Philadelphia Solar PS-M72(BF)-405 — CEC Solar Module Specifications

Manufacturer: Philadelphia Solar Registry: CEC Verified Engineering Specification

Philadelphia Solar PS-M72(BF)-405 is a 405.0 W STC (377.8 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.25% efficiency, 50.8 V Voc at 25 C, and 55.55 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
377.8 W
Voc @ 25C
50.8 V
Efficiency
20.25%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Philadelphia Solar PS-M72(BF)-405 Compare Against Peer CEC Listings?

How Philadelphia Solar Philadelphia Solar PS-M72(BF)-405 handles rooftop heat (377.8 W PTC), 8 kW sizing, and cold winter string voltage.

Philadelphia Solar builds the Philadelphia Solar PS-M72(BF)-405 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 202.5 W/m2 (0.34 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF (405.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Higher 50.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 15.72 A overcurrent floor served by a 20 A breaker.

Where Does Philadelphia Solar PS-M72(BF)-405 Fall Across Listed CEC Models?

Where Philadelphia Solar PS-M72(BF)-405 (405.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Philadelphia Solar PS-M72(BF)-405 (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPhiladelphia Solar: 405.0 W

What Dataset Percentiles Define Philadelphia Solar PS-M72(BF)-405?

Percentile placement of Philadelphia Solar PS-M72(BF)-405 across power density (202.5 W/m2), thermal retention, and nameplate STC wattage.

Philadelphia Solar PS-M72(BF)-405 Engineering BenchmarksPercentile comparison of Philadelphia Solar PS-M72(BF)-405 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.3%Module Efficiency20.25%

What Do the Dataset Ranks Show for Philadelphia Solar PS-M72(BF)-405?

Four critical engineering numbers homeowners and solar installers check first when reviewing Philadelphia Solar PS-M72(BF)-405 specifications.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,573

20.25% Aperture Efficiency

Power density 202.5 W/m2 (0.34 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.55 V at -10 C (555.5 V string) and 56.9 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 40.0 m2 (431 sq ft) producing 7,556 W PTC; NEC 690.8 OCPD floor is 15.72 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.8 * (1 + (-0.267/100) * (-10 - 25)) = 55.55 V | OCPD = 1.56 * 10.08 = 15.72 A

Inputs from CEC Modules.csv for Philadelphia Solar PS-M72(BF)-405: Voc=50.8 V, beta_Voc=-0.267%/C, Isc=10.08 A, STC=405.0 W, Area=2.0 m2.

Result: 10 panels max on 600 V (555.5 V); 20 panels for 8 kW (431 sq ft).

What Are the Published CEC Specifications for Philadelphia Solar PS-M72(BF)-405?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Philadelphia Solar PS-M72(BF)-405.

Official California Energy Commission (NREL SAM) test parameters for Philadelphia Solar PS-M72(BF)-405.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 377.8 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.08 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.1 V / 9.62 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.267 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.25% (2.0 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Philadelphia Solar PS-M72(BF)-405 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Philadelphia Solar PS-M72(BF)-405 (405.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 323 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 431 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 538 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Philadelphia Solar Series?

All closely matched Philadelphia Solar wattages and cosmetic trims sharing the Philadelphia Solar PS-M72(BF)-405 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Philadelphia Solar PS-M72(BF)-405 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Philadelphia Solar PS-M72(BF)-400 400.0 W 373.0 W 50.52 V 41.8 V 20.0%
Philadelphia Solar PS-M72(BF)-405 405.0 W 377.8 W 50.8 V 42.1 V 20.25%

How Many Philadelphia Solar PS-M72(BF)-405 Modules Fit in a Cold-Weather String?

Maximum series module counts for Philadelphia Solar PS-M72(BF)-405 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.8V and beta_Voc=-0.267%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.9 V 10 panels 569.0 V 17 panels
-10 C (14 F) 55.55 V 10 panels 555.5 V 18 panels
0 C (32 F) 54.19 V 11 panels 596.1 V 18 panels
25 C (77 F STC) 50.8 V 11 panels 558.8 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M72(BF)-405?

Alternative CEC solar modules from competing brands near Philadelphia Solar PS-M72(BF)-405 (405.0 W), including Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.15% 93.4%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF-DG
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.05% 93.7%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.76% 93.7%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF-DG
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.76% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M72(BF)-405?

Evaluate Philadelphia Solar PS-M72(BF)-405 (405.0 W STC, 50.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M72(BF)-405 reaches 56.9 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 431 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (431 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M72(BF)-405 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Philadelphia Solar PS-M72(BF)-405 8 kW Residential Fit

Needs 20 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 377.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Philadelphia Solar PS-M72(BF)-405 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Philadelphia Solar PS-M72(BF)-405?

Multiplying Philadelphia Solar PS-M72(BF)-405's 10.08 A short-circuit current by 1.56 equals 15.72 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Philadelphia Solar PS-M72(BF)-405 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.55 V cold Voc at 14 F and handles 10.08 A Isc; string inverters cap Philadelphia Solar PS-M72(BF)-405 at 10 panels on 600 V.

Is Philadelphia Solar PS-M72(BF)-405 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Philadelphia Solar PS-M72(BF)-405 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.