84 V 33.24 V 22.56%
PT NUSA SOLAR INDONESIA NS445M10T-B54yy 445.0 W 418.7 W 40.04 V 33.45 V 22.82%

How Many PT NUSA SOLAR INDONESIA NS435M10T-B54yy Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PT NUSA SOLAR INDONESIA NS435M10T-B54yy (42.98 V at 14 F).

Computed from Voc=39.64V and beta_Voc=-0.241%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.94 V 13 panels 571.2 V 22 panels
-10 C (14 F) 42.98 V 13 panels 558.7 V 23 panels
0 C (32 F) 42.03 V 14 panels 588.4 V 23 panels
25 C (77 F STC) 39.64 V 15 panels 594.6 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to PT NUSA SOLAR INDONESIA NS435M10T-B54yy?

Competing CEC solar panels closest to PT NUSA SOLAR INDONESIA NS435M10T-B54yy in nameplate wattage and Voc, starting with AE Solar GmbH AE435CMD-108BDE.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AE Solar GmbH AE435CMD-108BDE
AE Solar GmbH
435.0 W Tie (0 W) 40.1 V 22.31% 94.9%
DE SOLAR(S) PTE LTD DE435-108BG-182S-N/BB
DE SOLAR(S) PTE LTD
435.0 W Tie (0 W) 40.1 V 22.31% 94.9%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435
Elin Energy (Sirius PV)
435.0 W Tie (0 W) 39.1 V 22.42% 95.0%
Elin Energy (Sirius PV) ELNSM54M-HC-N-435
Elin Energy (Sirius PV)
435.0 W Tie (0 W) 39.1 V 22.42% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT NUSA SOLAR INDONESIA NS435M10T-B54yy?

Evaluate PT NUSA SOLAR INDONESIA NS435M10T-B54yy (435.0 W STC, 39.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT NUSA SOLAR INDONESIA NS435M10T-B54yy reaches 43.94 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 399 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (399 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PT NUSA SOLAR INDONESIA NS435M10T-B54yy carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT NUSA SOLAR INDONESIA NS435M10T-B54yy 8 kW Residential Fit

Needs 19 modules (399 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AE Solar GmbH AE435CMD-108BDE.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 409.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT NUSA SOLAR INDONESIA NS435M10T-B54yy by PT NUSA SOLAR INDONESIA grounded in CEC test data and NEC 690.7/690.8 limits.

How many PT NUSA SOLAR INDONESIA NS435M10T-B54yy panels fit on a 600 V winter solar string?

At -10 C (14 F), PT NUSA SOLAR INDONESIA NS435M10T-B54yy cold Voc rises from 39.64 V to 42.98 V (beta_Voc -0.241%/C), capping a 600 V string at 13 panels (558.7 V).

How much roof area does an 8 kW array of PT NUSA SOLAR INDONESIA NS435M10T-B54yy need?

An 8 kW DC system uses 19 PT NUSA SOLAR INDONESIA NS435M10T-B54yy modules (8,265 W STC / 7,771 W PTC), covering roughly 399 sq ft and saving ~$2,070/yr at 18.54 c/kWh.

How does PT NUSA SOLAR INDONESIA NS435M10T-B54yy compare against AE Solar GmbH AE435CMD-108BDE?

PT NUSA SOLAR INDONESIA NS435M10T-B54yy outputs 435.0 W STC (39.64 V Voc, rank #6,850 of 21,677), while AE Solar GmbH AE435CMD-108BDE delivers 435.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.