Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB is a 455.0 W STC (433.2 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 23.45% efficiency, 40.5 V Voc at 25 C, and 43.69 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 433.2 W
- Voc @ 25C
- 40.5 V
- Efficiency
- 23.45%
How Does Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB Compare Against Peer CEC Listings?
Engineering position of Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB (455.0 W STC) vs. G-Star Pte Ltd GSD7S54T-455BT across 5,889 CEC Mono-c-Si solar modules.
Built with 18 Mono-c-Si cells, Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB pairs strong 95.2% PTC-to-STC heat retention (#399 of 21,677) with 40.5 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,798 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer G-Star Pte Ltd GSD7S54T-455BT offers a 455.0 W alternative.
Where Does Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB Fall Across Listed CEC Models?
Plots Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB?
Benchmarks Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB on STC wattage, thermal PTC/STC retention, and 23.45 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB by Phono Solar Technology Co Ltd.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.45% Aperture Efficiency
Power density 234.5 W/m2 (3.54 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.69 V at -10 C (568.0 V string) and 44.6 V at -20 C (13 max).
18 Panels = 8,190 W STC
Occupies 34.9 m2 (376 sq ft) producing 7,798 W PTC; NEC 690.8 OCPD floor is 21.92 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.5 * (1 + (-0.225/100) * (-10 - 25)) = 43.69 V | OCPD = 1.56 * 14.05 = 21.92 A
Inputs from CEC Modules.csv for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB: Voc=40.5 V, beta_Voc=-0.225%/C, Isc=14.05 A, STC=455.0 W, Area=1.94 m2.
Result: 13 panels max on 600 V (568.0 V); 18 panels for 8 kW (376 sq ft).
What Are the Published CEC Specifications for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB?
Laboratory test ratings recorded for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 433.2 W (95.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.0 V / 13.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.225 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.45% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 18 cells (Mono-c-Si) | Monofacial backsheet |
How Many Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (376 sq ft at 8 kW), and estimated Year-1 electric bill offset for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 292 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 376 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 459 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Phono Solar Technology Co Ltd Series?
Sibling wattage bins and frame colors grouped with Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB under Phono Solar Technology Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Phono Solar Technology Co Ltd PS450M8GFH-18/VNHB | 450.0 W | 428.3 W | 40.3 V | 33.8 V | 23.2% |
| Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB | 455.0 W | 433.2 W | 40.5 V | 34.0 V | 23.45% |
How Many Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB (beta_Voc -0.225%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.6 V | 13 panels | 579.8 V | 22 panels |
| -10 C (14 F) | 43.69 V | 13 panels | 568.0 V | 22 panels |
| 0 C (32 F) | 42.78 V | 14 panels | 598.9 V | 23 panels |
| 25 C (77 F STC) | 40.5 V | 14 panels | 567.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB?
Closest cross-brand CEC competitors to Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB matched near 455.0 W STC and 40.5 V Voc, led by G-Star Pte Ltd GSD7S54T-455BT.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| G-Star Pte Ltd GSD7S54T-455BT G-Star Pte Ltd |
455.0 W | Tie (0 W) | 40.46 V | 23.45% | 95.2% |
| G-Star Pte Ltd GSD7S54T-455WT G-Star Pte Ltd |
455.0 W | Tie (0 W) | 40.46 V | 23.45% | 95.2% |
| AEG SOLAR ENERGY SRL ALPS54D30-455/TP AEG SOLAR ENERGY SRL |
455.0 W | Tie (0 W) | 40.1 V | 22.86% | 94.4% |
| ELITE Solar ET-N754TBH455GB ELITE Solar |
455.0 W | Tie (0 W) | 39.86 V | 23.33% | 95.0% |
What Are the Design Limits and Best-Fit Uses for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB?
Evaluate Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB (455.0 W STC, 40.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB reaches 44.6 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB 8 kW Residential Fit
Needs 18 modules (376 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare G-Star Pte Ltd GSD7S54T-455BT.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 433.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB by Phono Solar Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB?
Multiplying Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB's 14.05 A short-circuit current by 1.56 equals 21.92 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.69 V cold Voc at 14 F and handles 14.05 A Isc; string inverters cap Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB at 13 panels on 600 V.
Is Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)