Orb Energy Private Limited Orb345M72-15 is a 345.0 W STC (316.6 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 18.25% efficiency, 48.9 V Voc at 25 C, and 54.02 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 345.0 W
- PTC Wattage
- 316.6 W
- Voc @ 25C
- 48.9 V
- Efficiency
- 18.25%
How Does Orb Energy Private Limited Orb345M72-15 Compare Against Peer CEC Listings?
Engineering position of Orb Energy Private Limited Orb345M72-15 (345.0 W STC) vs. GCL System Integration Technology Co Ltd GCL-P6/72345 across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Orb Energy Private Limited Orb345M72-15 pairs strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677) with 48.9 V nominal Voc. An 8 kW residential build (8,280 W DC, 7,598 W PTC) saves ~$2,072/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer GCL System Integration Technology Co Ltd GCL-P6/72345 offers a 345.0 W alternative.
Where Does Orb Energy Private Limited Orb345M72-15 Fall Across Listed CEC Models?
Plots Orb Energy Private Limited Orb345M72-15 at 345.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Orb Energy Private Limited Orb345M72-15?
Benchmarks Orb Energy Private Limited Orb345M72-15 on STC wattage, thermal PTC/STC retention, and 18.25 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Orb Energy Private Limited Orb345M72-15?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Orb Energy Private Limited Orb345M72-15 by Orb Energy Private Limited.
345.0 W STC · Higher Than 37.4%
345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.25% Aperture Efficiency
Power density 182.5 W/m2 (1.66 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.02 V at -10 C (594.2 V string) and 55.48 V at -20 C (10 max).
24 Panels = 8,280 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,598 W PTC; NEC 690.8 OCPD floor is 14.7 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.9 * (1 + (-0.299/100) * (-10 - 25)) = 54.02 V | OCPD = 1.56 * 9.42 = 14.7 A
Inputs from CEC Modules.csv for Orb Energy Private Limited Orb345M72-15: Voc=48.9 V, beta_Voc=-0.299%/C, Isc=9.42 A, STC=345.0 W, Area=1.89 m2.
Result: 11 panels max on 600 V (594.2 V); 24 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for Orb Energy Private Limited Orb345M72-15?
Laboratory test ratings recorded for Orb Energy Private Limited Orb345M72-15 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 316.6 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.42 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.94 V / 8.64 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.299 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.25% (1.89 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Orb Energy Private Limited Orb345M72-15 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (488 sq ft at 8 kW), and estimated Year-1 electric bill offset for Orb Energy Private Limited Orb345M72-15.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.21 kW | 366 sq ft | $1,554 | $2,628 |
| 8 kW Class | 24 | 8.28 kW | 488 sq ft | $2,072 | $3,504 |
| 10 kW Class | 29 | 10.01 kW | 590 sq ft | $2,505 | $4,236 |
How Many Orb Energy Private Limited Orb345M72-15 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Orb Energy Private Limited Orb345M72-15 (beta_Voc -0.299%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.48 V | 10 panels | 554.8 V | 18 panels |
| -10 C (14 F) | 54.02 V | 11 panels | 594.2 V | 18 panels |
| 0 C (32 F) | 52.56 V | 11 panels | 578.2 V | 19 panels |
| 25 C (77 F STC) | 48.9 V | 12 panels | 586.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Orb Energy Private Limited Orb345M72-15?
Closest cross-brand CEC competitors to Orb Energy Private Limited Orb345M72-15 matched near 345.0 W STC and 48.9 V Voc, led by GCL System Integration Technology Co Ltd GCL-P6/72345.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-P6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 47.3 V | 17.78% | 91.6% |
| AXITEC AC-345M/156-72S AXITEC |
345.0 W | Tie (0 W) | 47.0 V | 17.78% | 91.4% |
| GCL System Integration Technology Co Ltd GCL-P3/72H345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.88 V | 17.16% | 93.1% |
| GCL System Integration Technology Co Ltd GCL-M6/72345 GCL System Integration Technology Co Ltd |
345.0 W | Tie (0 W) | 46.8 V | 17.78% | 90.5% |
What Are the Design Limits and Best-Fit Uses for Orb Energy Private Limited Orb345M72-15?
Evaluate Orb Energy Private Limited Orb345M72-15 (345.0 W STC, 48.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Orb Energy Private Limited Orb345M72-15 reaches 55.48 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (488 sq ft).
- 2026 tax credit baseline: cash residential installs of Orb Energy Private Limited Orb345M72-15 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Orb Energy Private Limited Orb345M72-15 8 kW Residential Fit
Needs 24 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72345.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 316.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Orb Energy Private Limited Orb345M72-15 by Orb Energy Private Limited grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Orb Energy Private Limited Orb345M72-15?
Multiplying Orb Energy Private Limited Orb345M72-15's 9.42 A short-circuit current by 1.56 equals 14.7 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Orb Energy Private Limited Orb345M72-15 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.02 V cold Voc at 14 F and handles 9.42 A Isc; string inverters cap Orb Energy Private Limited Orb345M72-15 at 11 panels on 600 V.
Is Orb Energy Private Limited Orb345M72-15 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Orb Energy Private Limited Orb345M72-15 rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)